Basic supply Checks:
check there is electricity still supplied to the appliance
•
(lights
and/or beeps will confirm this). If in any doubt, contact a qualified
electrician. If a short power cut has occurred during use, the shower
will automatically reset as above and be ready when the blue light
stops pulsing.
check all plumbing isolator valves to the shower are fully open.
•
a section of supply pipe may be preheating the cold water supply to
•
the shower e.g. cold water supply pipe is running through a loft or is
adjacent to hot water pipes.
a section of supply pipe is frozen. allow to thaw and insulate the
•
pipe.
recommission the shower (refer to section:
•
'Commissioning'
).
In rare cases,
•
or if the unit has been powered down incorrectly
,
hot water may be retained within the shower causing a failure to
continue even though the underlying cause may have been corrected.
allowing the water to cool for approximately 20 minutes before use
should clear this error.
If a failure still continues after all of these checks are complete, and the shower has
once again been reset, and a solution has not been identified in the fault diagnosis
table, then contact a competent tradesperson who can further diagnose the fault.