13
OCH714D
No.
Part name
ERST20C-
*M*D
ERST30C-
*M*ED
EHPT17/20X-
*M*D
EHPT20/30X-
*M*ED
EHPT20/30X-
MED
ERPT17/20X-
*M*D
ERPT20X-
MD
ERPT30X-
VM*ED
EHPT20X-
MHEDW
A DHW outlet pipe
B
Cold water inlet pipe
C
Water pipe (Space heating/cooling return connection)
D
Water pipe (Space heating/cooling flow connection)
E
Water pipe (Flow from heat pump connection)
—
—
F Water pipe (Return to heat pump connection)
—
—
G Refrigerant pipe (Gas)
—
—
—
—
—
—
—
H Refrigerant pipe (Liquid)
—
—
—
—
—
—
—
1
Control and electrical box
2 Main remote controller
3
Plate heat exchanger (Refrigerant - Water)
—
—
—
—
—
—
—
4 Booster heater 1,2
—
—
—
5
3-way valve
6 Drain cock (Primary circuit)
7 Manometer
8 Pressure relief valve (3 bar)
*2
*3
—
—
—
—
—
—
—
9 Automatic air vent
10
Expansion vessel (Primary circuit)
—
—
—
—
—
11
Flow sensor
12 Strainer valve
13 Water circulation pump 1 (Primary circuit)
14 Pump valve
15 DHW tank
16
Plate heat exchanger (Water - Water)
17 Scale trap
18 Water circulation pump (Sanitary circuit)
19 Immersion heater
—
—
—
—
—
—
—
—
20 Temperature and pressure relief valve
—
—
—
—
—
—
—
—
21 Pressure relief valve (10 bar) (DHW Tank)
—
22 Drain cock (DHW tank)
23 Drain cock (Sanitary circuit)
24
Flow water temp. thermistor (THW1)
25
Return water temp. thermistor (THW2)
26
DHW tank upper water temp. thermistor (THW5A)
27
DHW tank lower water temp. thermistor (THW5B)
28 Refrigerant liquid temp. thermistor (TH2)
—
—
—
—
—
—
—
29 Pressure sensor
—
—
—
—
—
—
—
—
—
30 Drain pan
—
—
—
—
31 Outdoor unit
—
—
—
—
—
—
—
—
—
32 Drain pipe (Local supply)
—
—
—
—
—
—
—
—
—
33
Back flow prevention device (Local supply)
—
—
—
—
—
—
—
—
—
34 Isolating valve (Local supply)
—
—
—
—
—
—
—
—
—
35
Magnetic filter (Local supply) (Recommended)
—
—
—
—
—
—
—
—
—
36 Strainer (Local supply)
—
—
—
—
—
—
—
—
—
37 Pressure relief valve (3bar - In outdoor unit)
—
—
38 Inlet control group *1
—
—
—
—
—
—
—
—
—
39
Filling loop (Ball valves, check valves and flexible hose) *1
—
—
—
—
—
—
—
—
—
40
Potable expansion vessel *1
—
—
—
—
—
—
—
—
—
41 Air vent (Local supply)
—
—
—
—
—
—
—
—
—
42 Pressure relief valve (5 bar)
—
—
—
—
—
43 Water circulation pump 2 (Zone1)
—
—
—
—
—
—
—
—
—
44 Water circulation pump 3 (Zone2)
—
—
—
—
—
—
—
—
—
45
Mixing valve
—
—
—
—
—
—
—
—
—
46
Magnetic filter
—
—
—
—
—
—
—
—
—
47 Mud trap
—
—
—
—
—
—
—
—
—
48
Flow zone1 water temp. thermistor (THW6)
—
—
—
—
—
—
—
—
—
49
Return zone1 water temp. thermistor (THW7)
—
—
—
—
—
—
—
—
—
50
Flow zone2 water temp. thermistor (THW8)
—
—
—
—
—
—
—
—
—
51
Return zone2 water temp. thermistor (THW9)
—
—
—
—
—
—
—
—
—
52 Header
—
—
—
—
—
—
—
—
—
*1 Supplied with UK model ONLY. Please refer to PAC-WK02UK-E Installation Manual for more information on accessories.
*2 Attachment the part to the position of 3 bar PRV for E*ST20 series. (Refer to the Figure 3,2 and 3,3 on the manual of RG79F364H01(page 8))
*3 Attachment the part to the position of 3 bar PRV for E*ST30 series. (Refer to the Figure 3,2 and 3,3 on the manual of RG79F364H01(page 8))
<Table 4.2>