background image

4

5

At 5' away, spot is 6" in diameter

At 3' away, spot is 3.6" in diameter

At 1' away, spot is 1½" in diameter

ACCESSORIES

For a complete listing of accessories refer to your

 

MILWAUKEE 

Electric Tool catalog or go online to 

www.milwaukeetool.com. To obtain a catalog, con-

tact your local distributor or a service center.

WARNING 

Always remove batteries 

before changing or removing accessories. 
Only use accessories specifi cally recommend-
ed for this tool. Others may be hazardous. 

MAINTENANCE

WARNING 

To reduce the risk of per-

sonal injury and damage, never immerse 
your tool in liquid or allow a liquid to fl ow 
inside it.

WARNING 

To reduce the risk of injury, 

always remove the batteries from the tool 
before performing any maintenance. Never 
disassemble the tool. Contact a MILWAUKEE
 
service facility for ALL repairs.

Cleaning

Clean dust and debris from tool. Keep tool handles 

clean, dry and free of oil or grease. Use only mild 

soap and a damp cloth to clean the tool since certain 

cleaning agents and solvents are harmful to plastics 

and other insulated parts. Some of these include 

gasoline, turpentine, lacquer thinner, paint thinner, 

chlorinated cleaning solvents, ammonia and house-

hold detergents containing ammonia. Never use 

fl

 ammable or combustible solvents around tools.

Repairs

For repairs, return the tool to the nearest service 

center listed on the back cover of this operator's 

manual.

Maintaining Tool 

Keep your tool in good repair by adopting a regular 

maintenance program. After six months to one year, 

depending on use, return the tool to 

a MILWAUKEE

 

service facility for repairs.

If the tool does not start or operate at full power 

with new batteries, clean the contacts on the bat-

tery door. If the tool still does not work properly, 

return the tool to a 

MILWAUKEE

 service facility 

for repairs.

Cleaning the Lens

Blow off loose particles with clean compressed 

air. Carefully wipe the suface with a cotton swab 

moistened with water. 

Temperature Alarm

Press the Alarm button to turn on the alarm func-

tion. The bell icon is displayed. If the temperature 

reading is outside the preset range, the temperature 

reading will 

fl

 ash and an alarm will sound. 

Muting Alarm

Mute the alarm by pressing the 

Alarm button. The bell icon will go 

off. The temperature reading will 

continue to 

fl

 ash as long as it is 

outside the preset range.

Setting Preset Range for the Alarm

1.  To set the alarm range, pull and 

hold the trigger and then press the 

Alarm button. Repeat to toggle 

between LO and HI settings.

2.  Pull the trigger to increase the 

values, press the Alarm button 

to decrease the values. Wait 3 

seconds for the ranges to save 

and exit. 

Low Battery

When the Low Battery icon is dis-
played, change the batteries.  

MILWAUKEE

 Test & Measurement Products (includ-

ing bare tool, li-ion battery pack(s) and battery char-

ger but excluding alkaline batteries) are warranted 

to the original purchaser only to be free from defects 

in material and workmanship.  Subject to certain 

exceptions, 

MILWAUKEE

 will repair or replace any 

part on this product which, after examination, is deter-

mined by 

MILWAUKEE 

to be defective in material or 

workmanship for a period of 

fi

 ve (5) years* after the 

date of purchase.  Return the Test & Measurement 

tool and a copy of proof of purchase to the nearest 

Milwaukee Electric Tool Corporation - factory Service 

Center.  This warranty does not apply to damage that 

MILWAUKEE 

determines to be from repairs made or 

attempted by anyone other than 

MILWAUKEE

 autho-

rized personnel, misuse, alterations, abuse, normal 

wear and tear, lack of maintenance, or accidents.
*The warranty period for the LITHIUM-ION battery 

pack that ships with the Test & Measurement tool is 

two (2) years from the date of purchase.  *Alkaline 

battery that ships with Test & Measurement tool is 

separately warranted by the battery manufacturer. 

*The warranty period for a NON-CONTACT VOLT-

AGE DETECTOR – 2201 20 is one (1) year from the 

date of purchase.
Warranty Registration is not necessary to obtain the 

applicable warranty on 

MILWAUKEE

 product. The 

manufacturing date of the product will be used to de-

termine the warranty period if no proof of purchase is 

provided at the time warranty service is requested.

ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACE-

MENT REMEDIES DESCRIBED HEREIN IS A CONDITION 

OF THE CONTRACT FOR THE PURCHASE OF EVERY 

MILWAUKEE PRODUCT. IF YOU DO NOT AGREE TO THIS 

CONDITION, YOU SHOULD NOT PURCHASE THE PROD-

UCT. IN NO EVENT SHALL MILWAUKEE BE LIABLE FOR 

ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL OR PUNI-

TIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES, 

EXPENSES, LOSSES OR DELAYS ALLEGED TO BE AS A 

CONSEQUENCE OF ANY DAMAGE TO, FAILURE OF, OR 

DEFECT IN ANY PRODUCT INCLUDING, BUT NOT LIMITED 

TO, ANY CLAIMS FOR LOSS OF PROFITS. SOME STATES 

DO NOT ALLOW THE EXCLUSION OR LIMITATION OF 

INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE 

ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO 

YOU. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL 

OTHER EXPRESS WARRANTIES, WRITTEN OR ORAL. TO 

THE EXTENT PERMITTED BY LAW, MILWAUKEE DISCLAIMS 

ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITA-

TION ANY IMPLIED WARRANTY OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR USE OR PURPOSE; TO 

THE EXTENT SUCH DISCLAIMER IS NOT PERMITTED BY 

LAW, SUCH IMPLIED WARRANTIES ARE LIMITED TO THE 

DURATION OF THE APPLICABLE EXPRESS WARRANTY AS 

DESCRIBED ABOVE. SOME STATES DO NOT ALLOW LIMI-

TATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, 

SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU, THIS 

WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND 

YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM 

STATE TO STATE.

This warranty applies to product sold in the U.S.A. and Canada 

only.

TECHTRONIC INDUSTRIES' warranty is for 5 year since the 

original purchase date.

This warranty card covers any defect in material and work-

manship on this Power Tool.

To make this warranty valid, present this warranty card, 

sealed/stamped by the distributor or store where you pur-

chased the product, to the Authorized Service Center (ASC). 

Or, if this card has not been sealed/stamped, present the 

original proof of purchase to the ASC.

Call toll-free 1 800 832 1949 to fi nd the nearest ASC, for ser-

vice, parts, accessories or components.   

Procedure to make this warranty valid

Take the product to the ASC, along with the warranty card 

sealed/stamped by the distributor or store where you pur-

chased the product, and  there any faulty piece or component 

will be replaced without cost for you. We will cover all freight 

costs relative with this warranty process. 

Exceptions

This warranty is not valid in the following situations: 

a) When the product is used in a different manners from the 

end-user guide or instruction manual. 

b) When the conditions of use are not normal.

c) When the product was modifi ed or repaired by people not 

authorized by TECHTRONIC INDUSTRIES.

Note: If cord set is damaged, it should be replaced by an 

Authorized Service Center to avoid electric risks. 

 

SERVICE AND ATTENTION CENTER

Rafael Buelna No.1. 

Col. Tezozomoc Mexico, Azcapotzalco D.F.

Ph. 01 800 832 1949

IMPORTED AND COMMERCIALIZED BY:

TECHTRONIC INDUSTRIES MEXICO, .S.A. 

DE C.V.

Av. Santa Fe 481 piso 6, Col. Curz Manca. 

CP 05349, Cuajimalpa, D.F.

LIMITED WARRANTY - MEXICO, 

CENTRAL AMERICA AND CARIBBEAN

Model:

Date of Purchase:

Distributor or Store Stamp:

LIMITED WARRANTY - 

USA AND CANADA

Distance to Spot 10:1

——  Center of Spot
– – – Laser pointer (approx. 3/4" above center of spot)
         Spot size at distance indicated

Summary of Contents for Laser Temp-Gun 2265-20

Page 1: ...MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DE...

Page 2: ...y avoid contact If contact accidentally occurs flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation or burns Have your Temp Gun...

Page 3: ...ranty period for the LITHIUM ION battery pack that ships with the Test Measurement tool is two 2 years from the date of purchase Alkaline battery that ships with Test Measurement tool is separately wa...

Page 4: ...installer les piles pour la premi re fois re tirer l tiquette rectangu laire blanche se trouvant dans le compartiment des piles 3 Ins rer trois 3 piles AA tel qu illustr 4 Bien fermer la porte du com...

Page 5: ...uide s y infiltrer Entretien de l outil Garder l outil en bon tat en le soumettant un programme d entretien r gulier Apr s six mois selon l utilisation confier l outil un centre de service MILWAUKEE S...

Page 6: ...du bloc piles au lithium ion qui est fourni avec l outil d essai et de mesure est de deux 2 ans compter de la date d achat La pile alcaline qui est fournie avec l outil d essai et de mesure b n ficie...

Page 7: ...e segundos NOTA Un cambio r pido en la temperatura 5 C afecta las lecturas de la unidad Deje que la unidad alcance la temperatura ambiente antes de usarla 5 a 30 minutos dependiendo del cambio de temp...

Page 8: ...rant a para obtener la garant a correspondiente de los productos MILWAUKEE Se usar la fecha de fabricaci n del producto para determinar el per odo de garant a en caso de no presentarse el comprobante...

Page 9: ...ay Friday 7 00 AM 6 30 PM Central Time or visit our website at www milwaukeetool com Additionally we have a nationwide network of authorized Distributors ready to assist you with your tool and accesso...

Reviews: