54
APPENDEX A
A.1 MAXROY B PUMP ECC FIELD INSTALLA-
TION (RETROFIT) (FIGURE 19)
This section applies to field mounting the ECC on a
manually adjusted maxRoy pump. Refer to Figure
8 in manual 3390005000. Installing the ECC to a
maxRoy B pu mp re quires me chanically m ounting
the ECC and performing the ECC calibration pro-
cedures.
1. Remove n
ameplate (F
igure 8
, BN
,
3390005000) from capacity control knob (BO)
exposing th e keyway so cket in th e top of th e
knob. Adjust knob to 100% capacity setting.
2. Leave stroke locking handle (BK) loose.
3. Mount bracket onto pump housing 3 bolts and
lockwashers (Figure 19, 830 & 835).
4. Assemble dowel pin (855) (press fit) and brass
drive pin (845) (slip fit) into the link (850). Insert
the as sembled link into th e ca pacity control
knob keyway. The drive pin side of the link fits
into the slot in the top of the knob.
5. Loosely assemble the coupling (860) and cou-
pling nut (865). Assemble the coupling to th e
link. The drive pin of the link fit s into the cou-
pling slot.
IMPROPER CONNECTION
OF THE
POWER LINE OR INCORR ECT SUPPLY
VOLTAGE CAN CAUSE DAMAGE TO
THE EC C. D ISCONNECT ALL POW ER
BEFORE CONNECTING WIRES.
6. Connect electrical connections, Paragraph 2.6.
WARNING
YOU WILL BE MAKING ADJUSTMENTS
TO THE ECC
CONTROL CIRC UIT
BOARD WHILE IT IS POWERED UP.
THIS CONTROL BOAR D IS POWER ED
BY POTEN
TIALLY
DANGEROUS
VOLTAGE (1 15 OR 230 V AC). THE
CALIBRATION PROCED URE IS TO BE
PERFORMED ONLY BY QUAL
IFIED
PERSONNEL FAMILIAR WIT
H THE
HAZARDS INHERENT WORKING NEAR
HIGH VOLT AGES. MILTON ROY
ASSUMES NO RESPONSIBILITIES FOR
DAMAGE TO EQUIPMENT OR INJU RY
TO P ERSONNEL WH ILE PER FORMING
THIS CALIBRATION PROCEDURE.
7. Perform calibration B, Paragraph 4.8.1.2.
8. Mount the ECC onto the mou nting bracket.
The ECC shaft should slip into the coupling nut
bore. (If the shaft does not slide easily into the
bore, loosen the coupling nut.) Fasten the ECC
to the bracket with the four bolts and lockwash-
ers (870 & 875).
9. Tighten the coupling nut to the coupling using
two wr enches (40 ft-lbs), bein g car eful not to
change the pump capacity setting or move the
ECC shaft.
www.motralec.com / [email protected] / 01.39.97.65.10