51
9-19 Codabar
Read:
Format
Start
Data digits (variable)
Check digit (optional)
End
Check digit verification: The check digit is made as the sum module 16 of the numerical values of all data
digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code ID setting: Refer to Code ID setting of
Insertion group selection: Refer to Insertion group selection of
Start/End type: Codabar has four pairs of Start/End pattern; you may select one pair to match your
application.
Start/End transmission: Refer to Start/End transmission of
Start/End character equality: By setting Enable, the start and end character of a Codabar barcode must
be the same.