Thank you for purchasing this power protection product.  It has been designed
and manufactured to provide many years of trouble free service.  Please read
this manual before installing your Endeavor LCD UPS, models ED1000RTXL2U,
ED1500RTXL2U, ED2000RTXL2U, ED3000RTXL2U as it provides important
information that should be followed during the installation and the maintenance
of the UPS system allowing you to correctly set up your system for the maxi-
mum safety and performance.  Included is information on customer support
and factory service, if it is required.  If you experience a problem with the UPS
system please refer to the Troubleshooting guide in this manual to correct the
problem or collect enough information so that the Technical Support Depart-
ment can assist you.

CAUTION!

  The maximum ambient operating temperature for this UPS series

is 40°C (“0 ~ 40°C” for Ambient Operation).

The external vents and openings on the UPS are provided for ventilation.
To ensure reliable operation of the UPS and to protect the UPS from over-
heating, these vents and openings must not be blocked or covered. Do not
insert any object into any of the vents or openings that may hinder the ve-
ntilation.

Install the UPS system in a well ventilated area, away from excess moistu-
re, heat, dust, flammable gas or explosives.

Leave adequate space (at least 20cm) in the front and at the rear of the
UPS system for proper ventilation.

Do not mount the UPS system with its front or rear panel facing down at
any angle.

 Before usage, you must allow the UPS system to adjust to room temper-

ature (20°C~25°C or 68°F~77°F) for at least one hour to avoid moisture
condensing inside the UPS.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS !

CONSIGNES DE SÉCURITÉ IMPORTANTES

SAUVEGARDEZ CES CONSIGNES!

Veuillez lire ce manuel avant l'installation de l'onduleur modèles ED1000RTXL2U,
ED1500RTXL2U, ED2000RTXL2U, ED3000RTXL2U). Il contient de l'information
importante qui doit être respectée au cours de l'installation et de l'entretien de
l'onduleur et des batteries. Cette information vous permettra de correctement
installer le système pour atteindre son rendement maximum en toute sécurité.

Chapter 1:  Introduction

WARNING:

  

Risk of Electrical Shock.  Hazardous live parts inside these

power supplies are energized from the battery even when the AC input is
disconnected.

CAUTION!

 

 To reduce the risk of electrical shock in conditions where the

load equipment grounding cannot be verified, disconnect the UPS from the
AC wall outlet before installing a computer interface cable.  Reconnect the
power cord only after all signaling connections are made.

CAUTION!  

Connect the UPS to a two pole, three wire grounded AC wall

outlet.  The receptacle must be connected to the appropriate branch protec-
tion (circuit breaker or fuse).  Connection to any other type of receptacle may
result in a shock hazard and violate local electrical codes.  Do not plug the
UPS into extension cords, adapter plugs or surge strips.

CAUTION!  

To reduce the risk of electrical shock with the installation of this

UPS equipment and the connected equipment, the user must ensure that the
combined sum of the AC leakage current does not exceed 3.5mA.

WARNING:

  

This Uninterruptible Power Supply contains potentially hazard-

ous voltages.  Do not attempt to disassemble the UPS beyond the battery
replacement procedure.  This UPS contains no user serviceable parts.  Re-
pairs and Battery replacement must be performed by

 QUALIFIED SERVICE

PERSONNEL ONLY.

CAUTION!

  To reduce the risk of fire, connect only to a utility powered

circuit provided with 20 / 30 amperes maximum branch circuit over-current
protection in accordance with the National Electric Code, ANSI/NFPA 70.

WARNING:  Qualified Service Personnel ONLY 

must perform the Installa-

tion and Servicing of these UPS systems.  MINUTEMAN accepts no liabilities
and is not limited to: injury to the Service Personnel, or damages to; the UPS,
or the connected equipment caused by the incorrect installation or servicing
of the UPS system.

CAUTION!

  This UPS series is 

ONLY

 intended to be installed in an indoor

temperature controlled environment that is free of conductive contaminants.
This UPS series is not intended for use in a computer room as defined in the
Standard for the Protection of Electronic Computer/Data Processing Equip-
ment ANSI/NFPA 75.

NOTE:

  These UPSs are shipped with the batteries disconnected.  The batter-

ies must be connected before putting these UPSs into service.  Refer to Sec-
tion 3 "Installation" for connecting the batteries.

CAUTION!  

DO NOT USE THE MOUNTING BRACKETS TO LIFT THE

UPS.

  The mounting brackets are 

ONLY

 for securing the UPS to the rack.

Summary of Contents for ED3000RTXL2U

Page 1: ...User s Manual Endeavor LCD RTXL UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000516 R2...

Page 2: ...6 3 Installation 9 4 Operation 15 5 Configurable Parameters Settings 19 6 Obtaining Service 20 7 Troubleshooting 21 8 Replacing the Battery 22 9 Specifications 25 10 Limited Product Warranty 27 A1 De...

Page 3: ...k Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected CAUTION To reduce the risk of electrical shock in conditions where the load equ...

Page 4: ...3 To de energize the UPS completely disconnect the battery Life Support Policy As a general policy we do not recommend the use of any of our products in life support applications where failure or malf...

Page 5: ...ght will turn on and remain on to alert the user that an event has occurred Chapter 2 Controls and Indicators The UPS output is off bPS EPo RPo E24 ECo PAS off The UPS output has been turned on The UP...

Page 6: ...he locking and Always On receptacles Lab eled Load 3 do not support the Load Shedding Function NOTE The lo cking recptacle is not on all models 8 The input circuit breaker will trip in the event the l...

Page 7: ...e units have been installed The rack may become unstable due to the weight distribution 2 The Rackmount Configuration is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERV...

Page 8: ...ng screws Slide the UPS down until its resting securely on the four retaining s crews 7 Tighten the four retaining screws to secure the UPS to the wall 8 The Wallmount Configuration is complete See Co...

Page 9: ...PTIONAL Connect one end of the RJ11 cable to the EPO port and the other end of the RJ11 cable to the EPO switch In the AC or the Battery mode short pin4 to pin5 for approximately 0 5 seconds to shutdo...

Page 10: ...ad 3 does not support the Load Shed ding Function TURNING THE UNIT ON OFF On Off Test Button When the UPS is connected to an AC source and there is an acceptable AC volt age present Press and release...

Page 11: ...are using an External Battery Pack with this UPS series the UPS must be configured so that the UPS will report the correct estimated runtime on the LCD screen and in the Power Monitoring software and...

Page 12: ...n though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cable from the UPS press the On but ton If UPS works normally the software has control of...

Page 13: ...f batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the batteries properly The batteries contain lead and pose a hazard to the environment and human hea...

Page 14: ...ent Short Circuit Protected and Latching Shutdown True Sine Wave Frequency 50 60Hz 0 5Hz unless synchronized to utility Nominal Voltage Adjustable Maximum Power Capacity 0 ms Typical 90 Full Load Rese...

Page 15: ...cus tomer pays for shipping the product to Para Systems Para Systems pays ground freight to ship the product back to the customer Replacement parts and warranty labor will be borne by Para Systems For...

Page 16: ...XL2U Y ED3000RTXL2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date February 1 2017 Robert Calhoun Name Manager Engineering Posi...

Reviews: