![Minolta DI750 - SERVICE Service Manual Download Page 259](http://html.mh-extra.com/html/minolta/di750-service/di750-service_service-manual_1802954259.webp)
4 - 55
ERROR CODE LIST
4
ELECTRIC PARTS LIST
ADU stand
motor
abnormality
Too high
fixing
temperature
abnormality
Too low
fixing
temperature
abnormality
Fixing
sensor
abnormality
F33-06
F34-01
F34-02
F34-03
F34-04
F35-01
F35-02
F36-01
F36-02
When M16 (Web drive) which has
been OFF is tur ned ON, error
detection signal (24V off) detected
blown fuse in normal condition.
TH1 (fixing temperature 1) has
detected 210°C or more five
consecutive times at intervals of 1
second.
TH3 (fixing temperature 3) has
detected 230°C or more five
consecutive times at intervals of 1
second.
Overheating (228°C or higher) was
detected for TH1 (fixing temperature
1) and TH2 (fixing temperature 2)
output voltage by the comparator
circuit.
Overheating (228°C or higher) was
detected for TH3 (fixing temperature
3) and TH4 (fixing temperature 4)
output voltage by the comparator
circuit.
TH1 (fixing temperature 1) does not
detect 50°C or higher when 180
seconds have passed since fixing ON
control started at depression of SW1
(main switch).
TH3 (fixing temperature 3) does not
detect 50°C or higher when 180
seconds have passed since fixing ON
control started at depression of SW1
(main switch).
TH1 (fixing temperature 1) has
detected 200°C or higher 30 or more
consecutive times at intervals of 1
second.
TH3 (fixing temperature 3) has
detected 220°C or higher 30 or more
consecutive times at intervals of 1
second.
If there is a paper in
copying process
when this jam occurs,
the machine stops
after completion of
copied paper ejec-
tion. RL1 (main) is
turned OFF.
The machine stops
immediately. RL1
(main) is turned OFF.
M16 (Web drive)
PRCB (printer
control board)
ACDB (AC drive
board)
L2 (fixing heater
lamp 1)
L3 (fixing heater
lamp 2)
L4 (fixing heater
lamp 3)
TH1 (fixing temper-
ature 1)
TH2 (fixing temper-
ature 2)
TH3 (fixing temper-
ature 3)
TH4 (fixing temper-
ature 4)
Main body
Warning
code
Causes
Operation in case of
warning occurrence
Estimated abnormal
parts
Classification
Di750Ver.3field04be.p65
01/07/18, 13:59
55
Summary of Contents for DI750 - SERVICE
Page 1: ...L r 3 ...
Page 6: ...CONTENTS 1 ADJUSTMENT 2 ISW 3 SERVICE 4 ELECTRIC PARTS LIST Blank page ...
Page 20: ...1 ADJUSTMENT ADJUSTMENT 1 ...
Page 21: ...1 ADJUSTMENT Blank page ...
Page 124: ...1 103 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Page 128: ...1 107 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Page 162: ...1 141 OTHER ADJUSTMENT 1 ADJUSTMENT Blank page ...
Page 163: ...2 ISW ISW 2 ...
Page 164: ...2 ISW Blank page ...
Page 177: ...3 SERVICE SERVICE 3 ...
Page 178: ...3 SERVICE Blank page ...
Page 180: ...3 SERVICE Blank page ...
Page 203: ...4 ELECTRIC PARTS LIST ELECTRIC PARTS LIST 4 ...
Page 204: ...4 ELECTRIC PARTS LIST Blank page ...
Page 213: ...4 9 PARTS LAYOUT DRAWING 4 ELECTRIC PARTS LIST Blank page ...
Page 227: ...4 23 CONNECTOR LAYOUT DRAWING 4 ELECTRIC PARTS LIST Blank page ...
Page 233: ...4 29 JAM CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Page 246: ...4 42 JAM CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Page 276: ...4 72 ERROR CODE LIST 4 ELECTRIC PARTS LIST Blank page ...
Page 279: ......