Using the 6.5mm screwdriver, carefully lever the coil retainer cover (1) off the
coil top and remove it.
Figure 37 Removing the Coil Retainer
•
Remove the lower shaft with lower camlock assembly from the coil top.
•
Carefully pull the coil cable out from inside the shafts.
•
Carefully lever the skid plate off the coil using the 6.5mm screwdriver.
Note:
If there is any damage to the coil or coil cable, the coil must be replaced.
There are no repairable parts of the coil.
3.5.2. Coil Refit:
•
Refit the skid plate by pushing it onto the coil.
•
Ensure that the lower camlock assembly is completely reassembled.
•
Connect the coil cable puller to the coil plug.
Figure 38 Coil with Coil Puller attached (1)
Figure 39 Coil with Coil Puller attached (2)