Regarding place for installation

Consult with your dealer for details on installation and transferring the installa-

tion.

 Caution:

Never install the air conditioner where there is a risk of leakage of flamma

-

ble gas.

If gas leaks and accumulates around the unit, fire can result.

Never install the air conditioner at the following place:

• 

where there is a lot of machine oil

• 

near the ocean and beach areas where there is salt air.

• 

where humidity is high

• 

where there are hot springs nearby

• 

where there is sulphurous gas

• 

where there is a high-frequency processing machinery (a high-frequency 

welder, etc.)

• 

where acid solution is frequently used

• 

where special sprays are frequently used

• 

Install the indoor unit horizontally. Otherwise, water leakage can result.

•  Take sufficient measures against noise when installing the air conditioners at 

hospitals or communication-related businesses.

If the air conditioner is used in any of the above-mentioned environments, fre-

quent operational failure can be expected. It is advisable to avoid these types of 

installation sites.

For further details, consult with your dealer.

Regarding electrical work

 Caution:

•  The  electrical  work  must  be  undertaken  by  a  person  who  is  qualified 

as an electrical engineer according to the [technical standard respect-

ing  electrical  installation],  [internal  wiring  rules],  and  the  installation 

instruction manual with the absolute use of exclusive circuits. The use 

of other products with the power source can result in burnt-out beakers 

and fuses.

•  Never connect the grounding wire to a gas pipe, water pipe, arrester, or 

telephone grounding wire. For details, consult with your dealer.

•  In some types of installation sites, the installation of an earth leakage 

breaker is mandatory. For details, consult with your dealer.

Regarding transfer of installation

• 

When removing and reinstalling the air conditioner when you enlarge your 

home, remodel, or move, consult with your dealer in advance to ascertain the 

cost of the professional engineering work required for transferring the instal-

lation.

 Caution:

When moving or reinstalling the air conditioner, consult with your dealer. 

Defective installation can result in electric shock, fire, etc.

Regarding noise

• 

In installing work, choose a place that can fully bear the weight of the air con-

ditioner, and where noise and vibration can be reduced.

• 

Choose a place where cool or warm air and noise from the outdoor air outlet 

of the air conditioner does not inconvenience the neighbors.

• 

If any alien object is placed near the outdoor air outlet of the air conditioner, 

decreased performance and increased noise can result. Avoid placing any 

obstacles adjacent to the air outlet.

• 

If the air conditioner produces any abnormal sound, consult with your dealer.

Maintenance and inspection

• 

If the air conditioner is used throughout several seasons, the insides can get 

dirty, reducing the performance.

Depending upon the conditions of usage, foul odors can be generated and 

drainage can deteriorate due to dust and dirt, etc.

7. Installation, transferring works, and checking

8. Specifications

PLFY-P-NLMU-E

Model

Item

PLFY-P06NLMU-E PLFY-P08NLMU-E PLFY-P12NLMU-E PLFY-P15NLMU-E PLFY-P18NLMU-E

Power source

208/230V, 60Hz

Capacity 

*1

Cooling

kW

1.8

2.3

3.5

4.4

5.3

BTU/h

6000

8000

12000

15000

18000

Heating

kW

2.0

2.6

4.0

5.0

5.9

BTU/h

6700

9000

13500

17000

20000

Dimension 

*3

Height

mm

290 (20)

in

11-7/16 (13/16)

Width

mm

776 (1080)

946 (1250)

in

30-9/16 (42-9/16)

37-1/4 (49-1/4)

Depth

mm

634 (710)

in

25 (28)

Net weight

kg

23 (6.5)

24 (6.5)

27 (7.5)

lb

51 (15)

53 (15)

60 (17)

FAN

Airflow rate

(Low-Middle-High)

m

3

/min

6.5-8.0-9.5

6.5-8.0-9.5

6.5-8.0-9.5

7.0-8.5-10.5

9.0-11.0-12.5

cfm

230-282-335

230-282-335

230-282-335

247-300-371

318-388-441

External static pres-

sure

Pa

208V

-

-

-

-

-

230V

-

-

-

-

-

Noise level

(Low-Middle-High) *2

dB(A)

208V

27-30-33

27-30-33

27-30-33

29-33-36

31-34-37

230V

28-31-34

28-31-34

28-31-34

30-34-37

32-35-38

Filter

Standard filter

Notes: *1  Cooling/Heating capacity indicates the maximum value at operation under the following condition.

 

  Cooling: Indoor: 26.7 °C [80 °F] DB/19.4 °C [67 °F] WB 

Outdoor: 35 °C [95 °F] DB

 

  Heating: Indoor: 21.1 °C [70 °F] DB 

Outdoor: 8.3 °C [47 °F] DB/6.1 °C [43 °F] WB

 

*2  The operating noise is the data that was obtained in an anechoic room.

