34
© MINOTAIR Ventilation Inc. - www.minotair.com
(PENTACARE-V12-OWNER'S MANUAL-2019-Rev-014)
C
ABLE
C
ONFIGURATION
•
Connecting a wall mount digital control is done using a 6-wire telephone cable.
•
The connectors must be 6-position RJ12 (6P6C) type.
•
Maximum cable length for connections is 150 ft. (45 m).
•
One end of the cable connects to the back of the digital control, while the other
end connects to the 6-
position jack labelled “MINO
-
CONTROL”, located on top of
the MINOTAIR.
Figure 21
–
Cable configuration for a single wall mount digital control
•
Warning!
Be sure not to cross endings, as this will render all communications with
the microcontroller impossible. Note that this will not damage the digital control,
but a
NO LINK
message will appear
.
Figure 22
–
Wrong configuration
•
If the installation includes two wallmount digital controls, a cable splitter (optional)
must be connected into the “MINO
-
CONTROL” jack located
on top of the device.
This will double the “MINO
-
CONTROL” jack so that each control can
have its own
cable.
Figure 23 - Cable configuration for two wallmount digital controls