MIRKA AIROS Electrical Manual Download Page 10

10

 

Mirka® AIROS  •  77 mm (3"), 125 mm (5") & 150 mm (6")  •  Electrical manual

Holding registers (F3, F6, F16)

Address

Data type

Name

Description

40001–40010

Char[20]

Device name

Max length 19 printable characters,  
e.g. “AIMD 749474379001”.

40011

Uint16

Speed set-point

Speed set-point, not the actual speed, between 
4,000–10,000 RPM.

40012

Uint16

Operation

Motor drive state, can be a combination of the 
following: 
0x0001 = RUN 
0x0002 = STOP 
0x0004 = ON 
0x0008 = OFF  
0x0010 = TOOL CHANGE START 
0x0020 = TOOL CHANGE END
NOTE: When writing a new state value, the value can 
only be a single state, not a combination of multiple 
states, e.g. ON+RUN cannot be written simultaneously.

40013

Uint16

Slave address

Defaults to 86 but can be changed if needed.

RS-485

PIN

Signal

Description

DSUB-9 male

1

GND

Reference potential, ground of power supply

4

RxD / TxD+

Receive data / Transmit data positive

5

RxD / TxD–

Receive data / Transmit data negative

 

Profinet I/O gateway (Hilscher NT 50-RS-EN)

If the motor drive needs to be connected to a Profinet I/O device the Hilscher NT 50-RS-EN gateway can be used. The 
gateway is connected to the motor drive via the DSUB-9 connector on the gateway and the J1 connector on the motor 
drive. Below is the pinout for the DSUB-9 (X2 connector) found on the gateway:

A pull-up resistor of 10 kΩ is internally connected in the gateway to “RxD / TxD+”.
A pull-down resistor of 10 kΩ is internally connected in the gateway to “RxD / TxD–”.

Detailed documentation about the gateway and configuration tools can be downloaded from the Hilscher website: 
https://www.hilscher.com/products/product-groups/gateways/for-the-control-cabinet-ip20/entry-level-gateways/nt-
50-rs-enmbrpns/

Configuration

The gateway comes pre-configured from Mirka as a Profinet I/O slave device. The “SYCON.net” software from Hilscher 
can be used to re-configure the device. The “Ethernet Device Setup” software from Hilscher can be used to change 
the network configuration, use the DCP protocol. The IP address usually needs to be re-assigned after a configuration 
change.

The default configuration can be downloaded from the Mirka website www.mirka.com

Default network configuration

IP ADDRESS

192.168.2.191

SUBNET MASK

255.255.255.0

DEFAULT GATEWAY

0.0.0.0

DEVICE NAME

nt50enpns

1

4
5

Summary of Contents for AIROS

Page 1: ......

Page 2: ...ver any damage caused or resulting from transport receipt of delivery installation commissioning misuse neglect in usage or maintenance accidents exposure to extreme unacceptable ambient temperature a...

Page 3: ...way addon module J2 J1 J5 J6 J3 J4 General Connect the 48 VDC power supply to the motor drive J2 connector Connect the tool to the motor drive J3 and J7 connector Modbus RTU interface Use the J1 conne...

Page 4: ...Dimensions Motor drive 72 x 30 x 200 mm W x H x D Motor drive mounted in DIN rail holder 95 x 55 x 210 mm W x H x D Safety instructions Electrical installation must be carried out by a competent elect...

Page 5: ...It is recommended to use 10 mm ferrules with plastic sleeve for each wire that is attached to any of the connectors The wires can then easily be pushed into the connectors and released with the help...

Page 6: ...lave address indicator bit 1 D3 Speed set point indicator lit if 5 000 rpm Modbus RTU slave address indicator bit 2 D4 Tool status indicator Lit red when the tool is stopped lit green when the tool is...

Page 7: ...Jumper description Jumpers Default Description JP1 Not set Reserved for future use JP2 Not set If set a terminating resistor of 270 is connected across Modbus RTU pins A and B JP3 Not set If set a pu...

Page 8: ...TU over RS 485 is used to communicate with the motor drive The motor drive is configured as a Modbus RTU slave device and the default slave address is 86 The slave address can be changed if it conflic...

Page 9: ...ber of times the run time has been more than 60 seconds 30012 Uint16 Usage count medium The number of times the run time has been between 20 and 60 seconds 30013 Uint16 Usage count short The number of...

Page 10: ...ilscher NT 50 RS EN gateway can be used The gateway is connected to the motor drive via the DSUB 9 connector on the gateway and the J1 connector on the motor drive Below is the pinout for the DSUB 9 X...

Page 11: ...ly monitor the average speed average current tool temperature motor drive temperature and the alarm status flag This will help to detect if there are any issues present during operation Profinet I O t...

Page 12: ...is considered high if a voltage between 15 33 VDC is applied to the input pin The input is considered low if the voltage is below 12 VDC or if the input is left floating The GND pin of connector J6 mu...

Page 13: ...before starting the new tool Protection features The motor drive will momentarily slow down the tool to 4 000 rpm if the motor drive temperature rises above 117 C or the tool temperatures rises above...

Page 14: ...ave address set the JP13 jumper and use indicators D2 D3 D17 D22 to read the current address Profinet I O gateway communication is not working Check the gateway network configuration Check the gateway...

Page 15: ......

Page 16: ...India Pvt Ltd Italy Mirka Italia s r l Cafro S p A Mexico Mirka Mexicana S A de C V Russia Mirka Rus LLC Singapore Mirka Asia Pacific Pte Ltd Spain Mirka Ib rica S A U Sweden Mirka Scandinavia AB Tur...

Reviews: