Milwaukee Electric Tool Corp., Brook eld, WI 53005 USA

                               To reduce the 

 risk of injury, user must read 

  operator's manual. 

MILWAUKEE LOGO TO BE PRINTED WHITE,

ALL OTHER "WHITE" TEXT AND GRAPHICS TO

BE BASE STOCK MATERIAL

      CAT.NO. 2621-20       SER.

     

-1

(

)

 

18 V       n 0 - 3 000 min. SPM

0

®

SAWZALL

RECIPROCATING SAW

Professionally made in China by 

Milwaukee Electric Tool, PRC

G55A

CAT. NO. 48-22-8520                                     120V~                                              SER.

46 ROLLING STEEL 

"

STORAGE CABINET 

Milwaukee Electric Tool Corp., Brook eld, WI  53005 USA

Made in Vietnam

CAT. NO. 48-22-8560                                                                                      SER. H25A                                                                                  BATCH: 

40 MECHANIC’S CART 

Milwaukee Tool, Brook eld, WI  53005

Made in Vietnam

A

MILWAUKEE LOGO TO BE PRINTED WHITE,

ALL OTHER "WHITE" TEXT AND GRAPHICS TO

BE BASE STOCK MATERIAL

  Do not open more than one drawer at a

 

 

time. Station may tip, causing injury.

    

 

 

Lock wheels when station is not 

 

  being moved. Unlocked wheels can

    

allow the station to move

   unexpectedly.
 

WARNING

Milwaukee Electric Tool Corp., Brookfield, WI 53005 USA

                               To reduce the 

 risk of injury, user must read 

  operator's manual. 

MILWAUKEE LOGO TO BE PRINTED WHITE,

ALL OTHER "WHITE" TEXT AND GRAPHICS TO

BE BASE STOCK MATERIAL

      CAT.NO. 2621-20       SER.

     

-1

(

)

 

18 V       n  0 - 3 000 min. SPM

0

®

SAWZALL

RECIPROCATING SAW

Professionally made in China by 

Milwaukee Electric Tool, PRC

G55A

CAT. NO. 48-22-8520                                     120V~                                              SER.

46  ROLLING STEEL 

"

STORAGE CABINET 

Milwaukee Electric Tool Corp., Brookfield, WI  53005 USA

Made in Vietnam

CAT. NO. 48-22-8560                                                                                      SER. H25A                                                                                  BATCH: 

40 MECHANIC’S CART 

Milwaukee Tool, Brookfield, WI  53005

Made in Vietnam

A

MILWAUKEE LOGO TO BE PRINTED WHITE,

ALL OTHER "WHITE" TEXT AND GRAPHICS TO

BE BASE STOCK MATERIAL

  Do not use drawers as steps. Station

 

 

may tip, causing injury.

  

 

FPO 

  Lock all drawers before moving the station.

 

WARNING

Milwaukee Electric Tool Corp., Brookfield, WI 53005 USA

                               To reduce the 

 risk of injury, user must read 

  operator's manual. 

MILWAUKEE LOGO TO BE PRINTED WHITE,

ALL OTHER "WHITE" TEXT AND GRAPHICS TO

BE BASE STOCK MATERIAL

      CAT.NO. 2621-20       SER.

     

-1

(

)

 

18 V       n  0 - 3 000 min. SPM

0

®

SAWZALL

RECIPROCATING SAW

Professionally made in China by 

Milwaukee Electric Tool, PRC

G55A

CAT. NO. 48-22-8520                                     120V~                                              SER.

46  ROLLING STEEL 

"

STORAGE CABINET 

Milwaukee Electric Tool Corp., Brookfield, WI  53005 USA

Made in Vietnam

CAT. NO. 48-22-8560                                                                                      SER. H25A                                                                                  BATCH: 

40 MECHANIC’S CART 

Milwaukee Tool, Brookfield, WI  53005

Made in Vietnam

A

MILWAUKEE LOGO TO BE PRINTED WHITE,

ALL OTHER "WHITE" TEXT AND GRAPHICS TO

BE BASE STOCK MATERIAL

 

Unplug power strip before moving the    

   station.

FUNCTIONAL DESCRIPTION

6

1. Top tray frame

2. Tooling cup

3. Fold-out work tray

4. Side handle

5. Grommet

6. Power strip

7.  Cord storage  

brackets

3

5

8. Post

9. Bumper

10. Storage tray

11. Swivel caster with 

brake

12. Bottom tray frame

13. Rigid caster

14. Storage bar

9

10
11

4

7

8

13

14

1

12

2

GROUNDING

WARNING

Improperly connecting the ground-

ing wire can result in the risk of 

electric shock. Check with a qualified electrician 

if you are in doubt as to whether the outlet is 

properly grounded. Do not modify the plug pro-

vided with the station. Never remove the ground-

ing prong from the plug. Do not use the station 

if the cord or plug is damaged. If damaged, have 

it repaired before use. If the plug will not fit the 

outlet, have a proper outlet installed by a qualified 

electrician.

Stations  with Three Prong Plugs

Stations  marked  “Grounding  Required”  have  a 

power strip with a three wire cord and three prong 

grounding plug. The plug must be connected to a 

properly grounded outlet (See Figure A). If the  

power strip should electrically malfunction or break 

down, grounding provides a low resistance path to 

carry electricity away from the user, 

Fig. A

reducing the risk of electric shock.

The grounding prong in the plug is 

connected through the green wire 

inside the cord to the grounding sys-

tem in the power strip. The green wire in the cord 

must be the only wire connected to the power strip's 

grounding system and must never be attached to an 

electrically “live” terminal.

Your power strip must be plugged into an appropriate 

outlet, properly installed and grounded in accordance 

with all codes and ordinances. The plug and outlet 

should look like those in Figure A.

ASSEMBLY

CAUTION

Be sure to follow the assembly in

-

structions for the appropriate sta-

tion. Do not use power tools to assemble station. 

Tighten bolts with hand wrenches.

Tools Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phillips 

screwdriver

Safety 

goggles

10 mm 

Wrench

13 mm 

Wrench

Hardware Included

NOTE:

 Items not shown to actual size. Hardware 

lengths are approximate.

Hardware

Item

Description

Quantity

AA

Screw M6 x 16L

40

BB

Screw M8 x 18L

16

CC

Washer  

M19 x 8.5 x 2

16

DD

Screw M4 x 12L

8

EE

Screw M6 x 25L

2

Summary of Contents for 48-22-8590

Page 1: ...OR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de réduire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe leer y entender el manual ...

Page 2: ... be located in a recessed area or below floor level Station plugs must match the outlet Never mod ify the plug in any way Do not use any adapter plugs with earth grounded chest cabinet power strips Unmodified plugs and matching outlets will reduce risk of electric shock Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk ...

Page 3: ...et is properly grounded Do not modify the plug pro vided with the station Never remove the ground ing prong from the plug Do not use the station if the cord or plug is damaged If damaged have it repaired before use If the plug will not fit the outlet have a proper outlet installed by a qualified electrician Stations with Three Prong Plugs Stations marked Grounding Required have a power strip with ...

Page 4: ...GG and one nut HH per side OO EE FF NN GG HH FF Nylon Washer M18 x 8 5 x 1 5 4 GG Washer M12 x 6 x 0 8 2 HH Nut M6 2 II Screw M4 x 16L 12 JJ Bolt with Plastic M6 1 KK Cord Storage Bracket 2 LL Rubber Bumper 6 MM Swivel Caster with Brake 2 NN Rigid Caster 2 OO Hexagonal Head Bolt M6 x 25L 2 Installing the Frame 1 Ensure all station drawers are securely locked into place using the key lock on the st...

Page 5: ...outlet can be used to charge any device that uses less than 2 1A of DC electrical current NOTE Any device that uses more than 2 1 A of DC electrical current will trip a self resetting overload and disable the output OPERATION WARNING To avoid injury or property damage do not exceed maximum drawer capacity Use care when moving the station on incline or rough surface Station may tip if weight is not...

Page 6: ... lift empty the station and then place straps or forks inside and next to casters Do not lift loaded stations Never lift by the side handle Be sure all bystanders are moved away before lifting station Mounting Chargers The station comes equipped with twelve pre installed charger mounting bosses Four are located on the right side of the top tray four on the left side of the bottom tray and another ...

Page 7: ...cabinet which after examination is determined by MILWAUKEE to be defective in material or workman ship for a period of three 3 years after the date of purchase Return of the chest or cabinet to the place of purchase is required A copy of the proof of purchase should be included with the return product This warranty does not apply to damage that MILWAUKEE determines to be from repairs made or attem...

Page 8: ... déplacer rendant les poste de travail instable Ne pas utiliser les tiroirs comme escabeau Ne pas monter sur les poste de travail Les poste de travail peut basculer entraînant des blessures Ne pas marcher sur l étagère latérale L étagère peut s écrouler ou se casser Les poste de travail peut basculer et causer des blessures Ne pas utiliser les poste de travail dans un envi ronnement explosif par e...

Page 9: ...eau supérieur 136 0 kg 300 lbs Capacité du tiroir supérieur 45 4 kg 100 lbs Capacité du plateau inférieur 90 7 kg 200 lbs Capacité de l étagère pivotant 22 7 kg 50 lbs Capacité du plateau de rangement 22 7 kg 50 lbs Capacité totale 317 5 kg 700 lbs Volts d entrée CA 120 Hertz 60 Ampères 15 Tension du port USB 5 Watt du port USB 10 5 Intensité de courant du port USB 2 1 Température ambiante de fonc...

Page 10: ... avec la station 2 Mettre le cadre du plateau inférieur par terre Utiliser le matériel d emballage pour protéger la finition 3 Attacher les poteaux au cadre inférieur un à la fois en utilisant quatre vis AA pour chaque poteau REMARQUE Aligner les poteaux d une façon telle que ceux à la face inférieure ont quatre trous tandis que ceux à la face supérieure ont six AA x4 4 Mettre le cadre du plateau ...

Page 11: ...ttacher chaque plateau de rangement en les agra fant sur les rainures dans les poteaux Les plateaux pourront être installés dans n importe quel côté de la face intérieure ou extérieure des poteaux Installation de la barre de rangement 1 Enlever le boulon JJ de la barre de rangement 2 Faire passer la barre de rangement à travers de n importe quelles rainures sur le poteau désiré comme indiqué ci de...

Page 12: ...tes enfoncer avec le pied les leviers marqués ON S assurer de verrouiller les tous roulettes pour empêch er le mouvement ou le pivot ement du poste de travail Pour déverrouiller les rou lettes enfoncer avec le pied les leviers marqués OFF Déplacement du poste de travail sur une surface inclinée ou rugueuse S assurer que les poste de travail ne bascule pas ou ne soit pas déséquilibré lorsqu il est ...

Page 13: ...aute qualité Points de graissage Entretien des tiroirs 1 Nettoyer des tiroirs avec un détergent doux et de l eau 2 Retirer la graisse et l huile dans le tiroir avec un liquide de nettoyage ininflammable standard 3 L utilisation de revêtements de tiroir est recomman dée pour protéger la finition à l intérieur des tiroirs et faciliter leur nettoyage Les revêtements de tiroir peuvent être nettoyés av...

Page 14: ...MITATION CI DESSUS PEUT DONC NE PAS S APPLIQUER À VOUS LA PRÉSENTE GARANTIE VOUS DONNE DES DROITS JURIDIQUES SPÉCIFIQUES ET VOUS POUVEZ ÉGALEMENT AVOIR D AUTRES DROITS QUI VARIENT D UN ÉTAT À UN AUTRE La présente garantie est uniquement applicable aux produits vendus aux États Unis et au Canada Veuillez consulter le centre de service Trouver un service dans la section Service et Pièces du site Web...

Page 15: ...ciales en instalaciones res idenciales Este equipo genera utiliza y puede radiar energía de radiofrecuencia y si no se instala y utiliza en conformidad con las instrucciones puede generar interferencia perjudicial para la radiocomunicación No obstante no se garantiza que no se produzca interferencia en una instalación concreta Si este equipo en efecto genera interferencia perjudicial para la recep...

Page 16: ...AND GRAPHICS TO BE BASE STOCK MATERIAL Desconecte el conector múltiple antes de mover la estación DESCRIPCION FUNCIONAL 6 1 Marco de la charola superior 2 Recipiente para herramientas 3 Charola abatible de trabajo 4 Manija lateral 5 Ojal 6 Conector múltiple 7 Soporte para almacenamiento del cable 3 5 8 Poste 9 Protector 10 Charola de almacenamiento 11 Rueda pivotante con freno 12 Marco de la charo...

Page 17: ... con freno a la estación usando cuatro tornillos BB y arandelas CC por rueda Las ruedas pivotantes con freno deben instalarse en el extremo de la estación con el conector múltiple y la manija lateral 2 Monte las dos ruedas rígidas al extremo opuesto de la estación usando cuatro tornillos BB y arandelas CC por rueda 3 Apriete todos los pernos firmemente con una llave 4 Regrese la estación a su posi...

Page 18: ...a capacidad máxima de los anaqueles Tenga cui dado al mover la estación de trabajo en una pendiente o superficie áspera La estación de trabajo puede volcarse si el peso no está distri buido uniformemente del frente hacia atrás y de lado a lado Coloque más de la mitad del peso de carga total en la estación de trabajo inferior cuando sea posible El uso de la bandeja inferior a bandeja inferior se pu...

Page 19: ... M18 y M12 así como cargadores M18 Para montar un cargador instale un tornillo DD en cadabarra luegodeslicelasranurasenformadeojode cerraduradelcargadorsobrelostornillos Desliceelcar gador hacia el piso para bloquearlo sobre los tornillos NOTA Incluye cuatro tornillos DD para los mon tajes para cargador DD Cómo retirar los cajones 1 Extienda por completo y vacíe el cajón 2 Dependiendo del lado lev...

Page 20: ...indebido alteraciones maltrato desgaste normal falta de mantenimiento o accidentes No se requiere el registro de la garantía para obtener la garantía cor respondiente de una caja o gabinete de almacenamiento MILWAUKEE La fecha de manufactura del producto se utilizará para determinar el periodo de garantía si no se proporciona comprobante de compra al solicitar el servicio en garantía Si considera ...