Display the operation status screen
Hold down the [
], [
], and [ENTER] buttons on the projector together to
display the picture shown on the right.
Alternatively, open the OPTION menu from the menu screen and move the
cursor to [MENU POSITION]. Press the [AUTO POSITION], [ENTER], and
[AUTO POSITION] buttons in order to display the picture shown on the right.
Press the [MENU] button to cancel this picture.
S/W VERSION
: The software’s version
SET TIME (total) : Projector operating time (Cumulative projector operating
time), impossible to reset.
LAMP TIME (total) :Lamp operating time, possible to reset.
(STANDARD mode time + LOW mode time)
LAMP TIME (LOW) :The total lamp operating time is displayed on a Low mode basis.
(LOW mode time converted from STANDARD mode time
+ LOW mode time) Possible to reset.
LAMP RESET
: Number of times the lamp operating time has been reset,
impossible to reset.
V-FREQ
: Vertical frequency of the input signal
H-FREQ
: Horizontal frequency of the input signal
TEMP ERROR TIME : Time when a temperature error occurred.
0H0M is displayed when the power hasn’t been turned off
because of a temperature error.
(ERROR MODE) : The sensor that caused power-off is indicated within the
parentheses.
(ERROR LAMP MODE) : The lamp mode when an error occurred is indicated within
the parentheses.
IN-TEMP
(*1)
: Intake temperature (°C)
*1)
The figures in the parentheses are the “temperature when the
power is turned off due to a temperature failure”. The default value 0
is shown in the parentheses when the warning record has been
reset. Table 1 shows the temperature setting for each sensor.
LAMP-TEMP
: Lamp temperature (N/A is displayed because this
projector has no LAMP sensor.)
DMD-TEMP
: DMD temperature (N/A is displayed because this projector
has no DMD sensor.)
FAN MODE
: Rotation speed of the fan (0 to 24)
SERVICE COMMANDS
SENSOR
Warning
indication at
Forced
power-off at
Power-on
at
IN TEMP
45 °C
46 °C
41 °C
Table 1 TEMPERATURE SETTING FOR EACH SENSOR
S/W VERSION
1.00 XD430
SET TIME (total)
519H 04M
LAMP TIME (total)
519H 04M
LAMP TIME (LOW)
519H 04M
LAMP RESET
1
V-FREQ
60 Hz
H-FREQ
48.4 kHz
TEMP ERROR TIME
1000H 20M
(ERROR MODE)
(ERROR LAMP MODE)
IN-TEMP
25.0
(43.0 ˚C)
LAMP-TEMP
N/A
(N/A)
DMD-TEMP
N/A
(N/A)
FAN MODE
0
(25)
MENU
Finish
Following are the reference of the life times of the consumable parts.
• Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max.
4,000 hours (When LAMP MODE is LOW.)
• CW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Approx. 8,000 hours
• Cooling fan . . . . . . . . . . . . . . . . . . . . . . . . . . . Approx. 5,000 hours
• Cooling fan (optical) . . . . . . . . . . . . . . . . . . . . Approx. 10,000 hours
LIFE TIME OF THE CONSUMABLE PARTS