![Mitsubishi Electric CANopen ME3CAN1-L User Manual Download Page 53](http://html.mh-extra.com/html/mitsubishi-electric/canopen-me3can1-l/canopen-me3can1-l_user-manual_238822053.webp)
Buffer Memory Details: CANopen
Mode
Detailed Description of the Module
MELSEC-L Series – CANopen
Module ME3CAN1-L
3 – 31
●
Signed, unsigned and float 32 bit object
Index (Hexadecimal)
Sub-index
(Hex.
Buffer memory address
(Decimal)
Float 32 bit
object
Unsigned 32 bit
object
Signed 32 bit
object
A240
A200
A1C0
1
13000
13001
2
13002
13003
:
:
FE
13506
13507
A241
A201
A1C1
1
13508
13509
:
:
FE
14014
14015
A242
A202
A1C2
1
14016
14017
:
:
04
11022
11023
Tab. 3-27: