6
GB
Technical Information
3
Product specification
Model name
EHSC-VM6B
EHSC-YM9B
EHSC-VM6EB
EHSC-YM9EB
EHPX-VM2B
EHPX-VM6B
EHPX-YM9B
ERSC-VM2B
Overall unit dimensions
(Height×Width×Depth)
800×530×360 mm
860×530×360 mm
W
eight (empty)
53 kg
53 kg
49 kg
49 kg
39 kg
4
kg
4
kg
54 kg
W
eight (full)
59 kg
59 kg
55 kg
55 kg
44 kg
46 kg
46 kg
60 kg
Plate heat exchanger
—
—
—
Cooling mode
NOT
available
Available
Unvented expansion vessel
(Primary circuit)
Nominal volume
10 L
-
10 L
Charge pressure
0.1 MPa (1 bar)
-
0.1 MPa (1 bar)
Safety
device
W
ater circuit
(Primary)
Control thermistor
1 - 80°C
Pressure relief valve
0.3 MPa (3 bar)
Flow switch
Min flow 5.5 L/min
Booster heater
Manual reset thermostat
90°C
Thermal cut-out (for dry run prevention)
121°C
Primary circuit circulating pump
Grundfos UPM2 25 70-180
Connections
W
ater
28 mm compression (Primary circuit)
G1 (Male)
Refrigerant
(R410A)
Liquid
9.52 mm
—
9.52 mm
Gas
5.88 mm
—
5.88 mm
Target temperature range
Flow temperature
Heating
25 - 60°C
Cooling
—
5 - 25°C
Room temperature
Heating
10 - 30°C
Cooling
—
Not available
Guaranteed operating range
Ambient
*
0 - 35°C (≤ 80%RH)
Outdoor temperature
Heating
See outdoor unit spec table.
Cooling
—
See outdoor unit
spec table (min.
10 °C). *2
Electrical data
Control board
Power supply
(Phase, voltage,
frequency)
~/N, 230V
, 50Hz
Breaker
(*when powered from
independent source)
10A
Booster heater
Power supply
(Phase, voltage,
frequency)
~N, 230V
, 50Hz
3~, 400V
, 50Hz
~N, 230V
, 50Hz
3~, 400V
, 50Hz
~N, 230V
, 50Hz
~N, 230V
, 50Hz
3~, 400V
, 50Hz
~N, 230V
, 50Hz
Capacity
2kW + 4kW
3kW + 6kW
2kW + 4kW
3kW + 6kW
2kW
2kW + 4kW
3kW + 6kW
2kW
Current
26A
3A
26A
3A
9A
26A
3A
9A
Breaker
32A
6A
32A
6A
6A
32A
6A
6A
<T
able 3.1>
Optional extras
• Wireless Remote Controller
PAR-WT50R-E
• Joint pipe (15.88 → 12.7)
PAC-SH50RJ-E
• Wireless Receiver
PAR-WR51R-E
• Joint pipe (9.52 → 6.35)
PAC-SH30RJ-E
• Remote sensor
PAC-SE5
TS-E
• Thermistor
PAC-TH01
1-E
• T
ank thermistor (THW5)
PAC-TH01
1TK-E
• High temperature thermistor
PAC-TH01
1HT
-E
*
The environment must be frost-free.
*2 Low ambient cooling is NOT
allowed.