IV
Outlines and Dimensions ]
- 7 -
HWE08010
GB
IV
Outlines and Dimensions
[1] Outlines and Dimensions
1. PEFY-P06,08,12,15,18,24NMSU-E
mm(in.)
(35-7/16)
(27-9/16)
(19-11/16)
(41-3/4)
(33-7/8)
(26)
(47-1/4)
(39-3/8)
(31-1/2)
(39-3/8)
(31-1/2)
(23-5/8)
(41-3/4)
(33-7/8)
(26)
(47-3/16)
(39-5/16)
(31-7/16)
(45-3/8)
(37-1/2)
(29-5/8)
(43-5/16)
(35-7/16)
(27-9/16)
700
Drain pipe(O.D.ø32(1-1/4))
(Emergency draining)
*2
*1
ø6.35(1/4)
ø12.7(1/2)
PEFY-P18NMSU-E
900
952
998
860
9
800
1000
860
7
700
20
24
16
L
900
500
(48-25/32)
(40-29/32)
(33-1/16)
1039
1239
839
(46-7/8)
(39)
(31-1/8)
990
1190
790
KM
N
9
5
J
1060
660
H
800
600
7
660
798
752
Knockout hole ø27(1-3/32)
(Transmission wiring)
Knockout hole ø27(1-3/32)
(Power source wiring)
G
1200
F
1000
E
11
D
1060
C
1100
B
1152
PEFY-P06,08,12NMSU-E
PEFY-P15NMSU-E
PEFY-P24NMSU-E
Model
A
1198
Gas pipe
Liquid pipe
*1
*2
ø12.7(1/2)
ø15.88(5/8)
ø6.35(1/4)
ø9.52(3/8)
ø9.52(3/8)
ø15.88(5/8)
L-ø2.9(1/8)
2x2-ø2.9(1/8)
2xE-ø2.9(1/8)
Control box
Air filter
Suspension bolt hole
4-14x30(9/16x1-3/16) Slot
Terminal bed(Power source)
Refrigerant piping
brazing connection (liquid)
2
Refrigerant piping
brazing connection (gas)
1
Drain pipe(O.D.ø32(1-1/4))
(Spontaneous draining)
Terminal bed(Transmission)
Drain pump
Drain pipe(O.D.ø32(1-1/4))
Air
inlet
Air
outlet
(1-31/32~5-29/32)
159(6-9/32)
345
(13-19/32)
(21-21/32)
(11-13/16)
(30-19/32)
(17-23/32)
(11-13/16)
(17-23/32)
More than 300
(13/16)
(13/32)
(3-9/16)
(5-29/32)
(2-25/32)
(4-19/32)
70
10
(13/32)
(3-15/16)
(1-15/16)
(24-5/8)
450
37
(1-15/32)
200(7-7/8)
H
20(13/16)
157.5
(6-7/32)
20
(13/16)
100
(3-15/16)
37
(1-15/32)
12
(1/2)
12(1/2)
88(3-15/32)
100(3-15/16)xJ=K
100(3-15/16)
88(3-15/32)
777
50
(1-31/32)
50~150
50(1-31/32)
G
450
Less than 550
Less than 300
175
±
5(6-29/32
±
7/32)
10
(13/32)
49
25(1)
More than 20
More than 10
170(6-23/32)
102(4-1/32)
48(1-29/32)
270
(10-21/32)
116
150(Duct)
23(29/32)
100
25(1)
700
(27-9/16)
677
(26-21/32)
23
(29/32)
C
M
B (Suspension bolt pitch)
23(29/32)
A
N
90
625
(Suspension bolt pitch)
100(3-15/16)
57(2-1/4)
D (Duct)
30(1-3/16)
100(3-15/16)x(E-1)=F
100(3-15/16)
20(13/16)
15
(19/32)
<accessory>
Drain hose (I.D.ø32(1-1/4))
(Actual length)
Note2
Access door
Required space for service and maintenance
Access door
Ceiling surface
Make the access door at the appointed
position properly for service maintenance.
Note
1.
Use M10 screw for the Suspension bolt (field supply).
2.
Keep the service space for the maintenance at the bottom.
3.
This chart indicates for PEFY-P15·18NMSU-E models,which
has 3 fans.
PEFY-P06~12NMSU-E models have 2 fans.
PEFY-P24NMSU-E model have 4 fans.
4.
In case of the inlet duct is used,remove the air filter(supply with
the unit), then install the filter(field supply) at suction side.
*1:R410A outdoor unit
*2:R22 outdoor unit
12
Unit : mm(in)