SMART 216 / 232
27
22.3 Power management hotkey – left Shift, F12
To power manage a server connected to a power management switch:
1. Navigate to the computer line you desire to power manage.
2. Press left
Shift
,
F12
. The Power Control dialog box appears, see Figure 28.
Note
! If you change the OSD hotkey from
Shift
,
Shift
to
Ctrl
,
Ctrl
, then the
power management hotkey becomes left
Ctrl
,
F12
.
Figure 28 Power Control dialog box
3. Use the arrow keys to navigate up and down and press
Enter
to select
the power option.
4. A prompt appear, see Figure 29. Select the desired option and press
Enter
. The power command is sent.
Figure 29 Power
prompt
22.4 Moving the Confirmation label – F1
The Confirmation label appearing for 30 seconds showing which computer is
currently accessed can be positioned anywhere on the screen.
To position the label from the
Main
window:
1. Navigate to a computer line using the
Up
and
Down
arrow keys.
2. Press
F1
. The selected screen image and Confirmation label appear.
3. Use the arrow keys to move the label to the desired position.
4. Press
Esc
to save and exit.
Summary of Contents for Minicom Smart 216