Regen dump circuit
The regen dump circuit is recommended for all BOSS Series
drives. Regenerative loads may cause the bus voltage to
increase. The regen dump circuit prevents the voltage across
the bus capacitors from exceeding their voltage rating.
Connect the +BUS terminal on the regen dump circuit to the
+VDC terminal on the BOSS drive motherboard. Connect the
–BUS terminal on the regen dump circuit to the –VDC terminal
on the BOSS drive motherboard. See Figure 8 for regen dump
circuit connections.
Frequent regenerative reversing requires additional power
resistors to be added to the regen dump circuit. Contact the
Minarik factory for more assistance.
Using the dump circuit with a DC power source
If you use a DC power source and you wish to use the regen
dump circuit, you must connect the power source to the BOSS
drive AC1 and AC2 terminals as shown in Figure 8. Connect
the positive (+) lead from the DC power source to the AC1
terminal on the BOSS drive motherboard. Connect the
negative (or COM) lead from the DC power source to the AC2
terminal on the BOSS drive motherboard.
16
Installation
250-0224rev2.qxd 5/21/01 1:41 PM Page 16