background image

4

GB

Contents

u

  Before operating the unit, make sure you read all the “Safety 

precautions”.

u

  “Safety precautions” lists important points about safety. 

Please be sure to follow them.

Symbols used in the text

 Warning:

Describes precautions that should be observed to avoid the risk of injury 

or death to the user.

 Caution:

Describes precautions that should be observed to prevent damage to the unit.

Symbols used in the illustrations

: Indicates an action that must be avoided.
: Indicates that important instructions must be followed.
: Indicates a part which must be grounded.
: Indicates that caution should be taken with rotating parts. (This symbol 

is displayed on the main unit label.) <Color: yellow>

: Beware of electric shock. (This symbol is displayed on the main unit la-

bel.) <Color: yellow>

 Warning:

Carefully read the labels affixed to the main unit.

1.1. Installation

u

  After you have read this manual, keep it and the Installation Manual in 

a safe place for easy reference whenever a question arises. If the unit 

is going to be operated by another person, make sure that this manual 

is given to him or her.

 Warning:

• 

The unit should not be installed by the user. Ask the dealer or an au-

thorized company to install the unit. If the unit is installed improperly, 

water leakage, electric shock or fire may result.

• 

Use only accessories authorized by Mitsubishi Electric and ask your deal-

er or an authorized company to install them. If accessories are installed 

improperly, water leakage, electric shock or fire may result.

• 

The Installation Manual details the suggested installation method. Any 

structural alteration necessary for installation must comply with local 

building code requirements.

• 

Never repair the unit or transfer it to another site by yourself. If repair is 

performed improperly, water leakage, electric shock or fire may result. 

If you need to have the unit repaired or moved, consult your dealer.

• 

Keep the electric parts away from water (washing water) etc.

•  It might result in electric shock, catching fire or smoke.

Note1: When washing the Heat Exchanger and Drain Pan, ensure the 

Control Box, Motor and LEV remain dry, using a water proof 

covering.

Note2: Never drain the washing water for the Drain Pan and the Heat 

Exchanger using the Drain Pump. Drain separately.

•  The appliance is not intended for use by young children or infirm per

-

sons without supervision.

• 

Young children should be supervised to ensure that they do not play 

with the appliance.

• 

Do not use a leak detection additive.

• 

Do not use refrigerant other than the type indicated in the manuals pro-

vided with the unit and on the nameplate.

-  Doing so may cause the unit or pipes to burst, or result in explosion or fire 

during use, during repair, or at the time of disposal of the unit.

-  It may also be in violation of applicable laws.

-  MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for mal-

functions or accidents resulting from the use of the wrong type of refrigerant.

1. Safety precautions

1)  Outdoor unit

 Warning:

• 

The outdoor unit must be installed on a stable, level surface, in a place 

where there is no accumulation of snow, leaves or rubbish.

• 

Do not stand on, or place any items on the unit. You may fall down or 

the item may fall, causing injury.

 Caution:

The outdoor unit should be installed in a location where air and noise emit-

ted by the unit will not disturb the neighbours.

2)  Indoor unit

 Warning:

The indoor unit should be securely installed. If the unit is loosely mounted, 

it may fall, causing injury.

3)  Remote controller

 Warning:

The remote controller should be installed in such a way that children can-

not play with it.

4)  Drain hose

 Caution:

Make sure that the drain hose is installed so that drainage can go ahead 

smoothly. Incorrect installation may result in water leakage, causing dam-

age to furniture.

5)  Power line, fuse or circuit breaker

 Warning:

• 

Make sure that the unit is powered by a dedicated supply. Other appli-

ances connected to the same supply could cause an overload.

• 

Make sure that there is a main power switch.

• 

Be sure to adhere to the unit’s voltage and fuse or circuit breaker rat-

ings. Never use a piece of wire or a fuse with a higher rating than the 

one specified.

6) Grounding

 Caution:

• 

The unit must be properly grounded. Never connect the grounding wire 

to a gas pipe, water pipe, lightning conductor or tele phone grounding 

wire. If the unit is not grounded properly, electric shock may result.

• 

Check frequently that the ground wire from the outdoor unit is properly 

connected to both the unit’s ground terminal and the grounding elec-

trode.

1.2.  During operation

 Caution:

• 

Do not use any sharp object to push the buttons, as this may damage 

the remote controller.

• 

Do not twist or tug on the remote controller cord as this may damage 

the remote controller and cause malfunction.

• 

Never remove the upper case of the remote controller. It is dangerous 

to remove the upper case of the remote controller and touch the printed 

circuit boards inside. Doing so can result in fire and failure.

• 

Never wipe the remote controller with benzene, thinner, chemical rags, 

etc. Doing so can result in discoloration and failure. To remove heavy 

stains, soak a cloth in neutral detergent mixed with water, wring it out 

thoroughly, wipe the stains off, and wipe again with a dry cloth.

• 

Never block or cover the indoor or outdoor unit’s intakes or outlets. Tall 

items of furniture underneath the indoor unit, or bulky items such as 

large boxes placed close to the outdoor unit will reduce the unit’s ef-

ficiency.

