17
10.
Caution!
do not drill into
buried cables or pipes.
11.
Use template provided
to mark and drill
required fixing holes.
Screws and plugs
are supplied for two
required holes only.
Mira Advance ATL
Attention Installer
IMPORTANT!
The following key details should be read in
conjunction with the Installation and User Guide.
Optional
Fixing Hole
Required
Fixing Hole
1083677-W7-A
© Kohler Mira Limited, May 2007
Optional
For technical support and general enquires,
spare parts and after sales service contact us on:
Telephone : 0870 241 0888
Fax :
01242 282 595
email : [email protected]
Optional
Optional
Leave minimum gap to
install and maintain
Do not
install the appliance where it
may become frozen.
Do not
drill into buried cables or
pipes.
Avoid dust contamination of the
product by using this template to mark
and drill into the wall. Drill appliance
case separately.
Do not
use alternative screws to
secure the cover.
Do not
seal any part of the appliance.
Use the correct supply cable
size. Refer to BS 7671.
Leave minimum gap
to remove cover
Required
Fixing Hole
Thoroughly fl ush the
pipework before connecting
to the appliance.
12.
drill holes through
p l a s t i c c a s e a s
required. route signal
cable to shower drain
pump (if applicable).
Fix appliance to wall.
15.
connect hose and
showerhead, pointing
into bath or tray.
14.
Turn on water supply
and check for leaks.
13.
connect supply pipe.
Do not
overtighten.
Find the whale shower drain
pump transformer and identify
it's type number.
jumper position for Mira
advance aTL drain pump
pcb.
Type: 755.171 = LK1
Type: 755.299 = LK2
13. Mira advance aTL standard extra & Flex extra variants only!