8
OCH714D
<T
able 3.2>
*1 V
olume of sanitary water circuit, primary DHW circuit (from 3-way valve to confluent point with heating circuit), piping to expansion vessel, and expansion vessel are not included in this value.
*2
The environment must be frost-free.
*3
See outdoor unit spec table (min, 10
°C
). Cooling mode is not available in low outdoor temperature. If you use our system in cooling mode at the low ambient temperature (10°C or below), there are some risks of plate heat exchanger damages by frozen water
.
*4 For the model without booster heater and immersion heater
, the maximum allowable hot water temperature is [Maximum outlet water of outdoor unit -3
°C]. For the maximum outlet water of outdoor unit, refer to outdoor unit data book.
*5
Do not fit immersion heaters without thermal cut-out. Use only Mitsubishi Electric service parts as a direct replacement.
Model name
EHST30D-
MED
EHST30D- VM6ED
EHST30D- YM9ED
EHST30D- TM9ED
ERST30D- VM2ED
ERST30D- VM6ED
ERST30D- YM9ED
EHST20C-
MED
EHST20C-
VM2D
EHST20C-
VM6D
EHST20C-
YM9D
EHST20C- YM9ED
EHST20C-
TM9D
ERST20C-
VM2D
ERST20C-
VM6D
ERST20C-
YM9D
Nominal domestic hot water volume
300 L
200 L
Overall unit dimensions (Height × Width × Depth)
2050 × 595 × 680 mm
1600 × 595 × 680 mm
W
eight (empty)
113 kg
115 kg
117 kg
115 kg
116 kg
117 kg
103 kg
110 kg
110 kg
112 kg
107 kg
112 kg
110 kg
111
k
g
112 kg
W
eight (full)
420 kg
422 kg
426 kg
422 kg
423 kg
426 kg
310 kg
317 kg
318 kg
322 kg
316 kg
322 kg
317 kg
318 kg
322 kg
W
ater volume of heating circuit in the unit *1
3.9 L
3.9 L
6.2 L
3.9 L
6.2 L
4.6 L
6.9 L
6.9 L
4.6 L
4.6 L
6.9 L
Unvented expansion
vessel(Primary heating)
Nominal volume
—
—
12 L
—
12 L
Charge pressure
—
—
0.1 MPa
—
0.1 MPa
Safety device
Primary circuit
Control thermistor
80°C
Pressure relief valve
0.3 MPa (3 bar)
Flow sensor
Min. flow 5.0 L/min
BH manual reset thermostat
—
90°C
—
90°C
BH thermal Cut Of
f
—
121°C
—
121°C
DHW tank
Control thermistor
75
°C
IH manual reset thermostat
—
Temperature /
Pressure relief valve
1.0 MPa (10 bar)
Connections
W
ater
Primary circuit
ø28 mm
DHW circuit
ø22 mm
Refrigerant
(R32/ R410A)
Liquid
6.35 mm
9.52 mm
Gas
12.7 mm
15.88 mm
Operating range
Heating
Room temperature
10 - 30°C
Flow temperature
20 - 60°C
Cooling
Room temperature
—
Flow temperature
—
5 - 25 °C
—
5 - 25°C
Guaranteed operat
-
ing range *2
Ambient
0 - 35°C (
80 %RH)
Outdoor temperature
Heating
See outdoor unit spec table.
Cooling
—
*3
—
*3
DHW tank performance
Maximum allowable hot water temperature
*4
70°C
*4
70°C
Declared load profile
XL
L
Average climate
W
ater heater energy
efficiency class
A
or A+
A+
Electrical data
Control board (Including 4 pumps)
Power supply
(Phase, voltage, frequency)
~/N, 230 V
, 50 Hz
Input
0.30 kW
Current
1.95 A
Breaker
10 A
Booster heater
Power supply
(Phase, voltage, frequency)
—
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
3~, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
—
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
3~, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
Capacity
—
2 kW +4 kW
3 kW +6 kW
2 kW
2 kW +4 kW
3 kW +6 kW
—
2 kW
2 kW +4 kW
3 kW + 6 kW
3 kW+6 kW
2 kW
2 kW +4 kW
3 kW +6 kW
Heater step
—
3
1
3
—
1
3
3
1
3
Current
—
26 A
13 A
23 A
9 A
26 A
13 A
—
9 A
26 A
13 A
23 A
9 A
26 A
13 A
Breaker
—
32 A
16 A
32A
16 A
32 A
16 A
—
16 A
32 A
16 A
32 A
16 A
32 A
16 A
Immersion heater *5
Power supply
(Phase, voltage, frequency)
—
Capacity
—
Current
—
Breaker
—
Sound power level (PWL)
41 dB(A)
40 dB(A)