NOTICE:   

This equipment has been tested and found to comply with the limits

for a Class A and/or B computing device in accordance with the specifications
in Subpart J of Part 15 of FCC Rules and the Class A and/or B limits for radio
noise emissions from digital apparatus set out in the Radio Interference of the
Canadian Department of Communications.  These limits are designed to pro-
vide reasonable protection against such interference in a residential installa-
tion.  This equipment generates and uses radio frequency and if not installed
and used properly, that is, in strict accordance with the manufacturer's in-
structions, this equipment may cause interference to radio and television re-
ception.  If this equipment does cause interference to radio or television re-
ception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:

Re-orient the receiving antenna.

Relocate the computer with respect to the receiver.

Move the computer away from the receiver.

Plug the computer into a different outlet so that the computer and receiver
are on different branch circuits.

Shielded communications interface cables must be used with this product.

WARNING: 

 

Changes or modifications to this unit not expressly approved

by the party responsible for compliance could void the user's authority to
operate the equipment.

ON / OFF / TEST BUTTON:  

Press and release the On/Off/Test

button during the audible alarm's first beep to turn the UPS On.  Once
the UPS successfully passes the twenty-second self test the load will
be powered.

Press and release the On/Off/Test button during the audible alarm's
first beep to turn the UPS Off.  The UPS will continue to charge the
batteries whenever it is plugged into a wall outlet and there is an
acceptable AC voltage present.

To perform a ten-second battery test:  With the UPS in the  AC
normal mode, press and hold the On/Off/Test button until the audible
alarm sounds four beeps, and then release.  During the test, the
UPS will switch to the Battery mode, the On-Battery icon will illumi-
nate and the alarm will sound.

CAUTION!  

To de-energize the outputs of the UPS:

1.

If the UPS is On press and release the On/Off/Test button.

2.

Disconnect the UPS from the AC wall outlet.

3.

To de-energize the UPS completely, disconnect the battery.

Life Support Policy

As a general policy, we do not recommend the use of any of our products in
life support applications where failure or malfunction of the product can be
reasonably expected to cause failure of the life support device or to signifi-
cantly affect its safety or effectiveness.  We do not recommend the use of any
of our products in direct patient care.  We will not knowingly sell our products
for use in such applications unless it receives in writing assurances satisfac-
tory to us that (a) the risks of injury or damage have been minimized,  (b) the
customer assumes all such risks, and (c) our liability is adequately protected
under the circumstances.

Receiving Inspection

After removing your UPS from its carton, it should be inspected for damage
that may have occurred in shipping.  Immediately notify the carrier and place
of purchase if any damage is found.  Warranty claims for damage caused by
the carrier will not be honored.  The packing materials that your UPS was
shipped in are carefully designed to minimize any shipping damage.  In the
unlikely case that the UPS needs to be returned to the manufacturer, please
use the original packing material.  Since the manufacturer is not responsible
for shipping damage incurred when the system is returned, the original pack-
ing material is inexpensive insurance.  

PLEASE SAVE THE PACKING MATE-

RIALS!

© COPYRIGHT 2017 BY PARA SYSTEMS, INC.

All Rights Reserved. All rights of this User's Manual (“Manual”), including but
not limited to the content, information, and figures are solely owned and re-
served by Para Systems, Inc. (“Para Systems”). The Manual can only be
applied to the operation or the use of this product. Any disposition, duplica-
tion, dissemination, reproduction, modification, translation, extraction, or us-
age of this Manual in whole or in part is prohibited without the prior written
permission of Para Systems. Given that Para Systems will continuously im-
prove and develop the product, changes may be made to the information in
this Manual at any time without obligation to notify any person of such revision
or changes. Para Systems will make all possible efforts to secure the accu-
racy and the integrity of this Manual. Para Systems disclaims any kinds or
forms of warranty, guarantee, or undertaking, either expressly or implicitly,
including but not limited to the completeness, faultlessness, accuracy, non-
infringement, merchantability or fitness for a particular purpose of the Manual.

Summary of Contents for ED3000RTXL2U

Page 1: ...User s Manual Endeavor LCD RTXL UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000516 R2...

Page 2: ...6 3 Installation 9 4 Operation 15 5 Configurable Parameters Settings 19 6 Obtaining Service 20 7 Troubleshooting 21 8 Replacing the Battery 22 9 Specifications 25 10 Limited Product Warranty 27 A1 De...

Page 3: ...k Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected CAUTION To reduce the risk of electrical shock in conditions where the load equ...

Page 4: ...3 To de energize the UPS completely disconnect the battery Life Support Policy As a general policy we do not recommend the use of any of our products in life support applications where failure or malf...

Page 5: ...ght will turn on and remain on to alert the user that an event has occurred Chapter 2 Controls and Indicators The UPS output is off bPS EPo RPo E24 ECo PAS off The UPS output has been turned on The UP...

Page 6: ...he locking and Always On receptacles Lab eled Load 3 do not support the Load Shedding Function NOTE The lo cking recptacle is not on all models 8 The input circuit breaker will trip in the event the l...

Page 7: ...e units have been installed The rack may become unstable due to the weight distribution 2 The Rackmount Configuration is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERV...

Page 8: ...ng screws Slide the UPS down until its resting securely on the four retaining s crews 7 Tighten the four retaining screws to secure the UPS to the wall 8 The Wallmount Configuration is complete See Co...

Page 9: ...PTIONAL Connect one end of the RJ11 cable to the EPO port and the other end of the RJ11 cable to the EPO switch In the AC or the Battery mode short pin4 to pin5 for approximately 0 5 seconds to shutdo...

Page 10: ...ad 3 does not support the Load Shed ding Function TURNING THE UNIT ON OFF On Off Test Button When the UPS is connected to an AC source and there is an acceptable AC volt age present Press and release...

Page 11: ...are using an External Battery Pack with this UPS series the UPS must be configured so that the UPS will report the correct estimated runtime on the LCD screen and in the Power Monitoring software and...

Page 12: ...n though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cable from the UPS press the On but ton If UPS works normally the software has control of...

Page 13: ...f batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the batteries properly The batteries contain lead and pose a hazard to the environment and human hea...

Page 14: ...ent Short Circuit Protected and Latching Shutdown True Sine Wave Frequency 50 60Hz 0 5Hz unless synchronized to utility Nominal Voltage Adjustable Maximum Power Capacity 0 ms Typical 90 Full Load Rese...

Page 15: ...cus tomer pays for shipping the product to Para Systems Para Systems pays ground freight to ship the product back to the customer Replacement parts and warranty labor will be borne by Para Systems For...

Page 16: ...XL2U Y ED3000RTXL2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date February 1 2017 Robert Calhoun Name Manager Engineering Posi...

Reviews: