background image

27

26

BATTERY SYSTEM

Typical Recharge Time

Typical Battery Life

Battery Module

3-5 years, depending on discharge cycles and ambient temp

BM0035

BM0037

8-hours to 90% after a full load discharge

Battery Type

Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid

Runtime: Full Load (minutes)

Runtime: Half Load (minutes)

12

11

4

3

SURGE PROTECTION AND FILTERING

Audible Noise at 1 m (3 ft.)

10/100 Base-T surge protection
let-through (as a percentage of an
a/-2 kV 1.2/50 us, 500 a 8/
20 uS test)

Telephone line surge protection
let-through (as a percentage of an
a/-2 kV 1.2/50 us, 500a 8/
20 uS test)

Noise Filter

Surge voltage let-through (as a
percentage of an applied ANSI
C62.41 Cat. A +/-2 kV)

Surge Response Time

Surge Current Capability

Surge Energy Rating

1000 Joules

0 ns (instantaneous) normal mode; <5 ns common mode

<5%

normal and common mode EMI/RFI suppression

<45 dBA

<1%

<5%

6500 Amps total

ENVIRONMENTAL

Operating Temperature (max)

Operating/Storage Humidity

Operating Elevation

0 to 40

°

C (+32 to +104

°

F)

95% Non-Condensing

0 to 3,000m (0 to +10,000 ft)

PHYSICAL

Weight - Net

Size - Net   L X W X H
(rackmount brackets installed)

Size - Shipping
L X W X H

Weight - Shipping

13.3 x 19.0 x 3.5"
339x482.6x89mm

23.6 x 20.0 x 8.8"
599x508x223mm

REGULATORY COMPLIANCE

Safety and Approvals

cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 /
R: 2014), FCC Class B (1K & 1.5K), FCC Class A (2K & 3K), CE
certified, Energy Star certified, RoHS2 (EU Directive 2011/65/EU)

Storage Elevation

0 to 15,000m (0 to +50,000 ft)

Storage Temperature

-15 to +45

°

C (+5 to +113

°

F)

BM0036

BM0032

12

3.5

12

3

<60 dBA

24.5 x 19.0 x 3.5"
621x482.6x89mm

39.3 x 23.6 x 8.5"
1000x600x217mm

70.5 lbs
32.0 Kgs

90.4 lbs
41.0 Kgs

47.6 lbs
21.6 Kgs

56.0 lbs
25.4 Kgs

29.3 lbs
13.3 Kgs

37.0 lbs
16.8 Kgs

45.9 lbs
20.8 Kgs

54.2 lbs
24.6 Kgs

External Battery Pack Options

BP24RTXL
BP24RTEXL

BP48RTXL
BP48RTEXL

BP72RTXL
BP72RTEXL

17.0 x 19.0 x 3.5"
432x482.6x89mm

23.5 x 21.6 x 8.8"
597x549x223mm

Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and
operated within specified conditions, against faulty materials or workmanship for a pe-
riod of five (5) years from the date of purchase.  The battery warranty borne by Para
Systems is limited to one (1) set of replacement batteries during the five (5) year war-
ranty period.  For equipment sites within the United States and Canada, this warranty
covers depot repair or replacement of defective equipment at the discretion of Para
Systems.  Depot repair will be from the nearest authorized service center.  The cus-
tomer pays for shipping the product to Para Systems.  Para Systems pays ground freight
to ship the product back to the customer.  Replacement parts and warranty labor will be
borne by Para Systems.  For equipment located outside of the United States and Canada,
Para Systems only covers faulty parts.  Para Systems products that are depot repaired
or replaced pursuant to this warranty shall only be warranted for the unexpired portion of
the warranty applying to the original product.  This warranty applies only to the original
purchaser who must have properly registered the product within 10 days of purchase.

The warranty shall be void if (a) the equipment is damaged by the customer, is improp-
erly used, is subjected to an adverse operating environment, or is operated outside the
limits of its electrical specifications; (b) the equipment is repaired or modified by anyone
other than Para Systems or Para Systems approved personnel; or (c) has been used in
a manner contrary to the product’s User's Manual or other written instructions.

Any technical advice furnished before or after delivery in regard to use or application of
Para Systems’ equipment is furnished without charge and on the basis that it represents
Para Systems’ best judgment under the circumstances, but it is used at the recipient’s
sole risk.

EXCEPT AS PROVIDED HEREIN, PARA SYSTEMS MAKES NO WARRANTIES, EX-
PRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PURPOSE.  Some states do not permit limitation of implied
warranties; therefore, the aforesaid limitation(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE
FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSI-
BILITY OF SUCH DAMAGE.  Specifically, Para Systems is not liable for any costs, such
as; labor for on-site installation, on-site maintenance or on-site service, lost profits or
revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, cost
of substitutes, claims by third parties, or otherwise.  The sole and exclusive remedy for
breach of any warranty, expressed or implied, concerning Para Systems’ products and
the only obligation of Para Systems hereunder, shall be depot repair or replacement of
defective equipment, components, or parts; or, at Para Systems’ option, refund of the
purchase price or substitution with an equivalent replacement product.  This warranty
gives you specific legal rights and you may also have other rights which vary from state
to state.

No employee, salesman, or agent of Para Systems is authorized to add to or vary the
terms of this warranty.

Chapter 10:  Limited Product Warranty

Summary of Contents for ED3000RTXL2U

Page 1: ...User s Manual Endeavor LCD RTXL UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000516 R2...

Page 2: ...6 3 Installation 9 4 Operation 15 5 Configurable Parameters Settings 19 6 Obtaining Service 20 7 Troubleshooting 21 8 Replacing the Battery 22 9 Specifications 25 10 Limited Product Warranty 27 A1 De...

Page 3: ...k Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected CAUTION To reduce the risk of electrical shock in conditions where the load equ...

Page 4: ...3 To de energize the UPS completely disconnect the battery Life Support Policy As a general policy we do not recommend the use of any of our products in life support applications where failure or malf...

Page 5: ...ght will turn on and remain on to alert the user that an event has occurred Chapter 2 Controls and Indicators The UPS output is off bPS EPo RPo E24 ECo PAS off The UPS output has been turned on The UP...

Page 6: ...he locking and Always On receptacles Lab eled Load 3 do not support the Load Shedding Function NOTE The lo cking recptacle is not on all models 8 The input circuit breaker will trip in the event the l...

Page 7: ...e units have been installed The rack may become unstable due to the weight distribution 2 The Rackmount Configuration is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERV...

Page 8: ...ng screws Slide the UPS down until its resting securely on the four retaining s crews 7 Tighten the four retaining screws to secure the UPS to the wall 8 The Wallmount Configuration is complete See Co...

Page 9: ...PTIONAL Connect one end of the RJ11 cable to the EPO port and the other end of the RJ11 cable to the EPO switch In the AC or the Battery mode short pin4 to pin5 for approximately 0 5 seconds to shutdo...

Page 10: ...ad 3 does not support the Load Shed ding Function TURNING THE UNIT ON OFF On Off Test Button When the UPS is connected to an AC source and there is an acceptable AC volt age present Press and release...

Page 11: ...are using an External Battery Pack with this UPS series the UPS must be configured so that the UPS will report the correct estimated runtime on the LCD screen and in the Power Monitoring software and...

Page 12: ...n though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cable from the UPS press the On but ton If UPS works normally the software has control of...

Page 13: ...f batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the batteries properly The batteries contain lead and pose a hazard to the environment and human hea...

Page 14: ...ent Short Circuit Protected and Latching Shutdown True Sine Wave Frequency 50 60Hz 0 5Hz unless synchronized to utility Nominal Voltage Adjustable Maximum Power Capacity 0 ms Typical 90 Full Load Rese...

Page 15: ...cus tomer pays for shipping the product to Para Systems Para Systems pays ground freight to ship the product back to the customer Replacement parts and warranty labor will be borne by Para Systems For...

Page 16: ...XL2U Y ED3000RTXL2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date February 1 2017 Robert Calhoun Name Manager Engineering Posi...

Reviews: