background image

QMP-5100B and QMP-5101B Installation and Operation Instructions

7

Paging Operation

This section describes the controls and indicators on the QMP-5100B and QMP-5101B Master Paging Modules.

QMP-5100B/QMP-5101B Displays

AC ON

Indicates that AC Power is present, green LED, illuminates steadily.

Common Trouble

Indicates any QX-5000 Trouble, flashes, amber LED.

Mic Trouble

Indicates a Microphone Trouble, flashes, amber LED.

Mic Level

Indicates the Paging Audio Level, green LED.

Amplifier Trouble

Indicates any QX-5000 Amplifier internal Trouble.

Circuit Trouble

Indicates any QX-5000 Amplifier field wiring Trouble.

Remote Failure

Indicates an RS-485 Communications Failure.

Page Inhibit

Indicates that Mic or Warden Paging is Inhibited.

Digitized Messages

Indicates that the Digitized Voice message is active, green LED, illuminates steadily.

All-Call

Indicates that the All-Call function is active, green LED, illuminates steadily. This LED 
will not function if the DIP Switch SW1-5 is set to ON.

All-Call Minus

Indicates that the All-Call Minus function is active, green LED, illuminates steadily.  
This LED will not function if the DIP Switch SW1-5 is set to ON.

Warden Page

Indicates that the Warden Page function is active, green LED, illuminates steadily.

QMP-5100B/QMP-5101B Controls

Reset

Performs a Reset of the QMP-5100B/5101B only 

(not the fire alarm)

.

Lamp Test

Momentarily activates all LED Indicators.

All-Call

Selects all Zones for Voice Paging. This button will not function if DIP Switch SW1-5 
Automatic All-Call is set to ON.

All-Call Minus

Inverts the selection of Zones for Voice Paging.  This button will not function if DIP 
Switch SW1-5 Automatic All-Call is set to ON.

Microphone PTT

The microphone’s PTT (push-to-talk) button, when depressed, causes voice paging 
(from the microphone) to be enabled to all Zones selected for paging, unless Page 
Inhibit is active. 

Note that pressing PTT will not result in any paging activity 

unless there are Zones selected for Paging.

Warden Page

Causes voice paging from the Firefighters’ Telephone (if connected) to be enabled to 
all Zones selected for paging. 

Note that pressing PTT will not result in any paging 

activity. Note also that there must be an active Firefighters’ Telephone 
connection for Warden Paging to occur.

Digitized Messages

This button does not function.

Summary of Contents for QMP-5100B Series

Page 1: ...ior notice U S A 42 20 Steve Reynolds Blvd Unit 17 Norcross Atlanta GA 30093 Tel 1 888 660 4655 Fax 1 888 660 4113 www mircom com QMP 5100B and QZP 5100 Series Firefighters Master Paging Module and An...

Page 2: ......

Page 3: ...oduction 1 Mounting 1 Labels 1 Paging Modules 2 Single Stage Operation 4 Two Stage Operation 4 QMP 5100B QMP 5101B Paging Wiring 5 QMP 5100B and QMP 5101B Paging Configuration 6 Paging Operation 7 QMP...

Page 4: ...Contents ii...

Page 5: ...io Paging Zones for ease of ribbon cable connection Labels Slide in labels which are supplied with the QMP 5100B and QMP 5101B as NP 776 E1 E2 English or F1 F2 French are to be separated and inserted...

Page 6: ...ter Paging Module See also the section Paging Operation The QMP 5101B Master Paging Module has a ribbon cable connection to the first QZP 5101 Zone Module and wiring terminals for connection to the QI...

Page 7: ...MPLIFIER TROUBLE CIRCUIT TROUBLE RESET LAMP TEST DIGITIZED MESSAGES P3 P2 SW1 SW2 1 8 1 1 1 8 S S MIC IN MIC OUT PTT IN PTT IN 24VDC INPUT 24VDC OUTPUT RS 485 INTERFACE INPUT I S I OUTPUT I S I CONNEC...

Page 8: ...There are two buttons and three LEDs per Zone The middle amber LED beside the top button indicates Zone Trouble The upper green LED by the top button indicates whether that Zone is selected for Voice...

Page 9: ...llowed The 120 ohm End of Line Resistor on the RS 485 Output terminals is removed on all except the last wired Module MIC MIC SHLD 18 22 AWG Twisted Shielded Pair RS485 RS485 SHLD 18 22 AWG Twisted Sh...

Page 10: ...F OFF ERROR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 DIP Switch SW 1 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF OFF ON ON ON ON OFF OFF...

Page 11: ...ve green LED illuminates steadily This LED will not function if the DIP Switch SW1 5 is set to ON Warden Page Indicates that the Warden Page function is active green LED illuminates steadily QMP 5100B...

Page 12: ...operative while it does not have power Power interruptions of any length are often accompanied by voltage fluctuations which may damage electronic equipment such as a fire alarm system After a power i...

Page 13: ...s televisions air conditioners or other appliances or passing traffic Audible notification appliances however loud may not be heard by a hearing impaired person Telephone Lines If telephone lines are...

Page 14: ...s caused by failure to provide a suitable installation environment for the products damage caused by use of the products for purposes other than those for which it was designed damage from improper ma...

Page 15: ...information is accurate as of the date of publishing and is subject to change or revision without prior notice at the sole discretion of the Company WARNING Mircom Technologies Ltd recommends that the...

Page 16: ...5 660 4113 Mircom 2011 Printed in Canada Subject to change without prior notice www mircom com U S A 4575 Witmer Industrial Estates Niagara Falls NY 14305 Tel 888 660 4655 905 660 4655 Fax 905 660 411...

Reviews: