background image

3

GROUNDING

DANGER

Improperly connecting the ground-

ing wire can result in the risk of 

electric shock. Check with a qualified electrician if 

you are in doubt as to whether the outlet is prop

-

erly grounded. Do not modify the plug provided 

with the tool. Never remove the grounding prong 

from the plug. Do not use the tool if the cord or 

plug is damaged. If damaged, have it repaired by a 

MILWAUKEE service facility before use. If the plug 

will not fit the outlet, have a proper outlet installed 

by a qualified electrician.

Double Insulated Tools (Two-Prong Plugs)

Tools marked “Double Insulated” do not require ground-

ing. They have a special double insulation system which 

satisfies OSHA requirements and complies with the 

applicable standards of Underwriters 

Fig. B Fig. C

Laboratories, Inc., the Canadian Stan

-

dard Association and the National Elec-

trical Code. Double Insulated tools may 

be used in either of the 120 volt outlets 

shown in Figures B and C. 

SPECIFICATIONS

Cat. No. .................................................... 2155-AC

AC Input Volts

 ............................................ 120-277

AC Input Watts

 ....................................................

70

AC Output Volts ......................................... 120-277

Max Terminal Block Ampacity

 ..............................30

Wiring

 ....................... Romex and MC, 14-2 to 10-3

Consult with Local and National Electrical Codes

FUNCTIONAL DESCRIPTION

1. 

Wiring Cover

2. 

Cover screw

3. 

Cable

4. 

Wire clamps

5. AC input/output

6. 

Cable clamp

7. 

LED cover

1

2

3

4

5

7

6

SYMBOLOGY

 

   Volts

 

  Alternating Current

 

  Electrical Shock Hazard

 

  Read Operator's Manual

 

 

CAUTION

Bright Light - 

 

 

                       

Do Not Stare Into Light 

 

  Double Insulated

 

C

US

  UL Listing for Canada and U.S.

ASSEMBLY

WARNING

To reduce the risk of injury, always 

unplug  tool  before  changing  or 

removing accessories. Only use accessories 

specifically recommended for this tool. Others 

may be hazardous.

Conversion to Permanent Wiring

WARNING! Always install light in accordance with 

local codes. 

To add lights in a chain, or replace the wiring:

1. Unplug the light.

2. Open the wiring cover by turning the cover screw 

1/4 turn counterclockwise.

3. Remove and discard old wiring.

4. To add wiring, expose 3 to 4 inches of the wires 

from the outer jacket/armor. 

5. Feed the wire through the AC input/output holes, and 

butt the outer jacket/armor up against the wire clamps.

6. Tighten the wire clamps using the clamping screws. 

Hand tighten wire clamp screws securely to 8 lb-in.

7. Wire the lamp according to the diagrams below. 

Use one side for wiring to the AC plug, and the 

other for wiring to another lamp in a chain. Hand 

tighten terminal block screws securely to 10 lb-in.

8. 

Close the wiring cover and secure by turning the 

cover screw 1/4 turn clockwise.

Strain 

Relief

AC Input/

Output Holes

Wire 

clamps

Clamping 

screws

Summary of Contents for 2155-AC

Page 1: ...OR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de r duire le risque de blessures l util...

Page 2: ...C permitted in box Suitable for Types NM and MC cable only Always install light in accordance with local and national codes CAUTION Do not use in hazardous locations as required by the Canadian Electr...

Page 3: ...N 1 Wiring Cover 2 Cover screw 3 Cable 4 Wire clamps 5 AC input output 6 Cable clamp 7 LED cover 1 2 3 4 5 7 6 SYMBOLOGY Volts Alternating Current Electrical Shock Hazard Read Operator s Manual CAUTIO...

Page 4: ...g date of the product will be used to determine the warranty period if no proof of pur chase is provided at the time warranty service is requested ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT RE...

Page 5: ...lectrocution un incendie ou des blessures graves Conserver les r gles et les instructions des fins de r f rence ult rieure S CURIT DU LIEU DE TRAVAIL Pour r duire les risques de blessures porter une...

Page 6: ...ations importantes y fig urent Si elles sont illisibles ou manquantes contacter un centre de services et d entretien MILWAUKEE pour un remplacement gratuit PICTOGRAPHIE Volts Courant alternatif Danger...

Page 7: ...10 10 14 12 10 10 12 10 12 Bas sur sur une chute de voltage limite de 5 volts 150 de l intensit moyenne de courant LISEZ ATTENTIVEMENT CES INSTRUCTIONS ET CONSERVEZ LES POUR LES CONSULTER AU BESOIN MO...

Page 8: ...ampe de travail est une garantie vie du produit soumise aux limitations ci dessus En cas de d faillance de la DEL ou de l ampoule DEL pendant son utilisation normale la pi ce d faillante sera remplac...

Page 9: ...de descarga el ctrica Mantengaloscablessecosyalejadosdelpiso Aco mode los cables cuidadosamente para evitar entor nos peligrosos Tropezarse o atorarse en los cables puede causar lesiones y da o al pro...

Page 10: ...INSTRUCCIONES PARA FUTURAS REFERANCIAS ESPECIFICACIONES Cat No 2155 AC Voltios de la entrada CA 120 277 Vatios de entrada CA 70 Voltios de salida CA 120 277 Bloque de terminales m ximo ampacidad 30 C...

Page 11: ...tes in flamables o combustibles cerca de una herramienta Reparaciones Si su herramienta se da a vuelva la herramienta entero al m s cercano centro de reparaciones ACCESORIOS ADVERTENCIA Utilice s lo l...

Page 12: ...O EN LA MEDIDAEN QUE DICHO DESCONOCIMIENTO NO SEAPERMITIDO POR LA LEY DICHAS GARANT AS IMPL CITAS SE LIMITAN A LA DURACI N DE LA GARANT A EXPRESA CORRESPONDIENTE SEG N SE DESCRIBI ANTERIORMENTE ALGUNO...