NV9607 Control Panel • User’s Guide
57
6. GPIO
Chapter 6 provides information about the tally (GPIO) interface. It discusses the following topics:
•
•
•
•
The Interface
The tally interface includes 8 optically isolated inputs and 4 solid-state relay outputs (also optically
isolated). Tally devices you connect to inputs can trigger events
—
through the NV9607
—
in the
router control system. The router control system can trigger events that
—
through the relays in the
NV9607
—
switch your tally devices.
The DB25 connector, labeled “GPI Interface” at the rear of the NV9607 presents the tally signals.
There are 8 input signals and 4 pairs of output signals.
Figure 6-1. GPI Interface
Input
The tally inputs expect contact closure to ground, through the ground pins on the connector, to trig-
ger a GPI input event.
Figure 6-2. GPI Input
When the input transitions off or transitions on, the NV9607 notifies the router control system,
which carries out the task defined for the input (if a task has been configured).
+
+
7 6
3 2
13
3
1
25
14
+
2
1
+
0
5 4
Inputs
1 0
Outputs
Ground
+
+
6
3
14
+
2
1
+
0
7 6
3 2 5 4
1 0
+5V
Optical
Isolation
C
E
+5V
Tally Input
n
to internal bus
10K
Customers
Switch (or
Equivalent
Logic)
Summary of Contents for NV9606
Page 10: ...x Rev 1 0 21 May 10 Table of Contents ...
Page 20: ...10 Rev 1 0 21 May 10 2 Introduction Other NV9607 Functions ...
Page 40: ...30 Rev 1 0 21 May 10 4 Configuration Multi Destination Configuration ...
Page 66: ...56 Rev 1 0 25 May 10 5 Operation Setup Mode ...
Page 72: ...62 Rev 1 1 21 May 10 6 GPIO Configuring Inputs ...
Page 82: ...72 Rev 1 0 21 May 10 8 Misc Topics Power Cord Retention ...
Page 90: ...80 Rev 1 0 18 Aug 10 Index ...