13
Installation
Line fusing
Connect an external fuse between the drive and master stop
switch as shown in Figure 6 (page 14). Install the switch
between the external fuse and AC or DC power input as shown.
Place a line fuse on +VDC if using DC input voltage, or AC1
if using AC line voltage. Refer to Table 1 (page 7) for
replacement line fuse sizes.
Power switch
Warning
Minarik strongly recommends the installation of a master
power switch in the voltage input line. The switch
contacts should be rated at a minimum of 200% of motor
nameplate current and 250 volts.
Install a master power switch in the voltage input line, as
shown in Figure 6 (page 14). The switch contacts should be
rated at a minimum of 200% of motor nameplate current and
250 volts.