Safety, Operation, & Maintenance Manual
Linear Cut Processing Systems
74
4.
Remove the stainless-steel topper from the round table in the saw unit to
expose the 1/2” FHCS that attaches to the bearing.
5.
Remove the motor side bearing bolts from the top side and then remove the
1/2" aluminum spacer that is between the bearing and the tabletop. Also loosen
the bolts indicated below which will cause the pivot shaft assembly to droop –
this is to assist in belt replacement. There is no need to remove any bearings
from the shaft.