WALLMOUNT CONFIGURATION

The wallmount configuration

 

allows the user to mount the UPS on the wall.  There is

a wallmount bracket kit available for the UPS.  The kit includes two wall mounting
brackets, ten retaining screws, and the wallmount template.  

WARNING: 

Use two or

more people when installing the UPS, the UPS is extremely heavy.  The UPS's side
panels have mounting bracket screw holes for attaching the wall mounting brackets.
1. Once the location of the UPS has been determined, place the UPS on a flat surface

and remove the rackmount brackets from the UPS.

2. The LCD panel can be rotated to read in the up-right position.  Remove the front pa-

nel from the UPS.  On the backside of the front panel, push the LCD panel outwards,
the panel will pop out.  Position the LCD panel so that it reads in the upright position.
Re-install the front panel on the UPS.

WARNING:  

The UPS must be installed in the proper up-right position.  If the UPS is not

installed in the proper up-right position the Batteries will be damaged.  Once the UPS is
placed on the wall, looking at the front panel the YELLOW Battery disconnected label on
the top cover of the UPS MUST be on your left hand side.
3. Align the mounting brackets with the mounting bracket screw holes on the side pan-

els of the UPS and attach with the six retaining screws.

4. Use the template to mark the screw hole position on the wall.  

CAUTION

,

 

you should

always were protective gear for your hands and eyes when operating power tools.

5. Attach the four retaining screws to the wall and make sure that all of the retaining s-

crews are screwed into structural material.  Then clean the area of any loose mate-
rial.  Do not tighten the retaining screws all the way, leave approximately 3/8" of the
retaining screws sticking out.

6. Position the UPS, so that the mounting bracket keyed holes line up with the four ret-

aining screws.  Slide the UPS down until its resting securely on the four retaining s-
crews.

7. Tighten the four retaining screws to secure the UPS to the wall.
8. The Wallmount Configuration is complete.  See Connecting your Equipment.

TOWER CONFIGURATION

The tower configuration allows the user to install the UPS in the up-right position
next to a tower computer.  The tower brackets are provided with the UPS.  

WARNING:

Use two or more people when installing the UPS, the UPS is extremely heavy.
1. Once the location of the UPS has been determined, place the UPS on a flat surface,

remove the rackmount brackets from the UPS and then place the tower brackets in
the desired location.

2. The LCD panel can be rotated to read in the up-right position.  Remove the front pa-

nel from the UPS.  On the backside of the front panel, push the LCD panel outwards,
the panel will pop out.  Position the LCD panel so that it reads in the upright position.
Re-install the front panel on the UPS.

WARNING:  

The UPS must be installed in the proper up-right position.  If the UPS is not

installed in the proper up-right position the Batteries will be damaged.  Once the UPS is
placed in the tower brackets, looking at the front panel the YELLOW Battery discon-
nected label on the top cover of the UPS MUST be on your left hand side.
3. Slide the UPS into the tower brackets.  Make sure that the UPS is stable.
4. The Tower Configuration is complete.  See Connecting your Equipment.

DESKTOP CONFIGURATION

The desktop configuration allows the user to install the monitor, the computer and
the UPS in one single stack.  

WARNING: 

Use two or more people when installing the

UPS, the UPS is extremely heavy.
1. Once the location of the UPS has been determined, place the UPS on a flat surface,

remove the rackmount brackets from the UPS and then place the UPS in the desired
location.

2. Stack the computer and then the monitor on top of  the UPS.  

NOTE:

 Do not stack

the UPS on top of the computer.  The UPS is heavy and may damage the other equ-
ipment.

3. The Desktop Configuration is complete.  See Connecting your Equipment.

Summary of Contents for ED3000RTXL2U

Page 1: ...User s Manual Endeavor LCD RTXL UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000516 R2...

Page 2: ...6 3 Installation 9 4 Operation 15 5 Configurable Parameters Settings 19 6 Obtaining Service 20 7 Troubleshooting 21 8 Replacing the Battery 22 9 Specifications 25 10 Limited Product Warranty 27 A1 De...

Page 3: ...k Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected CAUTION To reduce the risk of electrical shock in conditions where the load equ...

Page 4: ...3 To de energize the UPS completely disconnect the battery Life Support Policy As a general policy we do not recommend the use of any of our products in life support applications where failure or malf...

Page 5: ...ght will turn on and remain on to alert the user that an event has occurred Chapter 2 Controls and Indicators The UPS output is off bPS EPo RPo E24 ECo PAS off The UPS output has been turned on The UP...

Page 6: ...he locking and Always On receptacles Lab eled Load 3 do not support the Load Shedding Function NOTE The lo cking recptacle is not on all models 8 The input circuit breaker will trip in the event the l...

Page 7: ...e units have been installed The rack may become unstable due to the weight distribution 2 The Rackmount Configuration is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERV...

Page 8: ...ng screws Slide the UPS down until its resting securely on the four retaining s crews 7 Tighten the four retaining screws to secure the UPS to the wall 8 The Wallmount Configuration is complete See Co...

Page 9: ...PTIONAL Connect one end of the RJ11 cable to the EPO port and the other end of the RJ11 cable to the EPO switch In the AC or the Battery mode short pin4 to pin5 for approximately 0 5 seconds to shutdo...

Page 10: ...ad 3 does not support the Load Shed ding Function TURNING THE UNIT ON OFF On Off Test Button When the UPS is connected to an AC source and there is an acceptable AC volt age present Press and release...

Page 11: ...are using an External Battery Pack with this UPS series the UPS must be configured so that the UPS will report the correct estimated runtime on the LCD screen and in the Power Monitoring software and...

Page 12: ...n though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cable from the UPS press the On but ton If UPS works normally the software has control of...

Page 13: ...f batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the batteries properly The batteries contain lead and pose a hazard to the environment and human hea...

Page 14: ...ent Short Circuit Protected and Latching Shutdown True Sine Wave Frequency 50 60Hz 0 5Hz unless synchronized to utility Nominal Voltage Adjustable Maximum Power Capacity 0 ms Typical 90 Full Load Rese...

Page 15: ...cus tomer pays for shipping the product to Para Systems Para Systems pays ground freight to ship the product back to the customer Replacement parts and warranty labor will be borne by Para Systems For...

Page 16: ...XL2U Y ED3000RTXL2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date February 1 2017 Robert Calhoun Name Manager Engineering Posi...

Reviews: