background image

6

180

A

d

B

8. 

The distance between points I and III on wall A is 

the height deviation (d) of the tool. This distance 

should not exceed 1/8" (max.) at 33' (1/2" at 132'). 

For the Measuring distance of 2 x 66' = 132', the maxi

-

mum allowable deviation (d) is: 132' x ±1/8" ÷ 33' = ±1/2".

Vertical Leveling Accuracy

A  free  measuring  distance  of  approximately  16.5' 

between floor and ceiling on a firm surface is required 

for this check.

1. Draw a straight line on the ceiling to use as a 

reference line.

2. Securely mount the tool within 1' of the floor.  

3. 

Turn the tool to   ON.

4. Position the tool so that the bottom plumb point 

can be seen on the floor and the center of the top 

plumb point is located on the reference line on the 

ceiling. Allow the tool to self-level.

5. 

Mark the center of the top plumb point with the refer-

ence line on the ceiling (point I). Also, mark the cen

-

ter of the bottom plumb point on the floor (point II).

16.5'

6. 

Rotate the tool 180°. Align the center point of the 

laser beam directly onto the floor point II. 

7. Position the tool to align the center of the top plumb 

point onto the reference line on the ceiling. It may 

be necessary to rotate the tool slightly to align. 

Allow the tool to self-level.

8. 

Mark the center of the top plumb point on the 

reference line on the ceiling (point III).

d

9. 

The distance between points I and III on the ceiling 

is the deviation (d) of the tool. This distance should 

not exceed 1/8" (max.) at 33'.

For the Measuring distance of 2 x 16.5' = 33', the 

maximum allowable deviation (d) is: 33' x ±1/8" 

÷ 33' = ±1/8".

MAINTENANCE

WARNING

To reduce the risk of injury, always 

remove the battery before perform

-

ing any maintenance. Never disassemble the tool. 

Maintain Laser Level

Maintain tools. If damaged, have the tool repaired 

before use. Accidents may be caused by poorly 

maintained tools. 

WARNING

To reduce the risk of personal in-

jury and damage, never immerse 

your tool in liquid or allow a liquid to flow inside 

them.

Cleaning

Keep tool handles clean, dry and free of oil or grease. 

Use only mild soap and a damp cloth to clean the tool 

since certain cleaning agents and solvents are harm-

ful to plastics and other insulated parts. Some of these 

include gasoline, turpentine, lacquer thinner, paint 

thinner, chlorinated cleaning solvents, ammonia and 

household detergents containing ammonia. Never 

use flammable or combustible solvents around tools.

Cleaning the Lenses

Blow off loose particles with clean compressed air. 

Carefully wipe the surface with a cotton swab moist-

ened with water. 

Repairs

This tool has limited serviceable parts. Do not open 

housing or disassemble tool. For repairs, return the 

tool, battery pack and charger to the nearest autho-

rized service center.

ACCESSORIES

WARNING

Use  tools only with specifically 

designated accessories. Use of 

any other accessories may create risk of injury.

SERVICE - UNITED STATES

1-800-SAWDUST

 

(1.800.729.3878)

Monday-Friday, 7:00 AM - 6:30 PM CST

or visit 

www.milwaukeetool.com

Contact Corporate After Sales Service Technical Support 

with  technical,  service/repair,  or  warranty  questions. 
Email: [email protected]

Become a Heavy Duty Club Member at 

www.milwaukeetool.com to receive important 

notifications regarding your tool purchases. 

SERVICE - CANADA

Milwaukee Tool (Canada) Ltd 

1.800.268.4015

Monday-Friday, 7:00 AM - 4:30 PM CST

or visit www.milwaukeetool.ca

LIMITED  WARRANTY         USA & CANADA

Every MILWAUKEE power tool* (see exceptions below) is warranted to the 

original purchaser only to be free from defects in material and workman-

ship. Subject to certain exceptions, MILWAUKEE will repair or replace any 

part on an electric power tool which, after examination, is determined by 

MILWAUKEE to be defective in material or workmanship for a period of 

five (5) years** after the date of purchase unless otherwise noted. Return 

Summary of Contents for REDLITHIUM

Page 1: ...RATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de réduire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe leer y entender el manual ...

Page 2: ...ld by the battery charger or battery manufacturer may result in a risk of fire electric shock or personal injury TO REDUCE THE RISK OF ELECTRIC SHOCK al ways unplug charger before cleaning or maintenance DO NOT BURN OR INCINERATE BATTERY PACKS Battery may explode causing personal injury or damage Toxic fumes and materials are created when batteries are burned DO NOT CRUSH DROP OR DAMAGE battery Do...

Page 3: ... radio or televi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Consult the dealer or an experienced radio TV technician for help SPECIFICATIONS Cat No 3510 20 USB Input V...

Page 4: ...posure to jobsite conditions See Accuracy Field Check for information BATTERY WARNING To reduce the risk of fire personal injury and product damage due to a short circuit never immerse your tool battery pack or charger in fluid or allow a fluid to flow inside them Corrosive or conductive fluids such as seawater certain industrial chemicals and bleach or bleach containing products etc can cause a s...

Page 5: ...uld any deviation from listed product accuracy be found please con tact a MILWAUKEE service facility Failure to do so could result in rejection of warranty claim Influences on Accuracy Ambient temperature gradients can impact laser accuracy For accurate and repeatable results the following procedure should be conducted with the laser elevated off the ground and placed in the center of the working ...

Page 6: ...NING To reduce the risk of personal in jury and damage never immerse your tool in liquid or allow a liquid to flow inside them Cleaning Keep tool handles clean dry and free of oil or grease Use only mild soap and a damp cloth to clean the tool since certain cleaning agents and solvents are harm ful to plastics and other insulated parts Some of these include gasoline turpentine lacquer thinner pain...

Page 7: ...xceptions MILWAUKEE will repair or replace repair a REDLITHIUM USB battery or charger which after examination is determined by MILWAUKEE to be defective in material or workmanship for a period of two 2 years after the date of purchase unless otherwise noted Return of the REDLITHIUM USB battery or charger to a MILWAUKEE factory Service Center location or MILWAUKEE Authorized Service Station freight...

Page 8: ...ux ou la bouche Si jamais de produits chimiques se coulent d une batterie endommagée porter de gants en néoprène ou en caoutchouc pour se débarrasser d elle Si jamais la peau est exposée aux fluides de batteries la laver à l eau et au savon et rincer au vinaigre Si jamais les yeux sont exposés aux produits chimiques de la batterie rincer abondamment à l eau pendant 20 minutes et consulter un médec...

Page 9: ...des mesures suivantes Réorientation de l antenne réceptrice Augmentation de la distance entre le matériel et le récepteur Consulter le concessionnaire ou un technicien radio TV qualifié pour obtenir de l aide PICTOGRAPHIE Volts Courant direct RAYONNEMENT LASER NE PAS REGARDER DIRECTEMENT DANS LE FAISCEAU PRODUIT LASER DE CLASSE 2 Bus série universel USB Aimants Lire le manuel d utilisation Ampérag...

Page 10: ... vous Pour plus d informations consulter le site Web de RBRC www rbrc org ASSEMBLAGE AVERTISSEMENT Utiliser et charger unique ment les batteries re chargeables par USB REDLITHIUM avec cet outil rechargeable par USB Les batteries d autres types peuvent causer des dommages et des blessures Mise en place de la batterie 1 Faire tourner le bouchon et le retirer 2 Aligner la flèche qui se trouve dans la...

Page 11: ...as à achever un état de nivel lement c est à dire la surface de travail est 4 degrés hors du niveau réel les points du laser clignoteront vite 3 flashes par seconde Ajuster ou rajuster la surface de travail Dépannage Si l outil ne s allume pas S assurer que la batterie ait été bien mise L indicateur de charge montrera la charge restante tout fois qu elle ait été bien mise en place S assurer que la...

Page 12: ...e dis tance de mesure approximative de 2 x 5 m 16 5 dans une surface firme entre le plancher et le plafond est requise 1 Tracer une ligne droite sur le plafond qui servira en tant que ligne de référence 2 Monter fermement l outil à une distance approxi mative de 30 5 cm 1 du plancher 3 Allumer l outil en le mettant dans la position ON 4 Positionner l outil d une façon telle que le point d aplomb i...

Page 13: ... compact de 7 6 L et les niveaux laser M12 est de trois 3 ans à compter de la date d achat La période de garantie couvrant la DEL de la lampe de travail à DEL et l ampoule améliorée à DEL de la lampe de travail est une garantie à vie du produit soumise aux limitations ci dessus En cas de défaillance de la DEL ou de l ampoule à DEL pendant son utilisation normale la pièce défaillante sera remplacée...

Page 14: ...gaseosos polvo o materiales inflamables SEGURIDAD PERSONAL Nopermitaqueoperenestaherramientapersonas que no estén familiarizadas con el aparato estas instrucciones de seguridad y el manual del operador de la herramienta Esta herramienta puede ser peligrosa en manos de usuarios sin capacitación No estire el cuerpo demasiado Mantenga una posición segura y equilibrada adecuada en todo momento Esto pe...

Page 15: ...sea cui dadoso cuando utilice herramientas No es posible anticipar todas las situaciones que podrían tener un desenlace peligroso No utilice esta herramienta si no entiendeestasinstruccionesdeusoosiconsideraqueel trabajoarealizarsuperasuscapacidades comuníquese con Milwaukee Tool o con un profesional capacitado para recibir capacitación o información adicional Conserve las etiquetas y las placas n...

Page 16: ...batería La carcasa de plástico se volverá frágil y se romperá provocando un riesgo de lesión Almacene las baterías a temperatura ambiente alejadas de la humedad No almacene en lugares húmedos donde puede haber una corrosión de las terminales Al igual que con los otros tipos de batería puede haber una pérdida permanente de capacidad si la batería se almacena por periodos largos a temperaturas altas...

Page 17: ...el nivel láser de varias maneras Use los imanes incrustados para fijar el nivel láser a losmontantesdeacerodelmarco vigasdeacero etc Use la ranura de bocallave para colgar el nivel láser en la pared con un clavo o tornillo Coloque el nivel láser sobre una superficie plana Posicione el láser o montaje de pared en una su perficie estable Use el inserto roscado de 6 mm 1 4 20 y monte en un tripié Cua...

Page 18: ...ie firme entre dos paredes o estructuras A y B para esta revisión También se sugiere montar el nivel láser sobre un tripié disponible comercialmente para un fácil ajuste 1 Monte fijamente la herramienta a una distancia de 30 5 cm 1 de la pared A 2 Encienda la herramienta en ON 3 Dirija el rayo láser frontal contra la pared A más cercana y permita la autonivelación Marque el centro del punto láser ...

Page 19: ...os para los plásticos y otras piezas aisladas Algunos de estos incluyen la gasolina trementina adelgazador de barniz adelgazador de pintura solventes de limpieza con blanqueador amoniaco y detergentes caseros que contienen amoniaco Nunca use solventes inflamables o combustibles alrededor de las herramientas Limpieza de las lentes Sople las partículas sueltas con aire comprimido limpio Limpie cuida...

Page 20: ...después de la fecha de compra a menos que se indique lo contrario Al devolver la batería o cargador REDLITHIUM USB a un Centro de Servicio de la fábrica de MILWAUKEE o a una Estación de Servicio Autorizada de MILWAUKEE se requiere que el flete esté pagado por adelantado y asegurado Para fines de un envío correcto de baterías llame al 1 800 SAWDUST 1 800 729 3878 o visite www milwaukeetoolcom Se de...