29
3.6.
Carefully pull the flow valve and switch assembly and the heater tank away from
the case. Make sure that you ease the flow valve and switch assembly off the
motor/pump assembly..
3.7.
Remove the outlet connector from the heater tank.
3.8.
Remove the heater tank from the flow valve and switch assembly.
3.9.
Remove the microswitches from the flow valve and switch assembly.
3.10.
Make a note of the positions of the solenoid wires on top of the heater tank.
Remove the solenoid wires.
3.11.
Remove the flow valve and switch assembly.
3.12.
Refit the components in reverse order. Make sure that the electrical wires are
installed in the correct positions.