NV9642 Control Panel • User’s Guide
65
6. GPIO
Configuring Outputs
Click on a button under ‘Outputs’ to configure one of the 4 tally outputs.
Click on a button under ‘Inputs’ to configure one of the 8 tally inputs.
S
There are no actual GPIO
buttons
on the NV9642 control panel.
Configuring Outputs
Clicking an output button (one of 4) displays a “Relay Rule” dialog for the output:
Figure 6-4. Relay Rule Dialog
In this dialog, you create a Boolean expression involving sources destinations, port status, and GPI
(input) status. When the conditions of the Boolean expression are met (i.e., the expression is “true”)
the relay closes. When the conditions are not met, the relay opens. Figure 6-4 shows one such Bool-
ean expression.
Boolean expressions comprise
terms
and
operators
. The operators include those indicated on the
left: AND, OR, and NOT. Expressions can be parenthesized to control the order of evaluation.
Operator precedence is normally NOT > AND > OR. All parenthesized expressions are evaluated
first; expressions in nested parentheses are evaluated before those in outer parentheses.
Terms (i.e., operands) are generated by choosing entries in the other fields in this dialog and click-
ing ‘ADD’. The example shows the following:
Dest. Device:
MON2
Dest. Level:
SD
Source Device: CAM1
Source Level: SD
Choosing these items (and clicking ADD) produces the Boolean sub-expression:
SD on CAM1 is switched to SD on MON2
term
operator
term
operator
term
Summary of Contents for NV9642
Page 10: ...x Rev 1 0 13 Oct 09 Table of Contents ...
Page 52: ...42 Rev 1 0 13 Oct 09 4 Configuration Global Navigation ...
Page 78: ...68 Rev 1 0 13 Oct 09 6 GPIO Configuring Inputs ...
Page 84: ...74 Rev 1 0 13 Oct 09 7 Technical Details Drawings ...
Page 90: ...80 Rev 1 0 13 Oct 09 8 Misc Topics Ordering Information ...