14
PARAMETER LIST
45
Second deceleration time
0 to 3600s,
9999
9999
46
Second torque boost
0 to 30%,
9999
9999
47
Second V/F (base frequency)
0 to 400Hz,
9999
9999
48
Second stall prevention
operation current
0 to 200%,
9999
9999
51
Second electronic thermal O/L
relay
0 to 500A,
9999
9999
52
DU/PU main display data
selection
0, 5, 8 to 12,
14, 20, 23 to
25, 52 to 55,
61, 62, 64,
100
0
55
Frequency monitoring
reference
0 to 400Hz
50Hz
56
Current monitoring reference
0 to 500A
Rated
inverter
current
57
Restart coasting time
0, 0.1 to 5s,
9999
9999
58
Restart cushion time
0 to 60s
1s
59
Remote function selection
0, 1, 2, 3
0
60
Energy saving control
selection
0, 9
0
65
Retry selection
0 to 5
0
66
Stall prevention operation
reduction starting frequency
0 to 400Hz
50Hz
67
Number of retries at fault
occurrence
0 to 10, 101
to 110
0
68
Retry waiting time
0.1 to 600s
1s
69
Retry count display erase
0
0
70
Special regenerative brake
duty
0 to 30%
0%
71
Applied motor
0, 1, 3, 13,
23, 40, 43,
50, 53
0
72
PWM frequency selection
0 to 15
1
73
Analog input selection
0, 1, 10, 11
1
74
Input filter time constant
0 to 8
1
75
Reset selection/disconnected
PU detection/PU stop
selection
0 to 3, 14 to
17
14
77
Parameter write selection
0, 1, 2
0
78
Reverse rotation prevention
selection
0, 1, 2
0
79
Operation mode selection
0, 1, 2, 3, 4,
6, 7
0
80
Motor capacity
0.1 to 7.5kW,
9999
9999
82
Motor excitation current
0 to 500A,
9999
9999
83
Motor rated voltage
0 to 1000V
200V/
400V
∗5
84
Rated motor frequency
10 to 120Hz
50Hz
Parameter
Name
Setting
Range
Initial
Value
90
Motor constant (R1)
0 to 50
Ω
,
9999
9999
96
Auto tuning setting/status
0, 11, 21
0
117
PU communication station
number
0 to 31 (0 to
247)
0
118
PU communication speed
48, 96, 192,
384
192
119
PU communication stop bit
length
0, 1, 10, 11
1
120
PU communication parity
check
0, 1, 2
2
121
Number of PU communication
retries
0 to 10, 9999
1
122
PU communication check time
interval
0, 0.1 to
999.8s,
9999
0
123
PU communication waiting
time setting
0 to 150ms,
9999
9999
124
PU communication CR/LF
selection
0, 1, 2
1
125
Terminal 2 frequency setting
gain frequency
0 to 400Hz
50Hz
126
Terminal 4 frequency setting
gain frequency
0 to 400Hz
50Hz
127
PID control automatic
switchover frequency
0 to 400Hz,
9999
9999
128
PID action selection
0, 20, 21, 40
to 43
0
129
PID proportional band
0.1 to
1000%, 9999
100%
130
PID integral time
0.1 to 3600s,
9999
1s
131
PID upper limit
0 to 100%,
9999
9999
132
PID lower limit
0 to 100%,
9999
9999
133
PID action set point
0 to 100%,
9999
9999
134
PID differential time
0.01 to
10.00s, 9999
9999
145
PU display language selection 0 to 7
1
146
Parameter for manufacturer setting. Do not set.
150
Output current detection level 0 to 200%
150%
151
Output current detection signal
delay time
0 to 10s
0s
152
Zero current detection level
0 to 200%
5%
153
Zero current detection time
0 to 1s
0.5s
156
Stall prevention operation
selection
0 to 31, 100,
101
0
157
OL signal output timer
0 to 25s,
9999
0s
158
AM terminal function selection
1 to 3, 5, 8 to
12, 14, 21,
24, 52, 53,
61, 62
1
160
Extended function display
selection
0, 9999
9999
161
Frequency setting/key lock
operation selection
0, 1, 10, 11
0
Parameter
Name
Setting
Range
Initial
Value
D700_EC_Guideline_ib0600352ENG.book 14 ページ 2008年4月10日 木曜日 午後2時6分