Note: 

If you use other remote controllers, refer to either Installation Manual or Initial Setting Manual that comes with the controller to be used.

1.  Safety precautions ........................................................................................4

 

1.1. Installation ...................................................................................4

 

1.2.  During operation .........................................................................4

 1.3. 

Disposing of the unit .................................................................... 5

2.  Names and functions of various parts ..........................................................5

3.  How to operate .............................................................................................5

 

3.1. ON/OFF ......................................................................................5

 3.2. 

Selecting operation ...........................................................................5

 

3.3.  Room temperature adjustment ...................................................6

 

3.4.  Fan speed adjustment ................................................................6

 

3.5.  Adjustment of up/down airflow direction

 .....................................6

 

3.6. Others .........................................................................................7

4.  The smart way to use ...................................................................................7

5.  Caring for the machine .................................................................................7

6. Troubleshooting ............................................................................................8

7.  Installation, transferring works, and checking ..............................................9

8.  Specifications

 ...............................................................................................9

Summary of Contents for City Multi PEFY-P-NMHSU-E

Page 1: ...operating the air conditioner unit MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur Air Conditioners INDOOR UNIT PEFY P NMHU E 2 PEFY P NMHU E F PLFY P NLMU E PFFY P NEMU E PFFY P NRMU E PEFY P NMHSU E ...

Page 2: ...e Filter b Touche ON OFF Touche c Position du capteur de température de la pièce intégré d Touche de réglage de l heure Ne jamais laisser la commande à distance en plein soleil sinon les données de température ambiante risquent d être erronées Ne jamais placer d obstacle devant la partie inférieure droite de la com mande à distance sinon la lecture des températures ne sera pas correcte ON OFF ERRO...

Page 3: ...3 Fig A PLFY P NLMU E A PEFY P NMHU E 2 PEFY P NMHU E F A A PEFY P NMHSU E PFFY P NEMU E NRMU E A A A Filter Air Flow Filtre Flux d air ...

Page 4: ...y precautions 1 Outdoor unit Warning The outdoor unit must be installed on a stable level surface in a place where there is no accumulation of snow leaves or rubbish Do not stand on or place any items on the unit You may fall down or the item may fall causing injury Caution The outdoor unit should be installed in a location where air and noise emit ted by the unit will not disturb the neighbours 2...

Page 5: ...nit Warning When you need to dispose of the unit consult your dealer If pipes are re moved incorrectly refrigerant fluorocarbon gas may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environment 2 Names and functions of various parts Attachment and detachment of filter Fig A P 3 Caution In removing the filter precautions must...

Page 6: ...etc The fan speed comes to low or high Except PEFY P NMHU E F 3 3 Room temperature adjustment To change room temperature Press the 1 Set Temperature Button and set the room temperature of your choice Pressing or once changes the setting by 1 C 1 F If the pressing is continued the setting continues to change by 1 C 2 F Indoor temperature can be set within the following range Cooling dry 19 C 67 F 3...

Page 7: ... you start cleaning stop operation and turn OFF the power sup ply Remember that the fan is rotating inside at high speed posing a serious risk of injury Indoor units are equipped with filters to remove the dust of sucked in air Clean the filters using the methods shown in the following sketch es The standard filter should normally be cleaned once a week and the long life filter at the beginning of...

Page 8: ...ped Wait for 3 minutes The sound of the ex haust and the rotation of the motor can be heard intermittently after stop of running All lights are out ex cept the powered dis play of When other indoor units are engaged in cooling operation drained water is brought in If the drain water is collected the drain up mechanism initiates a draining operation It soon stops If the noise occurs more than 2 3 t...

Page 9: ...ferring the instal lation Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can result in electric shock fire etc Regarding noise In installing work choose a place that can fully bear the weight of the air con ditioner and where noise and vibration can be reduced Choose a place where cool or warm air and noise from the outdoor air outlet of the...

Page 10: ...ating kW 11 7 15 8 17 6 23 4 31 7 BTU h 40000 54000 60000 80000 108000 Dimension Height mm 380 470 in 15 18 9 16 Width mm 1195 1250 in 47 1 4 49 1 4 Depth mm 900 1120 in 35 7 16 44 1 8 Net weight kg 69 71 100 lb 153 157 221 FAN Airflow rate Low High m3 min 26 5 38 0 26 5 38 0 28 0 40 0 58 0 72 0 cfm 936 1342 936 1342 989 1412 2048 2541 External static pres sure 3 Pa 208V 100 250 100 250 100 250 70...

Page 11: ...r the factory setting is below PEFY P NMHU E F series PEFY P30NMHU E F PEFY P54NMHU E F PEFY P72NMHU E F PEFY P96NMHU E F 208V 230V 208V 230V 208V 230V 208V 230V 85 130 85 130 180 260 180 260 PEFY P NMHSU E Model Item PEFY P72NMHSU E PEFY P96NMHSU E Power source 208 230V 60Hz Capacity 1 Cooling kW 21 1 28 1 BTU h 72000 96000 Heating kW 23 4 31 7 BTU h 80000 108000 Dimension Height mm 470 in 18 9 1...

Page 12: ...MU E PFFY P12NRMU E PFFY P15NRMU E PFFY P18NRMU E PFFY P24NRMU E Power source 208 230V 60Hz Capacity 1 Cooling kW 1 8 2 3 3 5 4 4 5 3 7 0 BTU h 6000 8000 12000 15000 18000 24000 Heating kW 2 0 2 6 4 0 5 0 5 9 7 9 BTU h 6700 9000 13500 17000 20000 27000 Dimension Height mm 630 in 25 3 16 Width mm 886 1006 1246 in 34 15 16 39 5 8 49 1 16 Depth mm 220 in 8 11 16 Net weight kg 19 19 20 21 25 27 lb 41 ...

Page 13: ...e le moteur et le LEV restent secs en utilisant une couverture étanche Note 2 N évacuez jamais l eau de lavage pour la cuvette d écoulement et l échangeur thermique avec la pompe de drainage Evacuez la séparément Ne pas permettre l usage de cet appareil à des enfants en bas âge ou à des handicapés sans supervision Toujours prendre toutes les précautions nécessaires pour éviter que des enfants en b...

Page 14: ...e certaine période Si le climatiseur ne doit pas être utilisé pendant une certaine période à cause d un changement de climat etc le faire fonctionner pendant 4 5 heures avec la soufflerie d air jusqu à ce que l intérieur soit complète ment sec Sinon de la moisissure non hygiénique et insalubre risque de se développer à des endroits divers Lorsqu il ne doit pas être utilisé pendant un certain temps...

Page 15: ...é par le climatiseur sinon sa combustion sera irrégulière Le micro ordinateur fonctionne dans les cas suivants L air ne souffle pas lorsque le chauffage démarre Pour éviter le souffle d air froid le ventilateur interne est progressivement allumé par étapes entre un très léger souffle un léger souffle la soufflerie programmée en fonction de l augmentation de la température de l air propulsé Il faut...

Page 16: ... durée doivent l être au début de chaque saison d utilisation La durée de vie du filtre dépend du lieu d installation de l appareil et de son fonctionnement Comment nettoyer les filtres Brosser doucement la poussière ou nettoyer le filtre avec l aspirateur En cas de taches persistantes laver le filtre dans de l eau tiède avec un détergent non abrasif ou dans de l eau pure puis rincer convenablemen...

Page 17: ...e la rotation du moteur est toujours audible par intermit tence après l arrêt du climatiseur Tous les témoins sont éteints sauf le témoin de mise sous tension Lorsque d autres appareils intérieurs sont program més pour le refroidissement l eau d écoulement est amenée à l intérieur Lorsque l eau d écoulement est rassemblée le mécanisme d écoulement entame l opération de drainage Le bruit s arrête r...

Page 18: ...ur une estimation du coût des travaux requis pour le démé nagement de l installation Précaution Lors du déménagement et de la réinstallation du climatiseur veuillez prendre contact avec votre revendeur car une installation défectueuse peut être la cause d électrocution d incendie etc Faire également attention au bruit Lors des travaux d installation choisir un endroit capable de supporter entiè re...

Page 19: ...000 54000 60000 80000 108000 Dimensions Hauteur mm 380 470 in 15 18 9 16 Largeur mm 1195 1250 in 47 1 4 49 1 4 Profondeur mm 900 1120 in 35 7 16 44 1 8 Poids net kg 69 71 100 lb 153 157 221 VENTILA TEUR Débit de l air Faible Haut m3 min 26 5 38 0 26 5 38 0 28 0 40 0 58 0 72 0 cfm 936 1342 936 1342 989 1412 2048 2541 Pression statique externe 3 Pa 208V 100 250 100 250 100 250 70 160 70 160 230V 150...

Page 20: ...ages d usine Séries PEFY P NMHU E F PEFY P30NMHU E F PEFY P54NMHU E F PEFY P72NMHU E F PEFY P96NMHU E F 208V 230V 208V 230V 208V 230V 208V 230V 85 130 85 130 180 260 180 260 PEFY P NMHSU E Modèle Élément PEFY P72NMHSU E PEFY P96NMHSU E Source d alimentation 208 230V 60Hz Capacité 1 Refroidissement kW 21 1 28 1 BTU h 72000 96000 Chauffage kW 23 4 31 7 BTU h 80000 108000 Dimensions Hauteur mm 470 in...

Page 21: ... P24NRMU E Source d alimentation 208 230V 60Hz Capacité 1 Refroidissement kW 1 8 2 3 3 5 4 4 5 3 7 0 BTU h 6000 8000 12000 15000 18000 24000 Chauffage kW 2 0 2 6 4 0 5 0 5 9 7 9 BTU h 6700 9000 13500 17000 20000 27000 Dimensions Hauteur mm 630 in 25 3 16 Largeur mm 886 1006 1246 in 34 15 16 39 5 8 49 1 16 Profondeur mm 220 in 8 11 16 Poids net kg 19 19 20 21 25 27 lb 41 41 45 47 56 60 VENTILA TEUR...

Page 22: ......

Page 23: ......

Page 24: ...ne number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT06893X01 This product is designed and intended for use in the residential commercial and light industrial environment ...

Reviews: