16
© MINOTAIR Ventilation Inc. - www.minotair.com
(PENTACARE-V12-OWNER'S MANUAL-2019-Rev-014)
I
NSTALLATION
P
ROCEDURES
I
MPORTANT
I
NSTALLATION
R
EQUIREMENTS
P
ERSONAL
S
AFETY
•
Wear safety glasses when installing the MINOTAIR.
•
Follow professional safety standards and all local regulations.
R
EGULATIONS
•
WARNING!
The MINOTAIR should be installed in accordance with the local
building codes that are in effect. In absence of such requirements, it is advisable to
check with local authorities having jurisdiction in your area.
D
EVICE
I
NSPECTION
•
WARNING!
Do not power on the device at this point.
•
Inspect the exterior of the device to make sure it is not damaged.
•
Make sure the panel, the hinges, the damper, the vents, the fan blades, the housing
and the installation hooks are in good condition.
•
Any damage sustained during transport must be reported within 24 hours of
delivery.
C
HOOSING WHERE TO INSTALL THE
MINOTAIR
•
Choose an accessible location that will allow and facilitate maintenance and repairs.
•
Avoid lounging areas, offices and bedrooms. It is recommended to soundproof the
selected location if it is too close to rooms where quietness is desired. In this case,
use a solid core door and affix a rubber door sweep (weather strip) at its bottom to
seal the space between the bottom of the door and floor. Do not use louvred or
accordion doors as they have no soundproofing property.
•
The device must be installed indoor, never outside, and the location must maintain
an indoor temperature between 16°C and 27°C (60°F and 80°F).
•
The device must be located near a 120 VAC electrical source, which must be
dedicated to the device. No other device can use this same circuit.
•
The location must be close to a floor drain. If that is impossible or if there is no floor
drain in the house, you must install a condensate pump (not supplied) in order to
eliminate condensation in a water return pipe. For example, a washing machine
return pipe could be used. Condensate pumps can be found in most hardware
stores.
•
If the air ducts are not already installed, it is preferable to plan their course before
deciding on the unit’s final location.