ENC-1103 SDI to Composite/CAV/RGB Encoder
Guide to Installation and Operation
Page 16 of 19
ENC-1103
Copy profile to
section
This line shows other ENC-1103 cards that are available on the iControl network, each identified by App server,
Densité frame and slot number, card type and firmware version.
The
Profile
column shows the same information as is shown for the current card in the Copy profile from line, i.e.
•
Current, User1, User2, User3, User4, User5
The
Select
column includes a checkbox to identify which ENC-1103 cards you wish to copy profiles into from the
current card.
•
For convenience, a
Select all
checkbox is provided in the column header
Click
Copy
to copy the selected profiles from this card into the selected other ENC-1103 cards
•
While the profile copy operation is in progress, the Transfer Status box on the right of the
Copy profile to
line
will indicate
Working
against a yellow background
•
When the profile copy operation is complete, the Transfer Status box on the right of the
Copy profile to
line will
indicate
Succeeded
against a green background
ENC-1103 Menu
Operating Parameter Adjustment
The ENC-1103 has operating parameters which may be adjusted locally at the controller card interface. After
pressing the SELECT button on the ENC-1103 module, use the keys on the local control panel (described in the
Controller card manual) to step through the displayed menu and adjust the parameters. The menus are shown
below; underlined values are factory defaults.
STATUS
NO SIGNAL / SDI 525 / SDI 625
NO EXTERNAL REF / EXTERNAL REF 525 / EXTERNAL REF 625
NO URS / URS 525 / URS 625
REF
MISMATCH
NO AES / AES GROUP: 1234
NO REAR / SINGLE REAR / DOUBLE REAR
OUTPUT : NTSC / PAL /PAL-M / GBR / YUV / BETACAM
)
TEST
A1
MISSING
A2
MISSING
CARD
SYSTEM
HARDWARE
FAILURE
USER PRESET
LOAD
[USER 1 ,USER 2, USER 3, USER 4, USER 5]
SAVE
[USER 1 ,USER 2, USER 3, USER 4, USER 5]
(CONTINUED…)