 

*3  The figure in ( ) indicates Panel's.

Summary of Contents for City Multi PEFY-P-NMHSU-E

Page 1: ...operating the air conditioner unit MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur Air Conditioners INDOOR UNIT PEFY P NMHU E 2 PEFY P NMHU E F PLFY P NLMU E PFFY P NEMU E PFFY P NRMU E PEFY P NMHSU E ...

Page 2: ...e Filter b Touche ON OFF Touche c Position du capteur de température de la pièce intégré d Touche de réglage de l heure Ne jamais laisser la commande à distance en plein soleil sinon les données de température ambiante risquent d être erronées Ne jamais placer d obstacle devant la partie inférieure droite de la com mande à distance sinon la lecture des températures ne sera pas correcte ON OFF ERRO...

Page 3: ...3 Fig A PLFY P NLMU E A PEFY P NMHU E 2 PEFY P NMHU E F A A PEFY P NMHSU E PFFY P NEMU E NRMU E A A A Filter Air Flow Filtre Flux d air ...

Page 4: ...y precautions 1 Outdoor unit Warning The outdoor unit must be installed on a stable level surface in a place where there is no accumulation of snow leaves or rubbish Do not stand on or place any items on the unit You may fall down or the item may fall causing injury Caution The outdoor unit should be installed in a location where air and noise emit ted by the unit will not disturb the neighbours 2...

Page 5: ...nit Warning When you need to dispose of the unit consult your dealer If pipes are re moved incorrectly refrigerant fluorocarbon gas may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environment 2 Names and functions of various parts Attachment and detachment of filter Fig A P 3 Caution In removing the filter precautions must...

Page 6: ...etc The fan speed comes to low or high Except PEFY P NMHU E F 3 3 Room temperature adjustment To change room temperature Press the 1 Set Temperature Button and set the room temperature of your choice Pressing or once changes the setting by 1 C 1 F If the pressing is continued the setting continues to change by 1 C 2 F Indoor temperature can be set within the following range Cooling dry 19 C 67 F 3...

Page 7: ... you start cleaning stop operation and turn OFF the power sup ply Remember that the fan is rotating inside at high speed posing a serious risk of injury Indoor units are equipped with filters to remove the dust of sucked in air Clean the filters using the methods shown in the following sketch es The standard filter should normally be cleaned once a week and the long life filter at the beginning of...

Page 8: ...ped Wait for 3 minutes The sound of the ex haust and the rotation of the motor can be heard intermittently after stop of running All lights are out ex cept the powered dis play of When other indoor units are engaged in cooling operation drained water is brought in If the drain water is collected the drain up mechanism initiates a draining operation It soon stops If the noise occurs more than 2 3 t...

Page 9: ...ferring the instal lation Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can result in electric shock fire etc Regarding noise In installing work choose a place that can fully bear the weight of the air con ditioner and where noise and vibration can be reduced Choose a place where cool or warm air and noise from the outdoor air outlet of the...

Page 10: ...ating kW 11 7 15 8 17 6 23 4 31 7 BTU h 40000 54000 60000 80000 108000 Dimension Height mm 380 470 in 15 18 9 16 Width mm 1195 1250 in 47 1 4 49 1 4 Depth mm 900 1120 in 35 7 16 44 1 8 Net weight kg 69 71 100 lb 153 157 221 FAN Airflow rate Low High m3 min 26 5 38 0 26 5 38 0 28 0 40 0 58 0 72 0 cfm 936 1342 936 1342 989 1412 2048 2541 External static pres sure 3 Pa 208V 100 250 100 250 100 250 70...

Page 11: ...r the factory setting is below PEFY P NMHU E F series PEFY P30NMHU E F PEFY P54NMHU E F PEFY P72NMHU E F PEFY P96NMHU E F 208V 230V 208V 230V 208V 230V 208V 230V 85 130 85 130 180 260 180 260 PEFY P NMHSU E Model Item PEFY P72NMHSU E PEFY P96NMHSU E Power source 208 230V 60Hz Capacity 1 Cooling kW 21 1 28 1 BTU h 72000 96000 Heating kW 23 4 31 7 BTU h 80000 108000 Dimension Height mm 470 in 18 9 1...

Page 12: ...MU E PFFY P12NRMU E PFFY P15NRMU E PFFY P18NRMU E PFFY P24NRMU E Power source 208 230V 60Hz Capacity 1 Cooling kW 1 8 2 3 3 5 4 4 5 3 7 0 BTU h 6000 8000 12000 15000 18000 24000 Heating kW 2 0 2 6 4 0 5 0 5 9 7 9 BTU h 6700 9000 13500 17000 20000 27000 Dimension Height mm 630 in 25 3 16 Width mm 886 1006 1246 in 34 15 16 39 5 8 49 1 16 Depth mm 220 in 8 11 16 Net weight kg 19 19 20 21 25 27 lb 41 ...

Page 13: ...e le moteur et le LEV restent secs en utilisant une couverture étanche Note 2 N évacuez jamais l eau de lavage pour la cuvette d écoulement et l échangeur thermique avec la pompe de drainage Evacuez la séparément Ne pas permettre l usage de cet appareil à des enfants en bas âge ou à des handicapés sans supervision Toujours prendre toutes les précautions nécessaires pour éviter que des enfants en b...

Page 14: ...e certaine période Si le climatiseur ne doit pas être utilisé pendant une certaine période à cause d un changement de climat etc le faire fonctionner pendant 4 5 heures avec la soufflerie d air jusqu à ce que l intérieur soit complète ment sec Sinon de la moisissure non hygiénique et insalubre risque de se développer à des endroits divers Lorsqu il ne doit pas être utilisé pendant un certain temps...

Page 15: ...é par le climatiseur sinon sa combustion sera irrégulière Le micro ordinateur fonctionne dans les cas suivants L air ne souffle pas lorsque le chauffage démarre Pour éviter le souffle d air froid le ventilateur interne est progressivement allumé par étapes entre un très léger souffle un léger souffle la soufflerie programmée en fonction de l augmentation de la température de l air propulsé Il faut...

Page 16: ... durée doivent l être au début de chaque saison d utilisation La durée de vie du filtre dépend du lieu d installation de l appareil et de son fonctionnement Comment nettoyer les filtres Brosser doucement la poussière ou nettoyer le filtre avec l aspirateur En cas de taches persistantes laver le filtre dans de l eau tiède avec un détergent non abrasif ou dans de l eau pure puis rincer convenablemen...

Page 17: ...e la rotation du moteur est toujours audible par intermit tence après l arrêt du climatiseur Tous les témoins sont éteints sauf le témoin de mise sous tension Lorsque d autres appareils intérieurs sont program més pour le refroidissement l eau d écoulement est amenée à l intérieur Lorsque l eau d écoulement est rassemblée le mécanisme d écoulement entame l opération de drainage Le bruit s arrête r...

Page 18: ...ur une estimation du coût des travaux requis pour le démé nagement de l installation Précaution Lors du déménagement et de la réinstallation du climatiseur veuillez prendre contact avec votre revendeur car une installation défectueuse peut être la cause d électrocution d incendie etc Faire également attention au bruit Lors des travaux d installation choisir un endroit capable de supporter entiè re...

Page 19: ...000 54000 60000 80000 108000 Dimensions Hauteur mm 380 470 in 15 18 9 16 Largeur mm 1195 1250 in 47 1 4 49 1 4 Profondeur mm 900 1120 in 35 7 16 44 1 8 Poids net kg 69 71 100 lb 153 157 221 VENTILA TEUR Débit de l air Faible Haut m3 min 26 5 38 0 26 5 38 0 28 0 40 0 58 0 72 0 cfm 936 1342 936 1342 989 1412 2048 2541 Pression statique externe 3 Pa 208V 100 250 100 250 100 250 70 160 70 160 230V 150...

Page 20: ...ages d usine Séries PEFY P NMHU E F PEFY P30NMHU E F PEFY P54NMHU E F PEFY P72NMHU E F PEFY P96NMHU E F 208V 230V 208V 230V 208V 230V 208V 230V 85 130 85 130 180 260 180 260 PEFY P NMHSU E Modèle Élément PEFY P72NMHSU E PEFY P96NMHSU E Source d alimentation 208 230V 60Hz Capacité 1 Refroidissement kW 21 1 28 1 BTU h 72000 96000 Chauffage kW 23 4 31 7 BTU h 80000 108000 Dimensions Hauteur mm 470 in...

Page 21: ... P24NRMU E Source d alimentation 208 230V 60Hz Capacité 1 Refroidissement kW 1 8 2 3 3 5 4 4 5 3 7 0 BTU h 6000 8000 12000 15000 18000 24000 Chauffage kW 2 0 2 6 4 0 5 0 5 9 7 9 BTU h 6700 9000 13500 17000 20000 27000 Dimensions Hauteur mm 630 in 25 3 16 Largeur mm 886 1006 1246 in 34 15 16 39 5 8 49 1 16 Profondeur mm 220 in 8 11 16 Poids net kg 19 19 20 21 25 27 lb 41 41 45 47 56 60 VENTILA TEUR...

Page 22: ......

Page 23: ......

Page 24: ...ne number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT06893X01 This product is designed and intended for use in the residential commercial and light industrial environment ...

Reviews: