Installation
BOSS-1Q terminal connections
Warning
Do not install, rewire, or remove this control with
input power applied. Doing so may cause fire or serious
injury. Make sure you have read and understood the
Safety Warnings before attempting installation.
ENABLE/DISABLE switch
Connect a single-pole, single-throw switch between the COM
and ENABLE terminals (terminals 1 and 2) of TB501 as shown
in Figure 9. Close the switch to coast the motor to a stop.
Open the switch to accelerate to set speed.
RUN/BRAKE switch
Connect a single-pole, single-throw switch between the COM
and RUN/BRAKE terminals (terminals 1 and 3) of TB501 as
shown in Figure 9. Open the switch to brake the motor to a
stop. Close the switch to accelerate to set speed.
FWD/REV switch
Connect a single-pole, single-throw switch between the COM
and FWD/REV terminals (terminals 1 and 4) of TB501 as
shown in Figure 9. Open the switch to run the motor in the
forward direction. Close the switch to run the motor in the
reverse direction.