IVL™
Photon Service Manual AA
44
CAL3:
E-GOBO CALIBRATION
Tools needed:
TrueCon1 cable
Instructions
Diagram
3.1
The purpose of this calibration is
to calibrate the origin of the light
plan between Tilt #8 and Tilt #1.
Make sure that the Globe acrylic
shape is in place.
Turn On the product and go to
Maintenance
→
Calibration
→
Gobo cal
.
3.2
The target for positioning the
origin is represented by the tilt #8
mirror bearing cover.
Once the calibration has started,
a portion of the light plane will
light up.