3-8
Chapter 3 Setup
Setting the color fixation device
1
Press the
(MENU)
key in
Local.
2
Press
to select SETUP 1 to 4, and
press
key.
• Setup menu will be displayed.
3
Press
to select “Color fixation
device” and press the
key.
4
Press
to select the Color fixation
device and press the
key.
•
Heater
: Print-heater, Post-heater (1L/1R/2L/2R)
5
Press
to set ON/OFF, and press
the
key.
Select [ON] to display each setting.
•
Color fix.temp.
Set the temperature when fixing the color.
Setting range
: 150.0 to 200.0 °C
Setting unit
: Increments of 0.1 °C
•
Stand-by temp.
Set the temperature when standing by.
Setting range
: OFF, 100.0 to 150.0 °C
Setting unit
: Increments of 0.1 °C
•
Timer OFF
Set the time before the heater turns off
automatically.
Setting range
: OFF, 1 to 60min
•
Timer ON
Set the time before the heater turns on
automatically.
Setting range
: OFF, 1 to 12H
6
Press
to select setting item, and
press the
key.
7
Press
to select a set value, and
press the
key.
8
Press
key several times to end
the setting.
Setting of Logical Seek
The head’s operation varies depending on the Logical
Seek settings, as shown in the figure below.
1
Press the
(MENU)
key in
Local.
2
Press
to select SETUP 1 to 4, and
press
key.
• Setup menu will be displayed.
3
Press
to select “Logical Seek”,
and press the
key.
4
Press
to select the setting value,
and press the
key.
•
Set value
: Host / ON / OFF
5
Press
key several times to end
the setting.
• When Color fixation device is set to ON, Logical
Seek becomes invalid to prevent color
irregularities.
UNI-DIRECTIONAL
BI-DIRECTIONAL
UNI-DIRECTIONAL
BI-DIRECTIONAL
Media
Red arrow : Movement of head
Print area
Red arrow : Movement of head
Print area
Media
Media
Media
Movement of heads when LOGICAL seek is OFF
Movement of heads when LOGICAL seek is ON