![Mira Advance ATL Thermostatic Installation & User Manual Download Page 34](http://html1.mh-extra.com/html/mira/advance-atl-thermostatic/advance-atl-thermostatic_installation-and-user-manual_1804935034.webp)
34
MaInTenanCe
CLEAR
Tradesperson Maintenance - Inlet Filter Cleaning/Replacing
read the section
'Important safety Information'
first.
1.
electrical and water supplies to the
appliance are turned off.
2.
remove the cover screw, cover and
splash guard. disconnect the ribbon
cable from the cover
3.
hold a wrench across the flats
of the metal connector. Unscrew
the filter using another wrench as
shown. Clean or replace the filter
as necessary. Refit the filter making
sure it is screwed fully home.
Do not
overtighten
.
4.
Make sure all plumbing connections
are sealed before restoring the water
supply.
Re-prime the appliance
(refer to
'Installation'
) before
restoring the electricity supply. Refit
the splash guard, ribbon cable and
cover.
user Maintenance - Cleaning
Many household cleaners contain abrasives and chemical
substances, and should not be used for cleaning plated or plastic
fittings. These finishes should be cleaned with a mild washing
up detergent or soap solution, and then wiped dry using a soft
cloth.
note!
If any of the button lights are flashing or pulsing continuously
(in excess of 15 seconds) this may indicate that the button is stuck,
this can be avoided by keeping the unit clean.
poor shower performance can be avoided by cleaning the
spray plate. Use thumb or soft cloth to wipe rubber nozzles. The
showerhead must be descaled regularly to stop the showerhead
getting blocked.