4
−
2. Note on connections
Warning
●
Keep strictly to the following items in the connection with the
instrument. If neglected, it may cause an unexpected faulty or a
damage in the instrument.
D
Turn the power supply OFF when connection is made.
D
Since the terminals at the front side of the instrument is made of resin, take care not to
drop it down nor apply strong impact.
D
Recommended torque to tighten the terminal screws for terminals is 0.8 N
・
m at maximum.
D
The crimp
−
type terminal lugs for the terminals of the instrument are to be applied as
follows
:
Width of crimp
−
type terminal lugs
Suitable crimp
−
type terminal lugs
6.0 mm or less
1.25
−
3 or Y type 1.25
−
3.5
D
Keep the connecting cable with the instrument away from the noise source like power
supply line and I/O line for control as far as possible.
D
Conduit wiring should be the type of exclusive one, and avoid using with another line
together.
D
All of the connections should be executed securely according to the Instruction manual.
Summary of Contents for CSA-507C