background image

-15-

WARRANTY

MIRCOM Technologies Ltd., manufactured equipment is guaranteed to be free of defects in material
and workmanship for a period of one (1) year from the date of original shipment. MIRCOM will repair
or replace, at its option, any equipment which it determines to contain defective material or
workmanship. Said equipment must be shipped to MIRCOM prepaid. Return freight will be prepaid by
MIRCOM. We shall not be responsible to repair or replace equipment which has been repaired by
others, abused, improperly installed, altered or otherwise misused or damaged in any way. Unless
previously contracted by MIRCOM, MIRCOM will assume no responsibility for determining the defective
or operative status at the point of installation, and will accept no liability beyond the repair or
replacement of the product at our factory authorized service depot.

Head Office:

U.S.A. Distribution Centre:

MIRCOM Technologies Ltd.

MIRCOM Technologies Inc.

 25 Interchange Way

60 Industrial Parkway

 Vaughan, Ontario

Cheektowaga, New York

 Canada L4K 5W3

U.S.A. 14227

Telephone: (905) 660-4655

Phone Toll Free: (888) 660-4655

FAX Toll Free: (888) 660-4113

Web Page: http://www.mircom.com

Summary of Contents for FA-1025U

Page 1: ...ecifications contained in this manual are subject to change without prior notice by the manufacturer FA 1025U Fire Alarm Control Panel INSTALLATION and OPERATION MANUAL 1998 by Mircom Technologies Lim...

Page 2: ......

Page 3: ...5 5 BATTERY FAULT LED 3 5 6 GROUND FAULT LED 3 5 7 REMOTE LAMP FAIL LED 3 5 8 SIGNAL TROUBLE LED 3 6 SEQUENCE OF OPERATION 6 1 NORMAL 3 6 2 ALARM 3 6 3 SIGNAL SILENCE 3 6 4 RESET 3 7 SYSTEM CHECKOUT...

Page 4: ......

Page 5: ...l and place the panel over the screws Install the bottom screws and tighten down all four screws For flush mounting make the wall cut out according to the panel dimensions Remove the control panel doo...

Page 6: ...power is connected to the terminal block above the transformer Use GEL CELL or SEALED LEAD ACID type of batteries only Connect the batteries after power up Use 24V 4AH batteries for 24 hours standby...

Page 7: ...MAL All indicators are normally OFF except for the green A C On LED 6 2 ALARM A red zone alarm LED will illuminate steadily for incoming alarm 6 3 SIGNAL SILENCE If the 60 second signal silence inhibi...

Page 8: ...zzer should sound intermittently the common trouble LED flash indicating battery fault 3 Connect the batteries carefully observing the correct polarity 4 The common trouble LED should extinguish If th...

Page 9: ...5 FIGURE 1 BACKBOX FLUSH TRIM MOUNTING DETAILS...

Page 10: ...6 FIGURE 2 CIRCUIT BOARD LAYOUT...

Page 11: ...7 FIGURE 3 DETECTION AND SIGNAL WIRING INSTRUCTION...

Page 12: ...8 FIGURE 4 WIRING TABLE FOR DETECTION ZONE...

Page 13: ...9 FIGURE 5 WIRING TABLE FOR BELLS AND HORNS...

Page 14: ...10 FIGURE 6 ALARM TROUBLE RELAY CONTACTS AND REMOTE ANNUNCIATION WIRING INSTRUCTION...

Page 15: ...00 003 SYSTEM SENSOR PSD 7131 70 201000 005 1400 A PSD 7130 70 201000 001 MIRTONE 2400 A 73471 PSD 7130 70 201000 002 1451 A B401B 73494 PSD 7130 70 201000 003 1451 A B406B 73575 PSD 7130 70 201000 00...

Page 16: ...00 0 10 mA 702E 702U 1451 B401B A A 0 12 mA 712U 701E 701U S10A S00 0 10 mA 702E 702U 1451 B406B A A 0 12 mA 713 5U 701E S10A S00 0 10 mA 701U 702E 702U 1451DH DH400 A A 0 12 mA 713 6U 701E S10A S00 0...

Page 17: ...2475W FR NS4 24110W FR RS 2415W FR RSS 241575W FR RSS 2415W FR RSS 241575W FR RSS 2430W FR RSS 2475W FR RSS 24110W FR RSS 2415C FW RSS 2430C FW RSS 2475C FW RSS 24100C FW MT 12 24 ULC MT 24 LS VFR UL...

Page 18: ...et 2 Sig X 0 114 0 200 RTI 1 Remote Trouble Indicator X 0 035 0 035 2 Wire Smoke Detectors X 0 0001 0 090 0 090 4 Wire Smoke Detectors X Signal Load bells horns strobes and etc Total currents Add abov...

Page 19: ...n repaired by others abused improperly installed altered or otherwise misused or damaged in any way Unless previously contracted by MIRCOM MIRCOM will assume no responsibility for determining the defe...

Page 20: ......

Reviews: