96
3. Status Information
Inputting the command “Z” will cause the present settings and status of the CA-100Plus to be output as a 134-
character word as shown below.
Format: display mode SYNC mode memory channel number and ID label analog display range
luminance unit probe connector number for display probe connector number for output calibration mode
on/off in analyzer mode WRGBvalues input status delimiter
Content
Display mode
SYNC mode
Memory channel
number and ID label
Analog display range
Luminance unit
Probe connector
number for display
Probe connector
number for output
Calibration mode on/
off in analyzer (RBG)
display mode
WRBG values input status
Number of
characters
13
12
19
24
15
11
14
10
16
Format
MODE : xyLV _ _ _ _ _ (For xyLV display mode)
MODE : T
∆
uvLV _ _ _ (For T
∆
uvLV display mode)
MODE : RGB _ _ _ _ (For analyzer (RBG) display mode)
In example, display mode is set to analyzer (RBG) display mode.
SYNC : NTSC _ _ _ (For NTSC mode)
SYNC : PAL_ _ _ _ (For PAL mode)
SYNC : EXT_ _ _ _ (For EXT mode)
SYNC : UNIV _ _ _ (For UNIV. mode)
In example, SYNC mode is set to NTSC.
CH memory channnel number [ ID label ] _ _ _
Memory channel number: Two characters
ID label: Ten characters
In example, memory channel 01 is selected and ID label is “MINOLTA”.
RANGE _ xy : range % _ _ Lv : range % _ _ _ (For xyLv or T
∆
uvLv display mode)
RANGE _ _ G : range % _ RB : range % _ _ _ (For analyzer (RBG) display mode; G standard)
RANGE _ _ R : range % _ GB : range % _ _ _ (For analyzer (RBG) display mode; R standard)
Range: Three characters; if actual value fewer than three characters, value will
be preceded by required number of spaces.
In example, analog display range for R is set to1.0% and the range for B and G is set to 2.0 %.
LUMI. : cd/m*m _ _ _ (For cd/m
2
)
LUMI. : fL _ _ _ _ _ _ _ (For fL)
In the example, the luminance unit is fL.
DISP - P : probe connector number for display _ _ _
Probe connector number for display: One character; 1 to 5
In example, probe connector number P1 was selected for display.
OUT - P : probe connector number for display _ _ _
Probe connector numbers for output: Up to five characters; 1 to 5; if fewer than
five characters, remaining characters will be spaces.
In example, probe connector numbers P1, P3, and P5 were selected for output.
CAL : ON_ _ _ _ (If calibration mode on)
CAL : OFF_ _ _ (If calibration mode off)
In example, calibration mode for analyzer mode is on.
W: # _ R : # _ G : # _ B : # _
# : * if value has already been input;_ if value has not been input yet
In example, values for W, R, and B have been input but value for G has not been input yet.
*1: Calibration mode on/off in analyzer (RBG) display mode will be output only when analyzer (RBG) display mode is set.
*2: WRBG values input status will be output only when calibration mode is on in analyzer (RBG) display mode.
[Output Example]
Display mode: Analyzer (R reference)
SYNC Mode: NTSC Memory channel: 1
ID name: MINOLTA
Range setting: 1.0% for R, 2.0% for GB
Intensity unit: fL
Display probe nos.: 1 Output probe nos. : 1, 3, 5
When analyzer CAL is ON and data for W, R and B only is input
•
In the following, “_” indicates a space.
Example: MODE : RGB _ _ _ _ _ SYNC : NTSC_ _ _ CH01 [MINOLTA _ _ _ ] _ _ _ RANGE _ _ R : 1.0% _ GB : 2.0% _ _ _ LUMI. : f
L _ _ _ _ _ _ _ DISP - P : 1 _ _ _ OUT - P : 135 _ _ _ _ _CAL : ON_ _ _ _ W : * _ R : * _ G : _ _ B : * _ delimiter
*1
*2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for CA-100PLUS -
Page 25: ...22 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 47: ...44 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 101: ...98 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 124: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...