Expansion Stages and System Capacity
87
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014
Tab. 37
Average power requirements of terminals
Tip
With the planning application Aastra Plan the power supply available for
terminals is checked automatically.
Terminals
Socket
Output P [mW]
Aastra 5360
1)
1)
Although no longer available, the phone is still supported.
DSI-AD2 interface
280
Aastra 5361
DSI-AD2 interface
680
Aastra 5370
DSI-AD2 interface
680
Aastra 5380
DSI-AD2 interface
820
Aastra 5370, Aastra 5380 with power supply
unit
DSI-AD2 interface
0
Expansion key module Aastra M530
Aastra 5370
110
Expansion key module Aastra M530
Aastra 5380
120
Expansion key module Aastra M535
Aastra 5370, Aastra 5380
0
2)
2)
An Aastra M535 always requires a power supply unit
Dialog 4220
DSI-DASL interface
390
Dialog 4222
DSI-DASL interface
640
Dialog 4223
DSI-DASL interface
660
EKP expansion key module Dialog 4222,
Dialog 4223
45
Radio unit without power supply unitSB-4+
DSI-AD2 interface
1500
3)
3)
The value applies to radio units with hardware version "-2". The value for hardware version "-1" is 300 mW
lower.
Radio unit without power supply unitSB-8
2 DSI-AD2 interfaces
1350
4)
4)
The value applies to each interface and to radio units with hardware version "-2". The value per interface for
radio units with hardware version "-1" is 150 mW lower.
Radio unit with power supply unit SB-4+/SB-8
1 or 2 DSI-AD2 interfaces
< 100
Office 10
DSI-AD2 interface
340
Office 25
DSI-AD2 interface
380
Office 35
DSI-AD2 interface
280
5)
5)
The value applies to phones with hardware version "-2". The value for phones with hardware version "-1" is
60 mW lower.
Office 45/45pro
DSI-AD2 interface
Office 45pro power supply unit
DSI-AD2 interface
< 10
Expansion key module (EKP)
Office 35, Office 45
80
Alphanumerical keyboard (AKB)
Office 35, Office 45
20
ISDN terminal
BRI-S interface
approx. 500
6)
6)
The value depends greatly on the terminal type.
Analogue terminals
FXS interface
approx. 500