Press the 

3

 [Mode (BACK)] Button and bring up the “

   DRY

” display.

• 

The indoor fan turns to the low-speed operation, disabling the change of fan 

speed.

• 

Dry operation cannot be carried out at room temperature of less than 18 °C 

[65 °F].

For fan

Press the 

3

 [Mode (BACK)] Button and bring up the “

   FAN

” display.

• 

The fan operation functions to circulate the air in the room.

• 

The temperature of the room cannot be set by fan operation.

 Caution:

Never expose your body directly to cool air for a long time. Excessive ex-

posure to cool air is bad for your health, and should therefore be avoided.

Dry operation

The dry is a microcomputer-controlled dehumidifying operation which controls 

excessive air-cooling according to the room temperature of your choice. (Not us-

able for heating.)
1.  Until reaching room temperature of your choice

 

The compressor and indoor fan function is linked motion according to the 

change of the room temperature and automatically repeat ON/OFF.

2.  When reaching room temperature of your choice

 

Both the compressor and indoor fan stop.

 

When stop continues for 10 minutes, the compressor and indoor fan are 

operated for 3 minutes to keep the humidity low.

For heating

Press the 

3

 [Mode (BACK)] Button and bring up the “

   HEAT

” display.

Regarding displays during heating operation “DEFROST”

Displayed only during the defrosting operation.

“STAND BY”

Displayed from the start of heating operation until the moment warm air blows 

out.

 Caution:

• 

When the air-conditioner is used together with burners, thoroughly 

ventilate the area. Insufficient ventilation can result in accidents due to 

oxygen deficiency.

•  Never place a burner at a place where it is exposed to the airflow from 

the air-conditioner.

Doing so can result in imperfect combustion of the burner.

• 

The microcomputer functions in the following cases: *

• 

Air does not blow out when heating starts. *

-  To prevent any cool air from escaping, the indoor fan is gradually switched 

in sequence from faint airflow/weak airflow/set airflow according to the 

temperature rise of the blown out air. Wait a moment until the airflow 

comes out naturally.

• 

The fan is not moving at the set speed. *

-  In some models, the system switches over to faint airflow when the tem

-

per-ature of the room reaches the set temperature. In other cases, it stops 

to prevent any cool air from escaping during the defrosting operation.

•  Air flows out even if operation is stopped. *

-  Approximately 1 minute after the stop of operation, the indoor fan some-

times rotates to eliminate extra heat generated by the electric heater, etc.

  The fan speed comes to low or high.

*  Except PEFY-P-NMHU-E-F.

3.3.  Room temperature adjustment

To change room temperature

Press the 

1

 [Set Temperature] Button and set the room temperature of 

your choice.

Pressing 

 or 

 once changes the setting by 1 °C / 1 °F.

If the pressing is continued, the setting continues to change by 1 °C [2 °F].

• 

Indoor temperature can be set within the following range.

  Cooling/dry 

:19 °C [67 °F] - 30 °C [87 °F]

  Heating 

:17 °C [63 °F] - 28 °C [83 °F]

• 

Temperature cannot be set for the fan mode.

• 

The range of room temperature display is 8 °C [46 °F] - 39 °C [102 °F]. 

Outside this range, the display flashes either 8 °C [46 °F] - 39 °C [102 °F] to 

inform you if the room temperature is lower or higher than the displayed tem-

perature.

3.4.  Fan speed adjustment

* Except PEFY-P-NMHU-E-F.

To change fan speed

Every time you press the 

6

 [Fan Speed] button once, it switches from the low-

speed to high-speed settings successively.

In the electronics dry operation, the indoor fan automatically turns to low-speed 

operation. Switching of fan speed is impossible. (Only the display on the remote 

controller changes.)
*  Every time the fan speed adjustment button is pressed once, the fan speed 

is changed.

 

„

PEFY-P72·96NMHU-E

Fan speed : 1 stage

Display: 

 (High)

 

„

PEFY-P72·96NMHSU-E

Fan speed : 3 stages

Display: 

 (Low)

 

 (Mid)

 

 (High)

 

 (AUTO*)

*  This setting can be adjusted only with MA remote controller.

 

„

PEFY-P15~54NMHU-E2, PFFY-P-NEMU-E, PFFY-P-NRMU-E series

Fan speed : 2 stages

Display: 

 (Low)

 

 (High)

 

 (Low) 

(repeat)

 

„

PLFY-P06~18NLMU-E, PEFY-P-NMLU-E series

Fan speed : 3 stages

Display: 

 (Low)

 

 (Mid)

 

 (High)

 

 (Low) 

(repeat)

3.5.  Adjustment of up/down airflow direc

-

tion

To change the up/down airflow direction

Every time the 

7

 [Vane Control] button is pressed, the direction of the air-

flow changes.

[PLFY-P-NLMU-E]

Display

 

1

 Swing 

2

 0° 

3

 40° 

4

 60° 

5

 80°

Mode

Fan speed

1

2

3

4

5

Heating/Fan High/Mid/Low

Cooling

High

Mid/Low

1

2

3

4

5

Dry

Fixed

Initial setting

Cooling

Dry

Fan

Heating

*1  •  It automatically returns to the “

2

 0°” when one hour passes.

  •  The “1 Hr.” is displayed on the remote controller (It is disappeared when 

one hour passes.)

• 

This function is not available according to the models.

• 

There may be a discrepancy between the vane position on the display and 

the actual vane position in the following conditions:

1.  When “DEFROST” or “STAND BY” is displayed on the controller

2.  At the beginning of heating operation

3.  Thermo-OFF in the heating mode

PFFY-P-NEMU-E

While pulling the blowout grill out toward you, raise the rear, remove it, change 

the direction, and set it in place.

 Caution:

Avoid putting your hand into the air outlet of the indoor unit any more than 

necessary. If you get your hands caught in the metal parts when adjusting 

the airflow-direction-adjustment board and blowout grill, or nip them in the 

autovane, there is a risk of injury and failure.

Summary of Contents for City Multi PEFY-P-NMHSU-E

Page 1: ...operating the air conditioner unit MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur Air Conditioners INDOOR UNIT PEFY P NMHU E 2 PEFY P NMHU E F PLFY P NLMU E PFFY P NEMU E PFFY P NRMU E PEFY P NMHSU E ...

Page 2: ...e Filter b Touche ON OFF Touche c Position du capteur de température de la pièce intégré d Touche de réglage de l heure Ne jamais laisser la commande à distance en plein soleil sinon les données de température ambiante risquent d être erronées Ne jamais placer d obstacle devant la partie inférieure droite de la com mande à distance sinon la lecture des températures ne sera pas correcte ON OFF ERRO...

Page 3: ...3 Fig A PLFY P NLMU E A PEFY P NMHU E 2 PEFY P NMHU E F A A PEFY P NMHSU E PFFY P NEMU E NRMU E A A A Filter Air Flow Filtre Flux d air ...

Page 4: ...y precautions 1 Outdoor unit Warning The outdoor unit must be installed on a stable level surface in a place where there is no accumulation of snow leaves or rubbish Do not stand on or place any items on the unit You may fall down or the item may fall causing injury Caution The outdoor unit should be installed in a location where air and noise emit ted by the unit will not disturb the neighbours 2...

Page 5: ...nit Warning When you need to dispose of the unit consult your dealer If pipes are re moved incorrectly refrigerant fluorocarbon gas may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environment 2 Names and functions of various parts Attachment and detachment of filter Fig A P 3 Caution In removing the filter precautions must...

Page 6: ...etc The fan speed comes to low or high Except PEFY P NMHU E F 3 3 Room temperature adjustment To change room temperature Press the 1 Set Temperature Button and set the room temperature of your choice Pressing or once changes the setting by 1 C 1 F If the pressing is continued the setting continues to change by 1 C 2 F Indoor temperature can be set within the following range Cooling dry 19 C 67 F 3...

Page 7: ... you start cleaning stop operation and turn OFF the power sup ply Remember that the fan is rotating inside at high speed posing a serious risk of injury Indoor units are equipped with filters to remove the dust of sucked in air Clean the filters using the methods shown in the following sketch es The standard filter should normally be cleaned once a week and the long life filter at the beginning of...

Page 8: ...ped Wait for 3 minutes The sound of the ex haust and the rotation of the motor can be heard intermittently after stop of running All lights are out ex cept the powered dis play of When other indoor units are engaged in cooling operation drained water is brought in If the drain water is collected the drain up mechanism initiates a draining operation It soon stops If the noise occurs more than 2 3 t...

Page 9: ...ferring the instal lation Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can result in electric shock fire etc Regarding noise In installing work choose a place that can fully bear the weight of the air con ditioner and where noise and vibration can be reduced Choose a place where cool or warm air and noise from the outdoor air outlet of the...

Page 10: ...ating kW 11 7 15 8 17 6 23 4 31 7 BTU h 40000 54000 60000 80000 108000 Dimension Height mm 380 470 in 15 18 9 16 Width mm 1195 1250 in 47 1 4 49 1 4 Depth mm 900 1120 in 35 7 16 44 1 8 Net weight kg 69 71 100 lb 153 157 221 FAN Airflow rate Low High m3 min 26 5 38 0 26 5 38 0 28 0 40 0 58 0 72 0 cfm 936 1342 936 1342 989 1412 2048 2541 External static pres sure 3 Pa 208V 100 250 100 250 100 250 70...

Page 11: ...r the factory setting is below PEFY P NMHU E F series PEFY P30NMHU E F PEFY P54NMHU E F PEFY P72NMHU E F PEFY P96NMHU E F 208V 230V 208V 230V 208V 230V 208V 230V 85 130 85 130 180 260 180 260 PEFY P NMHSU E Model Item PEFY P72NMHSU E PEFY P96NMHSU E Power source 208 230V 60Hz Capacity 1 Cooling kW 21 1 28 1 BTU h 72000 96000 Heating kW 23 4 31 7 BTU h 80000 108000 Dimension Height mm 470 in 18 9 1...

Page 12: ...MU E PFFY P12NRMU E PFFY P15NRMU E PFFY P18NRMU E PFFY P24NRMU E Power source 208 230V 60Hz Capacity 1 Cooling kW 1 8 2 3 3 5 4 4 5 3 7 0 BTU h 6000 8000 12000 15000 18000 24000 Heating kW 2 0 2 6 4 0 5 0 5 9 7 9 BTU h 6700 9000 13500 17000 20000 27000 Dimension Height mm 630 in 25 3 16 Width mm 886 1006 1246 in 34 15 16 39 5 8 49 1 16 Depth mm 220 in 8 11 16 Net weight kg 19 19 20 21 25 27 lb 41 ...

Page 13: ...e le moteur et le LEV restent secs en utilisant une couverture étanche Note 2 N évacuez jamais l eau de lavage pour la cuvette d écoulement et l échangeur thermique avec la pompe de drainage Evacuez la séparément Ne pas permettre l usage de cet appareil à des enfants en bas âge ou à des handicapés sans supervision Toujours prendre toutes les précautions nécessaires pour éviter que des enfants en b...

Page 14: ...e certaine période Si le climatiseur ne doit pas être utilisé pendant une certaine période à cause d un changement de climat etc le faire fonctionner pendant 4 5 heures avec la soufflerie d air jusqu à ce que l intérieur soit complète ment sec Sinon de la moisissure non hygiénique et insalubre risque de se développer à des endroits divers Lorsqu il ne doit pas être utilisé pendant un certain temps...

Page 15: ...é par le climatiseur sinon sa combustion sera irrégulière Le micro ordinateur fonctionne dans les cas suivants L air ne souffle pas lorsque le chauffage démarre Pour éviter le souffle d air froid le ventilateur interne est progressivement allumé par étapes entre un très léger souffle un léger souffle la soufflerie programmée en fonction de l augmentation de la température de l air propulsé Il faut...

Page 16: ... durée doivent l être au début de chaque saison d utilisation La durée de vie du filtre dépend du lieu d installation de l appareil et de son fonctionnement Comment nettoyer les filtres Brosser doucement la poussière ou nettoyer le filtre avec l aspirateur En cas de taches persistantes laver le filtre dans de l eau tiède avec un détergent non abrasif ou dans de l eau pure puis rincer convenablemen...

Page 17: ...e la rotation du moteur est toujours audible par intermit tence après l arrêt du climatiseur Tous les témoins sont éteints sauf le témoin de mise sous tension Lorsque d autres appareils intérieurs sont program més pour le refroidissement l eau d écoulement est amenée à l intérieur Lorsque l eau d écoulement est rassemblée le mécanisme d écoulement entame l opération de drainage Le bruit s arrête r...

Page 18: ...ur une estimation du coût des travaux requis pour le démé nagement de l installation Précaution Lors du déménagement et de la réinstallation du climatiseur veuillez prendre contact avec votre revendeur car une installation défectueuse peut être la cause d électrocution d incendie etc Faire également attention au bruit Lors des travaux d installation choisir un endroit capable de supporter entiè re...

Page 19: ...000 54000 60000 80000 108000 Dimensions Hauteur mm 380 470 in 15 18 9 16 Largeur mm 1195 1250 in 47 1 4 49 1 4 Profondeur mm 900 1120 in 35 7 16 44 1 8 Poids net kg 69 71 100 lb 153 157 221 VENTILA TEUR Débit de l air Faible Haut m3 min 26 5 38 0 26 5 38 0 28 0 40 0 58 0 72 0 cfm 936 1342 936 1342 989 1412 2048 2541 Pression statique externe 3 Pa 208V 100 250 100 250 100 250 70 160 70 160 230V 150...

Page 20: ...ages d usine Séries PEFY P NMHU E F PEFY P30NMHU E F PEFY P54NMHU E F PEFY P72NMHU E F PEFY P96NMHU E F 208V 230V 208V 230V 208V 230V 208V 230V 85 130 85 130 180 260 180 260 PEFY P NMHSU E Modèle Élément PEFY P72NMHSU E PEFY P96NMHSU E Source d alimentation 208 230V 60Hz Capacité 1 Refroidissement kW 21 1 28 1 BTU h 72000 96000 Chauffage kW 23 4 31 7 BTU h 80000 108000 Dimensions Hauteur mm 470 in...

Page 21: ... P24NRMU E Source d alimentation 208 230V 60Hz Capacité 1 Refroidissement kW 1 8 2 3 3 5 4 4 5 3 7 0 BTU h 6000 8000 12000 15000 18000 24000 Chauffage kW 2 0 2 6 4 0 5 0 5 9 7 9 BTU h 6700 9000 13500 17000 20000 27000 Dimensions Hauteur mm 630 in 25 3 16 Largeur mm 886 1006 1246 in 34 15 16 39 5 8 49 1 16 Profondeur mm 220 in 8 11 16 Poids net kg 19 19 20 21 25 27 lb 41 41 45 47 56 60 VENTILA TEUR...

Page 22: ......

Page 23: ......

Page 24: ...ne number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT06893X01 This product is designed and intended for use in the residential commercial and light industrial environment ...

Reviews: