background image

5

A single crimp should be centered in the middle of the crimping area. Number of crimps is a minimum. Additional crimps would not negatively affect the 

integrity of the connection so long as they are uniformly placed between the intended crimp area of the connector, typically outlined with color bands or knurls.

For the latest listing of approvals, visit milwaukeetool.com. For technical or service assistance, contact Milwaukee Customer Service at 1-800-729-3878.

ASSEMBLY

WARNING

Recharge only with the charger 

specified for the battery. For spe

-

cific charging instructions, read the operator’s 

manual supplied with your charger and battery.

Inserting/Removing the Battery

To 

remove

 the battery, push in the release buttons 

and pull the battery pack away from the tool.

To 

insert

 the battery, slide the pack into the body 

of the tool. Make sure it latches securely into place.

WARNING

Always remove battery pack before 

changing or removing accesso-

ries. Only use accessories specifically recom

-

mended for this tool. Others may be hazardous.

CAUTION

To avoid damage to the tool, do not 

operate the tool without the nest 

being fully closed and latched.

WARNING

An incomplete or faulty crimp could 

cause  a  fire.  Use  tool  only  with 

connectors for which they are rated. Tool and 

connectors must be used in an approved com

-

bination to achieve a successful operation. Im

-

proper combinations can result in a faulty crimp. 

Electric shock, fire, explosion, and property 

damage could occur.

ONE-KEY™

To learn more about the ONE-KEY™  function-

ality for this tool, please reference the Quick 

Start guide included with this product or go to 

milwaukeetool.com/One-Key.  To  download  the 

ONE-KEY™ app, visit the App Store or Google Play 

from your smart device.

ONE-KEY™ Indicator

Solid Blue

Wireless mode is active and ready 

to be configured via the ONE-KEY™ 

app.

Blinking Blue Tool is actively communicating with 

the ONE-KEY™ app.

Blinking Red

 

Tool is in security lockout and can 

be unlocked by the owner via the 

ONE-KEY™ app.

OPERATION

WARNING

To reduce the risk of arc flash,

 

electric shock and property 

damage, work on deenergized lines when 

possible. Tool is not insulated. Should work 

on energized lines be required, ensure all proper 

precautions, including those contained in NFPA 

70E, have been taken first.

Keep hands away from crimping jaws 

while  tool  is  in  use.  Fingers  could  be 

crushed. 

Always  remove  battery  pack  before  changing 

or removing accessories. Only use accessories 

specifically recommended for this tool. Others 

may be hazardous.

To reduce the risk of injury, always wear proper 

eye protection marked to comply with ANSI Z87.1.

When working in dusty situations, wear appro-

priate respiratory protection or use an OSHA 

compliant dust extraction solution.

Crimping

Before crimping:

• Inspect the crimping ram, nest and clevis for cracks 

or other damage. Do not use damaged parts. Con

-

tact a MILWAUKEE

 service facility.

Dual Rated Lugs & Splices with COPPER Wire

Anderson*

Blackburn

®

 

Burndy 

ILSCO

Panduit

Penn-Union

T&B

Splice 

Model #'s

VACS

ASP

YS-A

AS

ASN

SA

BCUA

60501-60578

Lug 

Model #'s

VACL

ATL

YA-A

YA-ATN

ACL, 2ACL, 

ACN, 2ACN, 

ALND, ALNS

LAA 

LAB

BLUA

60101-60178

60230-60278

Str Wire 

Size Range

Lugs: Total # of Crimps

Splices: # of Crimps per Side

Anderson*

Blackburn

®

 

Burndy 

ILSCO

Panduit

Penn-Union

T&B

#6 AWG

1-Splices Only

1

1

1

1

1

1

#4 AWG

1

#2 AWG
#1 AWG

1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG

250 MCM
300 MCM
350 MCM
400 MCM
500 MCM
600 MCM
750 MCM

Summary of Contents for M18 FORCE LOGIC 2877-20

Page 1: ...FORCELOGIC OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de r duire le risque de...

Page 2: ...personal injury Do not overreach Keep proper footing and bal ance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear loose clothing or jewe...

Page 3: ...re use Materials may crack or shatter Follow installation specifications as specified in Table A using an Approved Combination of con nectors and cables as indicated Other uses may causedamagetothetoo...

Page 4: ...RA L CRB L CRA 2L CRB 2L CSW CSWS LCA LCAS LCB LCC LCD BBLU BLU 54104 54123 TB 54204 54223 54850BE 54880BE 54930BE 54923BE Dual Rated Lugs Splices with ALUMINUM Wire Anderson Blackburn Burndy ILSCO Pa...

Page 5: ...duct or go to milwaukeetool com One Key To download the ONE KEY app visit the App Store or Google Play from your smart device ONE KEY Indicator Solid Blue Wireless mode is active and ready to be confi...

Page 6: ...arger in good repair by adopting a regular maintenance program Inspect your tool for issues such as undue noise misalignment or binding of moving parts breakage of parts or any other condition that ma...

Page 7: ...OTALLOW THE EX CLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THEABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANT...

Page 8: ...s outils sont quip s de dispositifs de d poussi rage s assurer qu ils sont connect s et correctement utilis s L utilisation d un collecteur de poussi re permet de r duire les dangers li s la poussi re...

Page 9: ...it ou des lunettes avec crans la t rauxpendantl utilisationoul entretiendel outil Inspectez et jetez les pi ces pr sentant des fis sures ou us es avant l utilisation Les mat riaux peuvent se fissurer...

Page 10: ...Tableau A Taille de c ble Cosses Nombre total de sertissages pissures Nombre de sertissages par c t Anderson Blackburn Burndy ILSCO Panduit Penn Union T B 6 AWG 1 Cosses seulement 1 1 1 1 1 1 4 AWG 1...

Page 11: ...L 2ACL ACN 2ACN ALND ALNS LAA LAB BLUA 60101 60178 60230 60278 Gamme de taille de c ble Cosses Nombre total de sertissages pissures Nombre de sertissages par c t Anderson Blackburn Burndy ILSCO Pandui...

Page 12: ...ravailler sur de lignes sans ten sion si possible L outil n est pas isol S il faut faire de travaux sur de lignes sous tension veuillez s assurer que toutes les pr cautions correspondantes y compris c...

Page 13: ...lace ment et un entretien p riodique de leurs pi ces pour un meilleur rendement Cette garantie ne couvre pas la r paration des pi ces due l utilisation normale de l outil y compris mais sans s y limit...

Page 14: ...n le plus proche pour l entretien sous garantie ou non de votre outil lectrique Milwaukee GARANTIE LIMIT E MEXIQUE AM RIQUECENTRALEETCARA BES TECHTRONIC INDUSTRIES garantit le produit pendant 5 ans pa...

Page 15: ...conecte el enchufe de la fuente de energ a y o quite la bater a de la herramienta el ctrica si es posible antes de realizar cualquier ajuste cambiar accesorios o almacenar las herramientas el ctricas...

Page 16: ...ramienta si no entiende estas instrucciones de uso o si considera que el trabajo a realizar supera sus capacidades comun queseconMilwaukeeToolocon un profesional capacitado para recibir capacitaci n o...

Page 17: ...BBCU BCU 54504 54523 TB 54804 54823 Nos de modelo de orejetas VHCL VHCS CTL CTL L CTL 2 LCN YA YA L YA L NT YA L 2NT YA L TC YA L 2TC YA 2L YA 2LN YA 2N YA TC YA 2TC YAZ CLN CLND CLNS CLW CLWD CRA CRB...