- 2 -
Adjustment with Microsoft
®
Windows
®
98/Me/XP operating system
1. Starting
1. Start Windows
98/Me/XP.
2. Select [Start] - [Programs] - [Accessories] -
[Communications] - [Hyper Terminal] in order to
display the Hyper Terminal window.
2. Hyper terminal setting
1. Double-click [hypertrm.exe] on the Hyper
Terminal window.
[Connection Properties] window will open.
Set this window as shown on the right.
2. Click [Call] in the communication menu of the
window to access this projector.
3. Adjustment
Enter the adjustment command and the adjustment
value on the Hyper Terminal window in capital
alphanumeric letters with keyboard and press the
enter key.
4. Writing the adjustment value
The adjustment value entered using the above-
mentioned procedure will be saved in EEPROM
automatically.
5. Close the window
Click the closing button placed at the upper right-
hand corner of the window to close the Hyper
Terminal.
Close all the opening windows before closing
Windows
98/Me/XP.
Item
Setting
Connect using
Port (COM1-COM4)
Port settings
: Bits per second
9600
: Data bits
8 bit
: Parity
None
: Stop bits
1
: Flow control
None
Settings
: Emulation
VT100
ASCII setup
: ASCII Sending
Send line ends with line feeds
Echo typed characters locally
Line delay
: 1000 milliseconds
Character delay : 10 milliseconds
: ASCII Receiving
Append line feeds to incoming line ends