ENC-1103 SDI to Composite/CAV/RGB Encoder
Guide to Installation and Operation
ENC-1103
Page 3 of 19
Example :
-SELECT button pushed twice when there is no input
signal connected to the rear panel and the LED is steady
red:
Use the local control panel to access the detailed
status report shown in the STATUS menu below.
Serial
Report
GPI
Report
Green Yellow Red
Flashing
Red
No input signal presence
Reference
mismatch
No
reference
No audio group 1
No audio group 2
No audio group 3
No audio group 4
Test
Card System
: Factory default
iControl Interface
The operation of the ENC-1103 may be controlled using
Miranda’s iControl system. This manual describes the
control panels associated with the ENC-1103 and their use.
Please consult the iControl User’s Guide for information
about setting up and operating iControl.
In
iControl Navigator
or
iControl Websites
, double-click on
the ENC-1103 icon to open the control panel.
Note the following features of this panel:
Status Icons
- At the top, to the left of the Miranda logo, are
five status icons that report various aspects of the card’s
operation:
(a) (b) (c) (d) (e)
(a)
this icon shows whether manual card configuration of
this ENC-1103 is on [LOC] or off [REM]
(b) this icon reports the input format (525 or 625 lines)
(c) reference status – green if OK, red if an error has been
detected, white if the reference is absent, yellow if the
input is used as a reference
(d) Audio/video test – green during normal operation,
yellow (as shown) when Test Mode is activated
(e) ABUS multiple card configuration – green if
configuration and card setup are OK; red if there is a
mismatch between the ENC-1103 configuration and the
actual card setup
Move the cursor over an icon to see its current status in the
message area
below the icons. If there is an error status,
the message will appear automatically. If there are multiple
error messages, the display will cycle through them
Panel selection buttons
– the buttons on the left side of the
panel are used to select the contents of the main portion of
the screen. The selected button is highlighted, and the main
screen heading matches the button name. The column of
buttons can be hidden/revealed by clicking the arrow icon at
the left-hand side.
E N C - 1 1 0 3
A L
N O
S I G N