Installation
162
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014
Tab. 77
Status LED on the Ethernet interfaces
Cable Requirements
Use commercial Cat. 5 cable, or choose a cable type with the following characteris-
tics:
Tab. 78
Requirements for an Ethernet cable
See also:
For more information about the Ethernet interface on the application
card, see the CPU2-S application card installation manual.
Green LED
Yellow LED
Speed
State
On
On
10 Mbit/s
Port has a connection with the network
flashing
flashing
10 Mbit/s
Port is receiving or sending data
On
Off
100 Mbit/s
Port has a connection with the network
flashing
Off
100 Mbit/s
Port is receiving or sending data
Off
On
1 Gbit/s
Port has a connection with the network
Off
flashing
1 Gbit/s
Port is receiving or sending data
Core pairs
cores
4
2
Stranded
yes
Wire diameter, core
0.4...0.6 mm
Screening
yes
Category
Cat. 5 minimum