7.3
Gently unplug the connector from the
MT1-000122 PCB card and slide the
card out.
7.4
Address the MT1-000122 PCB card
according to the MT1-000935 tilt
module you want to replace.
(Switch towards the bottom = 1)
111 = 8
110 = 7
101 = 6
100 = 5
011 = 4
010 = 3
001 = 2
000 = 1
Tilt # 8
7.5
When closing back the module, be
sure that the belt is well positioned
on both pulley, and that the
connector is well plugged.
Tighten screws with a torque of 0.5
Nm.
Do a tilt test (see section
) of the
new addressed tilt to check if
everything works well.
Summary of Contents for IVL PHOTON
Page 1: ...IVL Photon Service Manual AA 1 SERIVCE MANUAL Make the ordinary extraordinary...
Page 10: ...IVL Photon Service Manual AA 10 Labelling diagram...
Page 11: ...IVL Photon Service Manual AA 11 1 Serial number label 2 FCC LABEL...
Page 12: ...IVL Photon Service Manual AA 12 3 SHOCK FIRE LABEL 4 RATING LABEL 5 FDA LABEL 6 MARKING LABEL...
Page 13: ...IVL Photon Service Manual AA 13 7 MANUFACTURER LABEL 8 LASER LABEL 9 PROTECTIVE HOUSING LABEL...
Page 15: ...IVL Photon Service Manual AA 15 Front View Bottom View TRANSPARENT GLOBE...
Page 23: ...IVL Photon Service Manual AA 23 PRODUCT IS NOT EMITING LIGHT OUTPUT...
Page 24: ...IVL Photon Service Manual AA 24 PRODUCT IS EMITTING UNUSUAL ABNORMAL LIGHT...
Page 25: ...IVL Photon Service Manual AA 25 TILT PROBLEM RING PROBLEM...
Page 58: ...IVL Photon Service Manual AA 58 DMX Protocol Mode 1...