60
Service and Maintenance
7
GB
Engineers Forms (1/2)
Should settings be changed from default, please enter and record new setting in ‘Field Setting’ column. This will ease resetting in the future should the system use change
or the circuit board need to be replaced.
Commissioning/Field settings record sheet
Main controller screen
Parameters
Default setting Field
setting Notes
Main
Zone1 heating room temp
10°C - 30°C
20°C
Zone2 heating room temp *1
10°C - 30°C
20°C
Zone1 heating flow temp
25°C - 60°C
45°C
Zone2 heating flow temp *1
25°C - 60°C
35°C
Cooling flow temp *2
5°C - 25°C
15°C
Zone1 heating compensation curve
−9°C - + 9°C
0°C
Zone2 heating compensation curve *1
−9°C - + 9°C
0°C
Holiday mode
Active/Non active/Set time
–
Option
Forced DHW operation
On/Off
–
DHW
On/Off/Timer
On
Heating
On/Off/Timer
On
Holiday mode
Active/Non active/Set time
–
Setting
DHW *3
Operation mode
Normal/Eco
Normal
DHW max. temp.
40°C - 60°C
50°C
DHW temp. drop
5°C - 30°C
10°C
DHW max. operation time
30 - 120 mins
60 mins
DHW mode restriction
30 - 120 mins
30 mins
Legionella prevention *3
Active
Yes/No
Yes
Hot water temp
60°C - 70°C
65°C
Frequency
1 - 30 days
15 days
Start time
00.00 - 23.00
03.00
Max. operation time
1 - 5 hours
3 hours
Duration of maximum temp.
1 - 120 mins
30 min
Heating/Cooling *2
Zone1 operation mode
Heating room temp/Heating flow temp/Heating
compensation curve/Cooling flow temp
Room temp
Zone2 operation mode *1
Heating room temp/Heating flow temp/Heating
compensation curve
Compensation
curve
Compensation
curve
Hi set point
Zone1 outdoor ambient temp
−15°C - +35°C
–15°C
Zone1 flow temp
25°C – 60°C
50°C
Zone2 outdoor ambient temp *1
−15°C - +35°C
–15°C
Zone2 flow temp *1
25°C - 60°C
40°C
Lo set point
Zone1 outdoor ambient temp
−15°C - +35°C
35°C
Zone1 flow temp
25°C - 60°C
25°C
Zone2 outdoor ambient temp *1
−15°C - +35°C
35°C
Zone2 flow temp *1
25°C - 60°C
25°C
Adjust
Zone1 outdoor ambient temp
−14°C - +34°C
—
Zone1 flow temp
25°C - 60°C
—
Zone2 outdoor ambient temp *1
−14°C - +34°C
—
Zone2 flow temp *1
25°C - 60°C
—
Holiday
DHW *3
Active/Non active
Non active
Heating/Cooling *2
Active/Non active
Active
Zone1 heating room temp
10°C - 30°C
15°C
Zone2 heating room temp *1
10°C - 30°C
15°C
Zone1 heating flow temp
25°C - 60°C
35°C
Zone2 heating flow temp *1
25°C - 60°C
25°C
Cooling flow temp *2
5°C - 25°C
25°C
Initial settings
Language
ENG/FR/GER/SW/SP/IT/DA/NL/FIN/NOR/PT
ENG
°C/°F
°C/°F
°C
Temp. display
Room/DHW tank/Room&DHW tank /Off
Off
Time display
hh:mm/hh:mm AM/AM hh:mm
hh:mm
Room sensor settings for Zone1
TH1/Main RC/Room RC1-8/“Time/Zone”
TH1
Room sensor settings for Zone2 *1
TH1/Main RC/Room RC1-8/“Time/Zone”
TH1
Room RC zone select *1
Zone1/Zone2
Zone1
Service menu
Thermistor
adjustment
THW1
−10°C - +10°C
0°C
THW2
−10°C - +10°C
0°C
THW5
−10°C - +10°C
0°C
THW6
−10°C - +10°C
0°C
THW7
−10°C - +10°C
0°C
THW8
−10°C - +10°C
0°C
THW9
−10°C - +10°C
0°C
THWB1
−10°C - +10°C
0°C
THWB2
−10°C - +10°C
0°C
Auxiliary settings Economy settings
for pump
On/Off
On
Time before pump switched off (3 - 60 mins) *4
10 mins
Electric heater
(Heating)
Space heating: On (used)/Off (not used)
On
Electric heater delay timer (5 - 180 mins)
30 mins
Electric heater
(DHW) *3
DHW: On (used)/Off (not used)
On
Electric heater delay timer (15 - 30 mins)
15 mins
Mixing valve
control
Running time (10 - 240 secs)
120 secs
Interval (1 - 30 mins)
2 mins
Pump speed
Pump speed (1 - 5)
5
*1 The settings related to Zone2 can be switched only when Zone2 temperature control is enabled (when Dip SW2-6 and SW 2-7 are ON).
*2 Cooling mode settings are available for ERSC-VM2B only.
*3 Only available if DHW tank present in system.
*4 Decreasing “time before pump switched off” may increase the duration of stand-by in Heating mode.